Skip to content

Family Support Weaning from Mechanical Ventilation in Cardiovascular Surgery

The Effect of Family Support on Hemodynamic Parameter, Comfort and Anxiety Level in Weaning from Mechanical Ventilation in Cardiovascular Surgery: a Randomized Controlled Study

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05820789
Enrollment
40
Registered
2023-04-20
Start date
2023-04-30
Completion date
2024-04-20
Last updated
2025-03-06

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Anxiety, Patient Comfort, Patient Satisfaction

Keywords

Weaning, Patient satisfaction, Anxiety, Family support, Cardiac surgery

Brief summary

Mechanical ventilation support is used to ensure airway clarity in patients after surgery.If patients are not informed about mechanical ventilation treatment in the pre -operation period, panic, anxiety and comfort may be experienced when they wake up from anesthesia and find them in intensive care under mechanical ventilation with various tubes and equipment. The separation from the mechanical ventilator (MV) covers the patient's mechanical support and the entire process of separation of endotrakeal tube.During the separation of the mechanical ventilator, the support of one of the patient members of the patient may increase the stress and comfort of the patient. Therefore, this research is planned

Detailed description

Intensive care nurses spend a long time with patients and observe them closely. Intensive care nurses in the MV separation process; plays a special and important role. Recently, family support has been used in patient care. An increase in anxiety and comfort levels is observed in patients receiving family support. This study was planned with the aim of supporting the patient by the family member during the separation of the patient from the mechanical ventilator after cardiac surgery and to evaluate the comfort and anxiety level of the patients.

Interventions

Before the extubation procedure, the patient's relatives will be informed, and the patient will be allowed to enter the intensive care unit, and the patient will be able to express that he is with the patient by holding his hand and talking.

Sponsors

Kastamonu University
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
PARALLEL
Primary purpose
OTHER
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

* Volunteering to participate in the research * To agree to participate in the research verbally and in writing * To be over the age of 18 * Knowing Turkish * Not having any psychiatric disease * No vision, hearing and perception problems * Receiving mechanical ventilator support after cardiac surgery and being followed in the intensive care unit.

Exclusion criteria

* Patients who do not meet the inclusion criteria * Other patients receiving mechanical ventilator support after surgery in the intensive care unit other than cardiac surgery

Design outcomes

Primary

MeasureTime frameDescription
Oxygen saturation (SpO2) - after weaning 410 miniutes after weaning procedureOxygen saturation (SpO2)
State Anxiety30 minutes before the weaning procedure.State Anxiety Inventory was used to assess state anxiety. The Turkish validity and reliability of the scale were undertaken by Oner and Le Compte . The state anxiety scale composed of 20-items that shows how a person feels at a certain moment and under certain conditions. The scale score ranges from 20 to 80, with a high scores indicating high anxiety.
Perianesthesia Comforton the 1st day after surgeryThis scale was developed by Kolcaba in 2003, and its Turkish validity and reliability were made by Üstündağ and Eti Aslan in 2010. It is used to evaluate the situation of reaching the expected increase in comfort by determining the comfort requirements. The scale consists of 24 items that question the self-concept and feelings of the individual reflecting the general thought process before and after the surgical intervention. The scale score ranges from 24 to 144, with a high scores indicating high comfort.
Patient's systolic blood pressure (mmHg)10 minutes before weaningbefore weaning 1
Diastolic blood pressures (mmHg)10 minutes before weaningbefore weaning 2
Heart rate (per minute)10 miniutes before weaning procedurebefore weaning 3
Oxygen saturation (SpO2)10 miniutes before weaning procedurebefore weaning 4
Patient's systolic blood pressure (mmHg) - after weaning 110 miniutes after weaning procedurePatient's systolic blood pressure (mmHg)
Diastolic blood pressures (mmHg) after weaning 210 miniutes after weaning procedureDiastolic blood pressures (mmHg)
Heart rate (per minute) - after weaning 310 miniutes after weaning procedureHeart rate (per minute)

Secondary

MeasureTime frameDescription
The Visual Analog Scale10 minutes after weaning procedureA 10-centimeter vertical VAS was used to assess the satisfaction assessment by patients after weaning procedure. The scale score ranges from 0 to 10, with a high scores indicating high satisfaction.

Countries

Turkey (Türkiye)

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026