A Real-World Evidence (RWE) Long-Term Follow-Up Study to Assess Outcomes of Alcon Monofocal Intraocular Lenses

A Real-World Evidence (RWE) Long-Term Follow-Up Study to Assess Outcomes of Alcon Monofocal Intraocular Lenses

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT05799950
Enrollment
138
Registered
2023-04-05
Start date
2023-08-28
Completion date
2025-06-02
Last updated
2025-08-14

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Aphakia

Keywords

Intraocular lens, Cataract

Brief summary

The purpose of this post-market clinical follow-up (PMCF) study is to describe the long-term safety and performance of AcrySof Single-Piece and AcrySof Multi-Piece monofocal intraocular lenses (IOLs).

Detailed description

The study includes a retrospective chart review for pre-operative, operative, and post-operative data collection, and a prospective, standard-of-care visit to collect study endpoints.

Interventions

DEVICEAcrySof single-piece IOL

Acrylic single-piece intraocular lens placed in the capsular bag in the posterior chamber of the eye during cataract surgery as a replacement for the natural crystalline lens.

DEVICEAcrySof multi-piece IOL

Acrylic multi-piece intraocular lens placed in the capsular bag in the posterior chamber of the eye during cataract surgery as a replacement for the natural crystalline lens.

Sponsors

Alcon Research
Lead SponsorINDUSTRY

Study design

Observational model
COHORT
Time perspective
CROSS_SECTIONAL

Eligibility

Sex/Gender
ALL

Inclusion criteria

Key Inclusion Criteria: * Subject is implanted with one of the study IOL models between 3 and 5 years previously. * Subject follow-up is expected to be possible during the duration of the study. * Subject or legally authorized representative must be able to understand and sign the IRB/EC approved Informed Consent form. Minor subjects will complete an Assent Form. * Documented medical history and required pre-operative baseline information is available for retrospective data collection. Key

Exclusion criteria

* Subject is participating in a separate investigational drug or device study. * Pregnancy at the time of enrollment.

Design outcomes

Primary

MeasureTime frameDescription
Mean monocular best corrected distance visual acuity (BCDVA)Up to 3 to 5 years post operativeRetrospectively, the subject's medical records will be reviewed for assessments of BCDVA. Prospectively, visual acuity will be assessed for each eye individually with correction in place using letter charts placed at a distance of 6 meters (or 4 meters adjusted for infinity) from the subject. BCDVA will be reported in logarithm minimum angle of resolution (logMAR), where a logMAR value of 0 equates to 20/20 Snellen visual acuity (normal distance eyesight) and lower logMAR values indicate better visual acuity.
Rate of protocol-specified ocular adverse eventsUp to 3 to 5 years post operativeThe subject's medical records will be reviewed for medical conditions. Medical conditions that started after initial exposure to the study model IOLs will be captured as adverse events. The following adverse events are pre-specified for this outcome measure: * Cystoid macular edema (CME) * Hypopyon * Endophthalmitis * Lens dislocation * Pupillary block * Retinal detachment * Secondary surgical interventions

Secondary

MeasureTime frameDescription
Mean manifest refraction - AxisUp to 3-5 years postoperativeRetrospectively, the subject's medical records will be reviewed for manifest refraction assessments. Prospectively, the subject will be manually refracted to his/her best correction using a phoropter. The axial component will be measured in degrees.
Manifest refraction spherical equivalent (MRSE)Up to 3-5 years postoperativeRetrospectively, the subject's medical records will be reviewed for manifest refraction assessments. Prospectively, the subject will be manually refracted to his/her best correction using a phoropter. MRSE will be calculated as \[Sphere minus (cylinder divided by 2)\] and reported in diopters.
Mean monocular uncorrected distance visual acuity (UCDVA)Up to 3-5 years postoperativeVisual acuity will be assessed for each eye individually with no correction in place using letter charts placed at a distance of 6 meters (or 4 meters adjusted for infinity) from the subject. UCDVA will be measured in logarithm minimum angle of resolution (logMAR). A logMAR value of 0 equates to 20/20 Snellen visual acuity (normal distance eyesight), with lower logMAR values indicating better visual acuity.
Mean manifest refraction - SphereUp to 3-5 years postoperativeRetrospectively, the subject's medical records will be reviewed for manifest refraction assessments. Prospectively, the subject will be manually refracted to his/her best correction using a phoropter. The spherical component will be measured in diopters.
Rate of device deficienciesUp to 3-5 years postoperativeThe subject's medical records will be reviewed for device deficiencies. Examples of device deficiencies include the following: * Failure to meet product specifications (e.g., incorrect IOL power); * IOL defect; * Broken IOL optic; * Broken IOL haptic; Scratched IOL optic; * Unsealed device packaging; * Suspected product contamination; * Lack of performance. A device deficiency may or may not be associated with subject harm.
Rate of posterior capsulotomiesUp to 3-5 years postoperativePosterior capsulotomy is surgery performed on the back side of the capsular bag in the eye. A laser is used to make an opening in the cloudy capsule to allow light to pass through again for clear vision. The subject's medical records will be reviewed for the occurrence of posterior capsulotomy.
Rate of additional adverse events - OcularUp to 3-5 years postoperativeThe subject's medical records will be reviewed for medical conditions. Medical conditions that started after initial exposure to the study model IOLs will be captured as adverse events. This outcome measure will include all ocular adverse events other than the protocol-specified adverse events.
Mean manifest refraction - CylinderUp to 3-5 years postoperativeRetrospectively, the subject's medical records will be reviewed for manifest refraction assessments. Prospectively, the subject will be manually refracted to his/her best correction using a phoropter. The cylindrical component will be measured in diopters.

Countries

Puerto Rico, United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026