Skip to content

Safety and Efficacy of the Vascular Closure Device (Tonbridge) in Hemostasis Treatment of Femoral Artery Puncture

Safety and Efficacy of the Vascular Closure Device (Tonbridge) in Hemostasis Treatment of Femoral Artery Puncture: A Prospective, Multicenter, Randomized Controlled, Non-inferiority Trial

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05822804
Enrollment
228
Registered
2023-04-21
Start date
2023-05-22
Completion date
2024-03-01
Last updated
2025-07-23

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Endovascular Procedure, Femoral Artery, Hemostasis, Puncture, Vascular Closure

Brief summary

The purpose of this study is to verify the safety and efficacy of the Vascular Closure Device (Tonbridge) in hemostasis treatment for femoral artery puncture.

Detailed description

This is a prospective, multicenter, randomized control, non-inferiority clinical trial carried out in 7 centers throughout China. 228 subjects with hemostasis of femoral artery puncture will be treated with the Vascular Closure Device (Tonbridge) or the EXOSEAL Vascular Closure Device (Codis Corporation). The primary objective of this study is to evaluate the safety and effectiveness of the vascular closure device in hemostasis treatment for femoral artery puncture.

Interventions

DEVICEVascular Closure Device (Tonbridge)

Hemostasis treatment for femoral artery puncture with Vascular Closure Device (Tonbridge).

DEVICEEXOSEAL Vascular Closure Device (Codis Corporation)

Hemostasis treatment for femoral artery puncture with EXOSEAL Vascular Closure Device (Codis Corporation).

Sponsors

Ton-Bridge Medical Tech. Co., Ltd
Lead SponsorINDUSTRY

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

* Age 18-80, male or non-pregnant female; * Subjects undergoing unilateral femoral artery retrograde puncture for angiography or interventional procedure; * Using guide sheath ≥5F to ≤8F, and length ≤12cm in angiography or interventional procedure; * Subjects or their legal guardians voluntarily participate in this study, can complete follow-ups, and sign the informed consent form.

Exclusion criteria

* Ipsilateral common femoral artery occlusion or lumen diameter \< 5mm; * Inability to walk; * Allergy to contrast media; * Allergy to PGA or PEG; subjects with a history of common femoral artery surgery, percutaneous transluminal angioplasty (PTA), stent implantation, or vascular graft; * Subjects with bleeding tendency, such as thrombocytopenia (platelet count \<100×109/L), hemophilia, von willebrand diseases, pre-procedure INR \>1.5, etc.; * Subjects have taken anticoagulants for a long term before the procedure and have blood coagulation disorders; * BMI \>40kg/m\^2; * Subjects receive thrombolytic therapy (such as streptokinase, urokinase, t-PA) within≤24 hours before vascular closure; * Local infections or skin infections of the investigational limb; * Subjects with target femoral artery dissection or aneurysm within 30 days before intervention procedure; * Subjects with puncture site have been punctured through the posterior wall of the femoral artery, or have been punctured several times (≥3 times), or have bleeding or hematoma on the femoral artery puncture site during the procedure; * Subjects with clinically significant peripheral vascular diseases (such as severe calcification, arteritis, stenosis, etc) near the puncture site; * Women who are pregnant or breastfeeding, OR men or women who plan to have a child in the next 6 months; * Subjects who are enrolled in other clinical trials and don't complete; * Subjects are considered not suitable for enrollment by the investigators.

Design outcomes

Primary

MeasureTime frameDescription
Immediate hemostasis success rateintra-procedureImmediate hemostasis success is defined as no significant blood oozing and no visible or palpable expanding or developing hematoma on femoral artery puncture site within 5 minutes, once completing the closure operation of femoral artery puncture site using vascular closure device.

Secondary

MeasureTime frameDescription
Incidence of serious adverse events (SAE)30±7 days post-procedureIncidence of serious adverse events is the proportion of subjects with serious adverse events using the investigational device or the comparator.
Time to hemostasisintra-procedureThe time it takes (unit: minute) to reach no significant blood oozing and no visible or palpable expanding or developing hematoma on femoral artery puncture site, once completing the closure operation of femoral artery puncture site using vascular closure device.
Incidence of complications associated with femoral artery access30±7 days post-procedureIncidence of complications associated with femoral artery access is the proportion of subjects with femoral artery access complications using the investigational device or the comparator.
Incidence of device deficiencyintra-procedureDevice deficiency is the unreasonable risk that may endanger human health and life safety under normal use of medical devices during clinical trials, such as labeling errors, quality problems and malfunctions, etc.
Incidence of adverse events (AE)30±7 days post-procedureIncidence of adverse events is the proportion of subjects with adverse events using the investigational device or the comparator.

Countries

China

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026