Skip to content

Personalised Modeling and Simulations for the Differential Diagnosis of Dynapenia: Study on Patients With Osteoarthritis

ForceLoss: Part II - Osteoarthritic Patients. Development and Validation of Methods to Generate Personalised Models for the Differential Diagnosis of the Loss of Muscle Force

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05795348
Acronym
ForceLoss II
Enrollment
20
Registered
2023-04-03
Start date
2023-03-28
Completion date
2024-05-27
Last updated
2024-05-29

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Osteoarthritis, Knee

Keywords

Dynapenia, Osteoarthritic patients, In Silico Medicine, Digital Twins, Maximal Voluntary Isometric Contraction, Musculoskeletal Modeling, Dynamometry, Electromyography, Superimposed Neuromuscular Electrical Stimulation

Brief summary

The ForceLoss study aims to develop personalised modeling and simulation procedures to enable the differential diagnosis for the loss of muscle force, namely dynapenia. The primary causes of dynapenia can be identified in a diffuse or selective sarcopenia, a lack of activation (inhibition), or suboptimal motor control. Each of these causes requires different interventions, but a reliable differential diagnosis is currently impossible. While biomedical instruments and tools can provide valuable information, it is often left to the experience of the single clinican to integrate such information into a complete diagnostic picture. An accurate diagnosis for dynapenia is important for a number of pathologies, including neurological diseases, age-related frailty, diabetes, and orthopaedic conditions. The hypothesis is that the use of mechanistic, subject-specific models (digital twins) to simulate a maximal isometric knee extension task, informed by experimental measures may be employed to conduct a robust differential diagnosis for dynapenia. In this study, on patients candidate for knee arthroplasty, the investigators will expand (i) the experimental protocol previously developed and tested on healthy volunteers with a measure of involuntary muscle contraction (superimposed neuromuscular electrical stimulation, SNMES), a hand-grip test, measures of bio-impedance and clinical questionnaires, and (ii) the modeling and simulation framework to include one additional step (to check for muscle inhibition). Medical imaging, electromyography (EMG) and dynamometry data will be collected and combined to inform a digital twin of each participant. Biomechanical computer simulations of a Maximal Voluntary Isometric Contraction (MVIC) task will then be performed. Comparing the models' estimates to in vivo dynamometry measurements and EMG data, the investigators will test one by one the three possible causes of dynapenia, and, through a process of hypothesis falsification will exclude those that do not explain the observed loss of muscle force.

Interventions

Magnetic resonance images, electromyography and dynamometry data will be used to develop and inform personalised musculoskeletal models

Sponsors

Istituto Ortopedico Rizzoli
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
65 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

* Diagnosis of Primary Arthrosis at the knee (according to the American College of Rheumatology criteria), subjects elected for tota knee arthroplasty * Body Mass Index between 18.5 and 30 kg/m2 * Health status (according to the American Society of Anesthesiology classification) equal to 1 or 2 * Suspected systemic sarcopenia due to aging or localized sarcopenia due to disuse

Exclusion criteria

* Neurological, rheumatic or tumoral diseases * Inguinal or abdominal hernia * Diabetes * Severe Hypertension (Level 3) * Severe Cardio-pulmonary insufficiency * Diagnosis of Osteonecrosis in the lower limb joints * Pathologies or physical conditions incompatible with the use of magnetic resonance imaging and electrostimulation (i.e., active and passive implanted biomedical devices, epilepsy, severe venous insufficiency in the lower limbs) * Previous interventions or traumas to the joints of the lower limb

Design outcomes

Primary

MeasureTime frameDescription
Muscle volumeat baseline (Day 0)Full lower limb MRI data will be acquired with subjects in supine position. Individual muscle volumes (in cm3) will be segmented using commercial software and stored in anonymized form.
MVIC Torqueat baseline (Day 0)Dynamometry data will be acquired while participants perform a MVIC leg extension test. The maximum torque values (Nm) measured over three repetitions will be recorded. These correspond to the values observed in correspondence of the plateaux of force, developed over a sustained contraction.
Muscle Inhibition levelat baseline (Day 0)The difference between the maximal force exerted during the MVIC test (voluntary contraction) and that achieved when the muscles are electrically stimulated (involuntary contraction) will be computed.
Co-contraction index (CCI)at baseline (Day 0)Experimental EMG data will be recorded from the major lower limb muscles involved in the knee extension, while participants perform a maximal voluntary isometric contraction on a dynamometer (i.e., MVIC test to quantify muscle strength). The co-contraction index, defined as the relative activation of agonist and antagonist muscles (for this task: quadriceps and hamstrings) in the act of kicking (MVIC test), will be computed according to Li et al (2020).

Countries

Italy

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026