Skip to content

Persona OsseoTi Keel Compatibility Study (Total Knee Arthroplasty)

Persona® OsseoTi® Keel Compatibility Study-A Multicenter Cohort Study A Prospective, Post-market Clinical Follow-up Study to Demonstrate Safety, Performance and Clinical Benefits of the Persona Knee System Portfolio and Its Instrumentation

Status
Active, not recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT05787821
Enrollment
760
Registered
2023-03-28
Start date
2023-06-28
Completion date
2035-06-01
Last updated
2026-07-10

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Avascular Necrosis, Flexion Deformity of Knee, Knee Pain Chronic, Osteoarthritis, Knee, Polyarthritis, Rheumatoid Arthritis, Traumatic Arthritis, Valgus Deformity, Varus Deformity

Keywords

Osteoarthritis, Total Knee Arthroplasty

Brief summary

The main objective of the study is to evaluate the safety, performance and clinical benefits of the Persona implant and its instrumentation in primary total knee arthroplasty

Detailed description

The study design is a prospective, multicenter data collection model of the 510(k) cleared Persona Total Knee System. The study will require each site to obtain institutional review board (IRB) approval prior to study enrollment. All potential study subjects will be required to participate in the Informed Consent Process. All study subjects will undergo preoperative clinical evaluations prior to their total knee arthroplasty (TKA). Investigators will collect clinical data for a required 5 years. Follow-up clinical visits include 3 months, 1, 2, 5, 7 and 10 years post-operatively. Specific assessments include: 1. Confirming the safety, performance and clinical benefits of the Persona total knee system and instrumentation in primary and revision TKA. 2. Verifying that, under normal use, the performance and clinical benefits of this device and its instrumentation conform to those intended by the manufacturer by recording patient-reported clinical outcomes measures (PROMs) and radiographic outcomes (if available).

Interventions

DEVICETotal Knee Arthroplasty

Total knee replacement.

Sponsors

Zimmer Biomet
Lead SponsorINDUSTRY

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Patient is of legal age and skeletally mature 2. Patient is willing and able to provide written Informed Consent by signing and dating the Institutional Review Board (IRB) / Ethics Committee (EC) approved Informed Consent document 3. Patient is willing and able to complete scheduled follow-up evaluations as defined in the study protocol 4. Independent of study participation, patient qualifies for either cemented or cementless primary or revision total knee arthroplasty (including salvage of previously failed surgical attempts) based upon physical exam and medical history, and meets the approved indications for use of the commercially available Persona Knee System with appropriately matched Zimmer Biomet components implanted in accordance with product labeling

Exclusion criteria

1. Patient is currently participating in any other surgical intervention or pain management study 2. Patient is pregnant or considered a member of a protected (vulnerable) population whose inclusion in the study is inappropriate (e.g. prisoner, mentally incompetent) 3. Patient has a mental or neurological condition who is unwilling or incapable of following postoperative care instructions 4. Patient has a condition which would, in the judgment of the investigator, place the patient at undue risk or interfere with the conduct of the study 5. Patient is institutionalized or is a known drug abuser, a known alcoholic or cannot understand the requirements of study participation 6. Patient is scheduled to undergo simultaneous bilateral total knee arthroplasty 7. Previous history of infection in the affected joint and/or other local/systemic infection that may affect the prosthetic joint 8. Insufficient bone stock on femoral or tibial surfaces 9. Neuropathic arthropathy 10. Osteoporosis or any loss of musculature or neuromuscular disease that compromises the affected limb 11. A stable, painless arthrodesis in a satisfactory functional position 12. Severe instability secondary to the absence of collateral ligament integrity 13. Rheumatoid Arthritis (RA) accompanied by an ulcer of the skin or a history of recurrent breakdown of the skin 14. Patient has a \> 5˚ valgus deformity with a medial collateral ligament (MCL) insufficiency, and the surgeon intends to use the personalized alignment surgical technique

Design outcomes

Primary

MeasureTime frameDescription
Oxford Knee Score (OKS)5 yearsA patient reported functional outcome score for knee arthroplasty. This score ranges from 0-48, with higher scores indicating a better outcome.

Secondary

MeasureTime frameDescription
EuroQol Five Dimension Five Level (EQ-5D-5L) Outcomes Measure5 yearsA questionnaire completed by the patient and assesses his/her general health status. This score ranges from -0.573 to 1, with higher recorded scores indicating better overall health.
Pain and Satisfaction Numeric Rating Scale (NRS)5 yearsPatients will rate their current pain intensity from 0 ("no pain") to 10 ("worst possible pain"). Along with their pain rating, subjects will be asked to rate their current satisfaction with their surgery from "Very Dissatisfied" to "Very Satisfied".

Countries

United States

Contacts

STUDY_DIRECTORHillary Overholser

Zimmer Biomet

Outcome results

None listed