Skip to content

Real-time Motion Management During Prostate and Lung Radiotherapy

Real-time Motion Management During Prostate and Lung Radiotherapy

Status
Active, not recruiting
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05844761
Acronym
REMIND
Enrollment
132
Registered
2023-05-06
Start date
2023-05-01
Completion date
2027-12-01
Last updated
2026-07-28

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cancer of Lung, Cancer of Prostate, Lung Metastasis

Brief summary

The goal of this interventional non-inferiority trial is to assess the accuracy of different real-time motion management radiotherapy techniques. The main question the study aims to answer are: * What are the target margins for radiotherapy with motion management that are not inferior to target margin without motion management * What are the dosimetric and geometrical accuracy to patient for the motion management techniques. Participants will answer QoL questionary, and the accuracy of treatment will be assessed from treatment data.

Detailed description

This study will assess the feasibility of implementing real-time tracking in a clinical setting to account for the relative motion of the moving tumours localised to the prostate or lung. The capability to track the treatment target's motion will ensure that the dose prescribed by the radiation oncologist is the dose delivered to the target and minimises side effects to the critical organs. During radiation treatment, the target position will be monitored in real-time using built-in imaging technology. The radiation beam shape will be altered to compensate for the moved target positions by the treatment delivery system. The delivered dose to the patient will be calculated after the treatment and compared to the dose without real-time tracking to assess the potential benefit to treatment efficacy, recognising that the radiation dose received by tumour tissue is a very strong biomarker for response. The estimated dose distributions will be compared to the original plan for non-inferiority using the dose reconstruction method based on the prostate motion trajectory and the logged MLC positions (beam shapes). Also, the impact on organs at risk doses due to MLC target tracking.

Interventions

RADIATIONTriggered imaging on TrueBeam with margin reduction

At interim analysis the Planning target volume (PTV) will be reduced based on the accuracy of the TrueBeam triggered imaging motion management technique.

RADIATIONSynchrony MLC tracking on fiducials with margin reduction

At interim analysis the Planning target volume (PTV) will be reduced based on the accuracy of the Radixact Synchrony motion management technique.

RADIATIONSynchrony MLC tracking and lung adaptive model with margin reduction

At interim analysis the Planning target volume (PTV) will be reduced based on the accuracy of the Radixact Synchrony motion management technique for lung cancer.

Sponsors

Region Skane
Lead SponsorOTHER

Study design

Allocation
NON_RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Intervention model description

Patients will undergo radiotherapy using motion management techniques: Triggered Imaging with TrueBeam for prostate cancer, Synchrony with Radixact for prostate cancer, and Synchrony with Radixact for lung cancer. Dosimetric coverage will be assessed after treatment based on the accuracy of the motion management techniques and compared with dose coverage without motion management. After interim analysis, Planning target volume (PTV) will be reduced based on dosimetric accuracy in each arm.

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

For prostate cancer patients: * Patients histologically proven prostate adenocarcinoma * Prostate specific antigen (PSA) obtained within three months prior to enrollment * Localised prostate cancer at any stage eligible for radiotherapy: i.e. any T- or Gleason stage, but no pelvic lymph nodes can be included within the target to be treated * Eastern Cooperative Oncology Group (ECOG) performance status 0-2 * Ability to understand and the willingness to sign a written informed consent document. * Hypofractionated radiation therapy (HYPO) fractionated patients with a prescribed dose of 42.7Gy in 7 fractions. * MRIOnly workflow meaning synthetic generated CT based on Magnetic resonance imaging (MRI) * Patients over 40 years old For lung cancer patients: * Lung cancer or localised metastatic disease from other cancer diagnoses, accepted for stereotactic radiotherapy to 45Gy in 3 fractions * Lesion distinguishable on Computer Tomography and where the majority of adjacent tissue is the lung. * Ability to understand and the willingness to sign a written informed consent document. * Is able to perform treatment simulation

Exclusion criteria

For prostate cancer patients: * Patient must have three gold fiducial markers inserted in the prostate * Patients with artificial Hip(s), lumbar spinal surgical rods or other large metallic pelvic implants * Patients with overlapping implanted gold fiducials in X-ray imaging * Unfeasible to track fiducials with kv imaging/existing online imaging systems For lung cancer patients: * Previous treatment with radiotherapy for lung cancer or lung metastasis * Idiopathic lung fibrosis

Design outcomes

Primary

MeasureTime frameDescription
Dosemetric accuracyAt treatment completion, approximately 1-4 weeksDose coverage defined as dose to 99% of clinical target volume (CTV) (D99%) to target including margin for other uncertainties.

Secondary

MeasureTime frameDescription
Geometric accuracyAt treatment completion, approximately 1-4 weeksThe geometric accuracy of the beam shape, determined by comparing the ideal beam shape with the actual beam shape based on the centroid of the shape as assessed with mean absolute error (MAE)
Motion trajectoryAt treatment completion, approximately 1-4 weeksMotion trajectory measured by kilovoltage imaging, including any prediction algorithms compared to without latency and other limitations compared with MAE.
Acute ToxicityBaseline prior to first fraction. At end of radiotherapy (1-4 weeks) and at 3 months after last fraction..EORTC guided and physician assessed
Mechanical & software failureAt treatment completion, approximately 1-4 weeksThe percentage of fractions delivered without software or mechanical failure

Countries

Sweden

Contacts

PRINCIPAL_INVESTIGATORAndré Haraldsson, PhD, MPE

Skane university hospital, Lund university

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Jul 29, 2026