Skip to content

Nicotine Pharmacokinetics of THS Single Use of a Regular or a Menthol Stick Compared to CIG

A Single-center, Randomized, Controlled, Open-label Study in Smoking Healthy Subjects to Investigate the Nicotine Pharmacokinetic Profiles Following Single Use of Tobacco Heating System (THS) With a Regular or a Menthol Stick, Compared to Smoking of a Single Combustible Cigarette (CIG)

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05789420
Enrollment
31
Registered
2023-03-29
Start date
2023-02-16
Completion date
2023-05-05
Last updated
2024-11-22

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Smoking, Tobacco

Keywords

Nicotine, Nicotine-containing products, Heated tobacco, Smoking, Tobacco, Tobacco Heating System, Pharmacokinetics

Brief summary

The purpose of this study was to describe the nicotine pharmacokinetic (PK) profile during and after single use of THS (Induction heating technology, with either a regular or menthol stick) compared to singular CIG smoking in healthy adult subjects. In addition, pharmacodynamic effects (subjective effects) were evaluated to provide further insights on product acceptance and likelihood to use the THS again. Safety was assessed throughout the study.

Detailed description

General information about the research: Study Title: Nicotine Pharmacokinetics of THS Single Use of a Regular or a Menthol Stick Compared to CIG Who carried out the research? This research was sponsored and funded by Philip Morris Products S.A. What public involvement there was in the study? Thirty-one healthy, currently smoking, adults participated in this study. Where and when the study took place? The study was conducted at a clinical trial facility managed by a contract research organization in Belfast, Northern Ireland, from February 16th to April 2nd 2023. Why was the research needed? The research was needed to understand the nicotine pharmacokinetic profile of the Tobacco Heating System (THS), with induction heating technology, in healthy smokers following single use of THS, with a regular or menthol stick, compared to cigarette single-use. What were the main questions studied? The study measured the amount and the time rate of nicotine uptake in blood plasma, and other parameters. These were the maximum nicotine plasma concentration \[Cmax\], the time to the maximum nicotine plasma concentration \[Tmax\], and further subsequent calculations describing the nicotine exposure profile. Who participated in the study? Thirty-one healthy, male or female, adults aged between 21 and 65 years participated in this study. All participants were currently smoking. The participants did not plan to quit using tobacco and/or nicotine products within the next 3 months and had smoked continuously for at least the last 3 years prior to joining the study. Each participant was given full and adequate oral and written information about the nature, purpose, possible risks, and benefits of the study. All participants received information on the risks of smoking, smoking cessation advice and a briefing on the Tobacco Heating System, for example, that its use is not risk-free. Once each participant had received all the necessary information, and if they agreed to participate, this was documented in an Informed Consent Form with the date, time, and signature of both the participant and the study doctor. Participants were informed that they were free to withdraw from the study at any time. What treatments or interventions did the participants take/receive? Thirty participants were randomly assigned to one of six possible cross-over sequences of product use (THS, with either regular or menthol stick, and cigarette) from Day 1 to Day 3 in a confinement setting. Participants could not use any other tobacco or nicotine-containing product (TNP) other than their assigned product. From Day 1 to Day 3, after at least 23 hours of abstinence from any TNP on Day 1, and at least 24 hours after former IP use on Day 2 and on Day 3 (nicotine washout), subjects smoked a CIG or used the THS either with a regular or a menthol THS stick according to their randomized product use sequence. Blood samples were collected, at several time points after product use, from Day1 to Day 3, for determination of nicotine concentration after allocated product use. Participants were also asked, from Day 1 to Day 3, to evaluate product liking, craving for cigarettes, and their intention to use the product again. These were assessed on a scale for each evaluation. The scales went from strong disliking to strong liking for product liking; from no craving to strong craving for cigarette craving; and very unlikely to very likely for intention to use again. What medical problems (adverse reactions) did the participants have? Overall, there were six mild adverse reactions reported in four participants. All the adverse reactions were mild or moderate in severity. None of these were considered related to an investigational product. There were no clinically significant findings in the physical examination, clinical laboratory, vital signs, or ECG assessments in this study. What happened during the study? A presentation of THS (without product use) was made to the participants during the Screening visit. All participants received information on the risks of smoking, smoking cessation advice, and a briefing that the use of THS is not risk-free. Eligible participants, fulfilling all criteria for participation, returned to the investigational site for admission and baseline measurements on Day -1. Subjects fasted for at least 6 hours prior to the safety laboratory assessments and started abstinence of TNP. Thirty subjects were randomized to one of 6 possible full cross-over sequences of product use (THS, with either regular or menthol THS stick, and cigarette) on Day 1 to Day 3. On Day 1 to Day 3, after at least 23 hours of abstinence from any TNP on Day 1, and at least 24 hours after THS use on Day 2 and on Day 3 (nicotine washout), subjects smoked a cigarette or used the THS either with a regular or a menthol THS stick according to randomized product use sequence. Blood samples were obtained according to the standard procedures of the investigational site. Subjects were requested to report their cigarette craving, THS liking, and intention to use the THS again. After Discharge on Day 3 or after an early termination following product exposure, the subjects entered a 3-day Safety Follow-Up period during which adverse reactions reported by the subjects were collected and followed-up, concluded by telephone contact by the investigational site on the last day of the Safety Follow-Up period. What were the results of the study? The nicotine exposure profiles and subjective effects of THS product use were assessed for THS tobacco sticks of different flavors (regular flavor; menthol flavor) and compared to those of cigarette smoking. The results of this study confirmed that nicotine exposure, from both THS Regular tobacco sticks and THS Menthol tobacco sticks, showed a lower level of nicotine uptake when using the THS Induction device compared to cigarette single use. These results are in line with historical data described for the THS device with blade heating technology. The subjective effects of THS (induction) use were comparable to those presented in previous studies that compared THS (blade) use to cigarette use, which found that cigarette use was more satisfying while THS demonstrated comparable craving reduction. Furthermore, this study found no additional safety concerns were associated with THS compared to cigarette smoking. How has this study helped patients and researchers? The participants in this study were healthy, current cigarette smokers. All participants were informed about the health risks associated with smoking and were given smoking cessation advice. Participants in this clinical study benefited from repeated and detailed general health check-ups. This clinical study may help doctors and scientists learn about electronic nicotine delivery systems. Details of any further research planned This study is part of an ongoing program of research supporting the scientific substantiation of the Tobacco Heating System. Where can I learn more about this study? More details about this study, including the study results and a copy of the study protocol, can be found on the clinicaltrials.gov website at this address: https://clinicaltrials.gov/show/NCT05789420

Interventions

OTHERP1R stick

Regular flavor tobacco stick

OTHERP1M stick

Mentholated flavor tobacco stick

OTHERCIG

Subjects' preferred brand of commercially available, regular or mentholated cigarettes

Sponsors

Philip Morris Products S.A.
Lead SponsorINDUSTRY

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
OTHER
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
21 Years to 65 Years
Healthy volunteers
Yes

Inclusion criteria

* Subject has signed the ICF and is able to understand the information provided in the ICF. * Subject has been a smoker for ≥3 years prior to the screening visit (smoking cessation attempts during this period, if any, did not last \> 6 months in total). * Subject has continuously smoked on average ≥10 commercially available regular CIG/day over the last 4 weeks. Smoking status will be verified based on a urinary cotinine test (cotinine ≥200 ng/mL). * Subject is healthy as judged by the Investigator based on available assessments from the screening period (e.g., safety laboratory, spirometry, vital signs, physical examination, ECG, and medical history). * Subject does not plan to quit smoking within the next three months.

Exclusion criteria

* As per the Investigator's judgment, the subject cannot participate in the study for any reason other than medical (e.g., psychological, social reason). * Subject is legally incompetent, or physically or mentally incapable of giving consent (e.g., in emergency situations, under guardianship, prisoners). * Subject has a clinically relevant disease which requires medication (including but not limited to gastrointestinal, renal, hepatic, neurological, hematological, endocrine, oncological, urological, immunological, pulmonary, and cardiovascular disease) or any other medical condition (including safety laboratory), which as per the judgment of the Investigator would jeopardize the safety of the subject. * Subject experienced within 30 days prior to screening/admission a body temperature \>37.5°C or an acute illness (e.g., upper respiratory-tract infection, viral infection, etc.) or the subject has a confirmed or suspected active COVID-19 infection (based on the signs and symptoms observed at the time of assessment) * As per the Investigator's judgment, the subject has medical conditions which do or will require a medical intervention (e.g., start of treatment, surgery, hospitalization) during the study participation, which may interfere with the study participation and/or study results. * Subject has relevant history of, or current asthma condition or COPD condition, and/or clinically significant findings. * Subject has donated blood or received whole blood or blood products within 3 months. * BMI \< 18.5 kg/m2 or ≥ 32.0 kg/m2. * Positive serology test for HIV 1/2, HBV, or HCV. * Subject has a positive alcohol breath test and/or has a history of alcohol disorder that could interfere with their participation in the study. * The subject has a positive urine drug test. * Subject or one of their family members is a current or former employee of the tobacco or e-cigarette industry. * Subject or one of their family members is an employee of the investigational site or of any other parties involved in the study. * Subject has participated in another clinical study within 3 months. * Subject has been previously screened or enrolled in this study. * Subject is pregnant (does not have negative pregnancy tests at Screening and at Baseline) or is breastfeeding. * For women of childbearing potential only: subject does not agree to use an acceptable method of effective contraception.

Design outcomes

Primary

MeasureTime frameDescription
Maximum Plasma Concentration [Cmax]Measured from start of product use to 24 hoursTo measure Cmax from the single use of THS with either a regular or a menthol stick or of a single cigarette.
Time to the Maximum Concentration [Tmax]Measured from start of product use to 24 hoursTo measure Tmax from the single use of THS with either a regular or a menthol stick or of a single cigarette.
Area Under the Curve of Nicotine Plasma Concentration-time Computed From T0 to T=24 Hours [AUC0-24h]Measured from start of product use to 24 hoursTo measure AUC0-24h from the single use of THS with either a regular or a menthol stick or of a single cigarette.
Area Under the Curve of Nicotine Plasma Concentration-time Computed From T0 to the Subject-specific Time of Maximum Nicotine Concentration [AUC0-t']Measured from start of product use to 24 hoursTo measure the area under the curve of nicotine plasma concentration-time computed from T0 to the subject-specific time of maximum nicotine concentration \[AUC0-t'\], from the single use of THS with either a regular or a menthol stick or from a single cigarette. (AUC0-Tmax)

Countries

United Kingdom

Participant flow

Pre-assignment details

32 subjects were screened for the study who gave informed consent and had at least one safety assessment, which were the criteria for inclusion in the Safety Population. 31 subjects were enrolled (one subject completed alternate status but was not needed for study participation due to closed enrollment). One of the enrolled subjects was discontinued due to positive alcohol breath and urine tests on Day -1. A total of 30 subjects were randomized to participate in the study.

Participants by arm

ArmCount
Safety Population
The safety population consisted of all subjects (screened \[32\], enrolled \[31\], and randomized \[30\]) who gave informed consent and had at least one safety assessment.
32
Total32

Withdrawals & dropouts

PeriodReasonFG000
Randomization to Product AssessmentsFailed alcohol breath test and urine test on day -11
Screening and Safety AssessmentsCompleted Alternate Status1

Baseline characteristics

CharacteristicSafety Population
Age, Continuous39.6 years
STANDARD_DEVIATION 10.4
Body Mass Index26.037 kg/m²
STANDARD_DEVIATION 2.8629
Race/Ethnicity, Customized
Not Hispanic or Latino
32 Participants
Race/Ethnicity, Customized
White
32 Participants
Sex: Female, Male
Female
17 Participants
Sex: Female, Male
Male
15 Participants

Adverse events

Event typeEG000
affected / at risk
deaths
Total, all-cause mortality
0 / 32
other
Total, other adverse events
0 / 32
serious
Total, serious adverse events
0 / 32

Outcome results

Primary

Area Under the Curve of Nicotine Plasma Concentration-time Computed From T0 to T=24 Hours [AUC0-24h]

To measure AUC0-24h from the single use of THS with either a regular or a menthol stick or of a single cigarette.

Time frame: Measured from start of product use to 24 hours

ArmMeasureValue (GEOMETRIC_MEAN)
P1R (THS Regular Stick)Area Under the Curve of Nicotine Plasma Concentration-time Computed From T0 to T=24 Hours [AUC0-24h]879.4 ng*min/mL
P1M (THS Menthol Stick)Area Under the Curve of Nicotine Plasma Concentration-time Computed From T0 to T=24 Hours [AUC0-24h]715.5 ng*min/mL
CIG (Cigarette)Area Under the Curve of Nicotine Plasma Concentration-time Computed From T0 to T=24 Hours [AUC0-24h]1436 ng*min/mL
Primary

Area Under the Curve of Nicotine Plasma Concentration-time Computed From T0 to the Subject-specific Time of Maximum Nicotine Concentration [AUC0-t']

To measure the area under the curve of nicotine plasma concentration-time computed from T0 to the subject-specific time of maximum nicotine concentration \[AUC0-t'\], from the single use of THS with either a regular or a menthol stick or from a single cigarette. (AUC0-Tmax)

Time frame: Measured from start of product use to 24 hours

ArmMeasureValue (GEOMETRIC_MEAN)
P1R (THS Regular Stick)Area Under the Curve of Nicotine Plasma Concentration-time Computed From T0 to the Subject-specific Time of Maximum Nicotine Concentration [AUC0-t']40.16 ng*min/mL)
P1M (THS Menthol Stick)Area Under the Curve of Nicotine Plasma Concentration-time Computed From T0 to the Subject-specific Time of Maximum Nicotine Concentration [AUC0-t']29.22 ng*min/mL)
CIG (Cigarette)Area Under the Curve of Nicotine Plasma Concentration-time Computed From T0 to the Subject-specific Time of Maximum Nicotine Concentration [AUC0-t']58.23 ng*min/mL)
Primary

Maximum Plasma Concentration [Cmax]

To measure Cmax from the single use of THS with either a regular or a menthol stick or of a single cigarette.

Time frame: Measured from start of product use to 24 hours

Population: Some participants were excluded from analysis for protocol deviations (including, but not limited to, missing measurements).

ArmMeasureValue (GEOMETRIC_MEAN)
P1R (THS Regular Stick)Maximum Plasma Concentration [Cmax]8.425 ng/mL
P1M (THS Menthol Stick)Maximum Plasma Concentration [Cmax]7.475 ng/mL
CIG (Cigarette)Maximum Plasma Concentration [Cmax]13.43 ng/mL
Primary

Time to the Maximum Concentration [Tmax]

To measure Tmax from the single use of THS with either a regular or a menthol stick or of a single cigarette.

Time frame: Measured from start of product use to 24 hours

ArmMeasureValue (MEDIAN)
P1R (THS Regular Stick)Time to the Maximum Concentration [Tmax]6.025 minutes
P1M (THS Menthol Stick)Time to the Maximum Concentration [Tmax]5.942 minutes
CIG (Cigarette)Time to the Maximum Concentration [Tmax]7.725 minutes

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026