Solid State vs. Balloon Esophageal Catheter for Estimation of Pleural Pressure

Comparison of a Solid State Versus Balloon Esophageal Catheter for Estimation of Pleural Pressure in Surgical ICU Patients

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05817968
Enrollment
16
Registered
2023-04-18
Start date
2023-10-20
Completion date
2024-03-21
Last updated
2024-05-02

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Mechanical Ventilation, Respiratory Failure

Keywords

Esophageal manometry, Respiratory monitoring, Mechanical ventilation, Pleural pressure

Brief summary

Measurements of esophageal pressure (Pes) as surrogate for pleural pressure are routinely performed in selected ICU patients to facilitate lung-protective ventilation and assess breathing effort. Pes is clinically measured via a nasogastric esophageal catheter. Current techniques involve balloon catheters but have some important disadvantages as they could deflate over time and require a very precise positioning and filling volume. A solid-state sensor does not have disadvantages associated with balloon catheters and may therefore be a useful alternative in clinical practice. This method-comparison study in adult mechanically ventilated ICU patients evaluates the accuracy of Pes measured using an esophageal catheter with a solid-state sensor as compared to a balloon catheter as reference standard.

Detailed description

Measurements of esophageal pressure (Pes) as surrogate for pleural pressure are routinely performed in selected ICU patients to facilitate lung-protective ventilation and assess breathing effort. Pes is clinically measured via a nasogastric esophageal catheter. Current techniques involve balloon catheters but have some important disadvantages as they could deflate over time and require a very precise positioning and filling volume. A solid state sensor does not have disadvantages associated with balloon catheters and may therefore be a useful alternative in clinical practice. This method-comparison study in adult mechanically ventilated ICU patients evaluates the accuracy of Pes measured using an esophageal catheter with a solid-state sensor as compared to a balloon catheter as reference standard. Subjects will receive a standard balloon esophageal catheter and a solid-state pressure catheter for simultaneous measurements of Pes. Study population will be post-surgical ICU patients. Measurements will be performed during clinical mechanical ventilation settings which include a first phase of passive controlled ventilation (patient is still sedated after surgery) as well a phase of partially-assisted ventilation where the patient's breathing effort has resumed and is assisted by the ventilator. During both phases, 10-15 minutes of tidal breathing will be recorded.

Interventions

DEVICEintelligent Esophageal Pressure Catheter (iEPC)

Placement of the iEPC nasogastric catheter with solid state sensor for esophageal manometry. Comparator: Esophageal balloon catheter (NutriVent).

Sponsors

Pulmotech B.V.
CollaboratorUNKNOWN
Erasmus Medical Center
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
OTHER
Masking
NONE

Intervention model description

Method comparison study; participants serve as their own control

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Signed informed consent * Patient requiring mechanical ventilation at the ICU following cardiothoracic or abdominal surgery * Age ≥ 18 year

Exclusion criteria

* Pregnancy * Upper airway/esophageal/mouth or face pathology (i.e. recent surgery, esophageal varices, diaphragmatic hernia) * Nasal bleeding within the last \<2 weeks * Presence of pneumothorax * Use of anticoagulants that increase the risk of catheter insertion

Design outcomes

Primary

MeasureTime frameDescription
Difference in absolute Pes-derived parameters obtained by solid state catheter vs. balloon catheter.30 minutesAbsolute Pes value (in cmH2O) at end-expiration and at peak inspiration (based on flow recordings) will be recorded.
Difference in relative Pes-derived parameters obtained by solid state catheter vs. balloon catheter.30 minutesRelative Pes value (cmH2O) will be measured as the inspiratory amplitude in Pes.

Countries

Netherlands

Outcome results

None listed