Skip to content

Clinical Safety and Efficacy of the VDyne Transcatheter Tricuspid Valve Replacement System for the Treatment of Tricuspid Regurgitation ( VISTA-US)

Clinical Safety and Efficacy of the VDyne Transcatheter Tricuspid Valve Replacement System for the Treatment of Tricuspid Regurgitation

Status
Recruiting
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05848284
Acronym
VISTA-US
Enrollment
30
Registered
2023-05-08
Start date
2024-04-01
Completion date
2031-11-30
Last updated
2026-03-31

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Tricuspid Regurgitation, Tricuspid Valve Disease, Tricuspid Valvular Disorders

Keywords

VDyne

Brief summary

The purpose of this clinical study is to evaluate the safety and clinical efficacy of the VDyne System in the treatment of symptomatic severe tricuspid regurgitation (TR).

Interventions

The study investigational device is the VDyne Transcatheter Tricuspid Valve Replacement System which consists of a bioprosthetic implantable tricuspid valve, the VDyne Delivery System, Drop Tether, accessories that facilitate the placement of the valve and the VDyne Retrieval System. The VDyne Valve is deployed by transfemoral implantation within the native tricuspid valve and is implanted under fluoroscopic and transesophageal echocardiography (TEE) guidance, while the heart remains beating, without the use of CPB. The valve is repositionable and fully retrievable intraoperatively. Repositioning allows optimization of the valve position following deployment, and retrieval, with the VDyne Retrieval System, allows use of an alternative valve size or removal of the index VDyne Valve in the event of suboptimal valve delivery or other intraoperative complication.

Sponsors

VDyne, Inc.
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Symptomatic severe tricuspid valve regurgitation of primary or secondary etiology. * NYHA class ≥ II. If NYHA Class IV, patient must be ambulatory. * Subject is adequately treated with medical therapy for heart failure ≥ 30 days prior to * index procedure, including a diuretic. * Heart Team determines patient is a recommended candidate for the VDyne System. * Age \>18 years at time of index procedure. * Clinical Screening Committee (CSC) and Imaging Core Labs confirm suitability for treatment with the VDyne System.

Exclusion criteria

* Patient anatomy (cardiac and vascular) is not suitable for VDyne System as assessed by Imaging Core Labs, Sponsor or Clinical Screening Committee (CSC) * Intolerance to procedural anticoagulation or post-procedural antiplatelet/ anticoagulation regimen that cannot be medically managed * Hypersensitivity to nickel or titanium * Left Ventricular Ejection Fraction (LVEF) \<30%. * Severe RV dysfunction. * Significant abnormalities of the tricuspid valve and sub-valvular apparatus. * Sepsis including active infective endocarditis (IE) (within last 6 months). * Right ventricular, atrial thrombus, vegetation or mass on tricuspid valve. * Severe tricuspid annular or leaflets calcification. * Systolic pulmonary hypertension with systolic pulmonary artery pressure \>70 mmHg. * History or rheumatic fever * Significant coronary artery disease requiring treatment such as symptomatic, unresolved multi-vessel or unprotected left main coronary artery disease. * Any planned surgery or interventional procedure within 30 days prior to or 30 days following the implant procedure. This includes any planned concomitant cardiovascular procedure such as CABG, PCI, pulmonary vein ablation, left atrial appendage occlusion, septal defect repair, etc. * Unresolved severe symptomatic carotid stenosis (\> 70% by ultrasound). * Cardiac resynchronization therapy device or implantable pulse generator implanted within 60 days of planned implant procedure. * Permanent pacing leads that will interfere with delivery or implantation of the VDyne Valve. * Cardiogenic shock or hemodynamic instability requiring inotropes or mechanical support devices at the time of planned implant procedure. * Prior tricuspid valve surgery or catheter-based therapy with permanent residual device(s) implanted that would preclude delivery or implantation of the VDyne Valve (e.g. valve replacement, edge to edge repair, etc.). * Significant valvular heart disease requiring intervention other than the tricuspid valve. * Known significant intracardiac shunt (e.g. septal defect) * Cerebrovascular accident (stroke, TIA) within 6 months of treatment procedure. * Severe lung disease (severe COPD or continuous use of home oxygen or oral steroids). * Acute myocardial infarction (AMI) within 30 days. * Significant renal dysfunction (eGFR\<30 ml/min/1.73m2) or on dialysis. * End-stage liver disease (MELD \> 11 / CHILD class C). * Bleeding requiring transfusion within prior 30 days. * Coagulopathy or other clotting disorder that cannot be medically managed. * Chronic immunosuppression or other condition that could impair healing response. * Any of the following: leukopenia, chronic anemia (Hgb \< 9), thrombocytopenia, history of bleeding diathesis, or coagulopathy. * Unwilling to receive blood products. * Known hypersensitivity or contraindication to procedural or post-procedural medications (e.g., contrast solution) which cannot be adequately managed medically. * Life expectancy less than 12 months due to non-cardiac comorbidities. * Treatment is not expected to provide benefit (futile). * Current IV Drug user (must be free drug abuse for \> 1 year). * Pregnant, lactating or planning pregnancy within next 12 months. * Vulnerable patient groups (minors, cognitively impaired persons, prisoners, persons whose willingness to volunteer could be unduly influenced by the expectation of benefits associated with participation or of retaliatory response from senior members of a hierarchy in case of refusal to participate, such as students, residents, and employees). * Currently participating in an investigational drug or device trial that has not reached its primary endpoint or is likely to interfere with this study. * Patient (or legal guardian) unable or unwilling to provide written, informed consent before study enrollment. * Patient unable or unwilling to comply with study required testing and follow-up visits

Design outcomes

Primary

MeasureTime frameDescription
The percentage of subjects with Device- and/or Procedure-related Major Adverse Events (MAE) within 30 days of the procedure, as classified by the Clinical Events Committee (CEC).Implant to 30 days post-procedureThe percentage of subjects with Device- and/or Procedure-related Major Adverse Events (MAE) within 30 days of the procedure, as classified by the Clinical Events Committee (CEC).
Change in tricuspid valve regurgitation compared to baseline as measured by the Imaging Core LabsBaseline to 1 month after implantChange in tricuspid valve regurgitation compared to baseline as measured by the Imaging Core Labs
Changes in symptom status (NYHA class)Baseline to 1 month after implantChanges in symptom status (NYHA class)
Changes in functional capacity (6-minute walk test)Baseline to 1 month after implantChanges in functional capacity (6-minute walk test)
Changes in in quality of life (KCCQ score)Baseline to 1 month after implantChanges in in quality of life (KCCQ score). A higher score indicates worsening quality of life outcomes

Secondary

MeasureTime frameDescription
The percentage of subjects with Device- and/or Procedure-related Major Adverse Events (MAE) after 30 days to 1 year of the procedure, as classified by the Clinical Events Committee (CEC).30 days post-procedure to 1 yearThe percentage of subjects with Device- and/or Procedure-related Major Adverse Events (MAE) after 30 days to 1 year of the procedure, as classified by the Clinical Events Committee (CEC).
Change in tricuspid valve regurgitation compared to baseline as measured by the Imaging Core Labs1 month after implant to 1 year post-implantChange in tricuspid valve regurgitation compared to baseline as measured by the Imaging Core Labs
Changes in right ventricle as measured by core lab1 month after implant to 1 year post-implantChanges in the right ventricle as measured by core lab
Rate of heart failure hospitalization1 month after implant to 1 year post-implantRate of heart failure hospitalization
Changes in symptom status (NYHA class)1 month after implant to 1 year post-implantChanges in symptom status (NYHA class)
Changes in functional capacity (6-minute walk test)1 month after implant to 1 year post-implantChanges in functional capacity (6-minute walk test)
Changes in in quality of life (KCCQ score).1 month after implant to 1 year post-implantChanges in in quality of life (KCCQ score). A higher score indicates worsening outcomes

Countries

Canada, United States

Contacts

CONTACTVinny Podichetty
vpodichetty@vdyne.com763-777-5969
CONTACTJeya Satheesh
jsatheesh@vdyne.com952-686-8158

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Apr 1, 2026