Skip to content

B-amyloid as a Marker for GBM Bioimaging

B-amyloid as a Marker for GBM Bioimaging

Status
Not yet recruiting
Phases
Phase 2
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05820191
Enrollment
3
Registered
2023-04-19
Start date
2024-07-31
Completion date
2026-07-31
Last updated
2023-12-21

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Glioblastoma

Keywords

Glioblastoma, Amyvid

Brief summary

This project is aimed at improvement of glioblastoma (GBM) diagnostic strategies for discrimination of tumor progression and chemo- and radiotherapeutic treatment-related changes in brain tissue. The study will elucidate the diagnostic value of PET imaging with use of amyloid-β radioisotope tracer Amyvid (Florbetapir F18) for GBM. The results of the study will provide data for development of new approach for GBM diagnostics.

Detailed description

Glioblastoma (GBM) is one of the most malignant forms of brain cancer. Majority of GBMs relapse shortly after tumor resection, and the timely follow-up diagnosis and treatment is vital for patient's survival. However, chemo- and radiotherapeutic treatment of GBM patients cause metabolic and structural changes in brain parenchyma, manifested as metabolic and matrix remodeling modifications, and mimic tumor progression in magnetic resonance imaging (MRI) images. This creates difficulties in discrimination of real tumor progression and post-treatment modifications. No current imaging techniques, including MRI, magnetic resonance spectroscopy (MRS) or perfusion MR (MRP) can provide effective determination of tumor progression and treatment-related changes of brain tissue, that represents current unmet clinical need. The goal of the study is to identify specific biomarker for GBM, that can be used for precise imaging and diagnostics. The accumulation of amyloid-β in human GBM specimens and in mouse glioma implantation model was previously demonstrated. Intravenous administration of amyloid-β marker thioflavin T resulted in accumulation of fluorescence in brain tumors in mouse GBM model 15 minutes after administration and allowed detailed visualization of tumor structure with use of confocal microscopy. The hypothesis of the study is that Amyvid (Florbetapir F18), a radioisotope tracer, that binds amyloid aggregates and is currently used for brain PET diagnostics of Alzheimer disease, can be used as a safe and effective marker for PET diagnostics of recurrent GBM. The central study question: if Amyvid-PET provides visualization of GBM tumors and discriminate recurrent tumor and post-treatment tissue modifications in human brain, and thus presents the potential for amyloid-binding radioisotope tracers as GBM diagnostic tool. The purpose of the study is to characterize and describe the ability of Amyvid to reach GBM tumor in humans and to bind specific tumor structures as necrotic, middle and invasion areas of tumor, as well as blood vessel structures and extracellular matrix in tumor. The study is designed as human clinical trials phase 2A.

Interventions

DRUGAmyvid, Intravenous Solution

Amyvid 370MBq (10mCi) absorbed dose 7mSv of will be introduced intravenously and 30-50 minutes after the PET images will be acquired.

Sponsors

University of Puerto Rico
CollaboratorOTHER
Universidad Central del Caribe
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Masking description

Double blinding analysis of PET images will be performed. Involved Radiologists will provide their independent opinions. In addition, blinding research strategy with withholding of patient information, with three independent people involved for data collection and analysis will be used.

Intervention model description

3 patients, diagnosed with GBM, who underwent tumor resection surgery with concurrent chemo- and/or radiotherapy and developed enlarging tumor lesion, will be involved to the study. PET-CT with use of Amyvid radioisotope tracer will be performed for 3 study participants. Amyvid-PET images will be analyzed together with previously performed MRI, MRS and MRP images, to identify pattern of deposition in tumor and peri-tumoral areas of brain.Tissue specimens, separated from total tumor after planned surgical resection and prior Amyvid-PET analysis, will be analyzed to identify amyloid-β expression level, tumor phenotype and vascularization. Data will be correlated with PET images to determine whether Amyvid-positive patterns represent distinct tumor phenotype.

Eligibility

Sex/Gender
ALL
Age
21 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* GBM diagnose confirmed by MRI and histopathology * Had undergone gross total or subtotal resection of their tumor and developed enlarging and/or new enhancing lesion(s), recommended for second resection * Had or had not received radiation therapy with concomitant and adjuvant TMZ chemotherapy * Had pre-operative and follow up conventional MRI, MRS and/or Perfusion MR scans, available for analysis

Exclusion criteria

• Previous allergic reaction to radioisotope tracers

Design outcomes

Primary

MeasureTime frameDescription
Correlation of Amyvid deposition with components of high metabolic activity.Through study completion, an average of 1 yearAssociation of Amyvid deposition patterns with brain tissue components of high and low metabolic activity will be analyzed as compared to MRS images.
Measurement of Amyvid deposition in GBM tumor structuresThrough study completion, an average of 1 yearThe Amyvid patterns of deposition (brightness or darkness patterns) will be analyzed in whole brain, tumor and peri-tumor resection region with and without representation of post-treatment modifications, as compared to MRI scans.
Correlation of Amyvid deposition with components of increased vascularization.Through study completion, an average of 1 yearAssociation of Amyvid deposition patterns with areas of high and low vascularization will be analyzed as compared to MRP scans.

Secondary

MeasureTime frameDescription
Correlation of Amyvid deposition and amyloid- β expression in GBM specimens.Through study completion, an average of 1 yearTissue specimens, separated from total tumor after planned surgical resection and prior Amyvid-PET analysis, will be analyzed by western blot to quantify amyloid-β expression level and correlate with deposition of Amyvid, as identified by Amyvid-PET.
Correlation of Amyvid deposition with characteristics of tumor vasculature in GBM specimens.Through study completion, an average of 1 yearTissue specimens, separated from total tumor after planned surgical resection and prior Amyvid-PET analysis, will be analyzed with use of immunofluorescence imaging of blood vessels to characterize tumor vasculature structure (as capillary density and diameter) and correlate with deposition of Amyvid, as identified by Amyvid-PET.

Countries

Puerto Rico

Contacts

Primary ContactLilia Kucheryavykh, PhD
lilia.kucheryavykh@uccaribe.edu7877983001
Backup ContactMiguel Mayol Del Valle, MD
miguel.mayol@upr.edu787-758-2525

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026