Skip to content

Non-Invasive MOnitoring in Transcathether Aortic Valve Implantation

Non-Invasive MOnitoring in Transcathether Aortic Valve Implantation - A Single-center, Prospective, Interventional Study With the ClearSight® Finger Cuff

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05840757
Acronym
NIMO-TAVI
Enrollment
50
Registered
2023-05-03
Start date
2023-03-31
Completion date
2023-12-31
Last updated
2024-05-14

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Aortic Valve Disease

Keywords

Transcatheter aortic valve implantation, hemodynamic parameter

Brief summary

In patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve implantation (TAVI) minimal evidence is available for invasive hemodynamic monitoring and no evidence for tools able to measure traditionally invasive parameters non-invasively for peri-procedural guidance and post-interventional management. The aim of this study is to evaluate the effectiveness and safety of a non-invasive hemodynamics monitoring tool called ClearSight for monitoring during TAVI procedures compared with standard invasive measurements.

Detailed description

In patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve implantation (TAVI) minimal evidence is available for invasive hemodynamic monitoring and no evidence for tools able to measure traditionally invasive parameters non-invasively for peri-procedural guidance and post-interventional management. The aim of this study is to evaluate the effectiveness and safety of a non-invasive hemodynamics monitoring tool called ClearSight for monitoring during TAVI procedures compared with standard invasive measurements. The ClearSight monitoring system works non-invasively by utilizing an inflatable finger cuff which adjusts automatically to measure the arterial blood pressure which enables the calculation of parameters such as cardiac output or index. Multiple studies have demonstrated the reliability and feasibility of continuous non-invasive monitoring, in different settings, however it was never performed in patients undergoing TAVI. The ClearSight monitoring system will be directly compared to invasive measurements of hemodynamic parameters during the procedure. In addition, information regarding baseline hemodynamics and its changes during/after procedure may give important information on peri- and post-procedural management and short-term outcomes and discharge planning. A tool, providing this information non-invasively with the same accuracy might result in a major improvement in daily practice..

Interventions

DEVICEHemoSphere ClearSight Module

The Clear Sight system consists of a finger cuff connected to a monitor It will be applied to the patients finger before and removed after the TAVI procedure.

Sponsors

University of Basel
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

• Adult patients (\>18 years old) with severe aortic stenosis undergoing elective TAVI.

Exclusion criteria

* Emergency indication for TAVI * Severe tricuspid regurgitation * Severe mitral stenosis or severe regurgitation * Invasive right heart catheterization impossible * Dependency on right ventricle pacing immediately after TAVI implantation * Vulnerable subjects * Known or suspected non-compliance, drug or alcohol abuse * Participation in another investigation with an investigational drug or another MD within the 30 days preceding and during the present investigation affecting this study * Previous enrolment into the current investigation

Design outcomes

Primary

MeasureTime frameDescription
Diastolic blood pressureDuring aortic valve implantation which generally takes about 40minsdiastolic blood pressure (dBP in mmHg)
Systolic blood pressureDuring aortic valve implantation which generally takes about 40minssystolic blood pressure (sBP in mmHg)
Cardiac OutputDuring aortic valve implantation which generally takes about 40minsCardiac Output (CO in L/min)
Cardiac IndexDuring aortic valve implantation which generally takes about 40minsCardiac Index (CI in L/min/m2)

Countries

Switzerland

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026