Skip to content

Post-approval Follow-up Study of the IC-8 Apthera Intraocular Lens (IOL)

Post-approval Follow-up Study of the IC-8 Apthera IOL

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT05758883
Enrollment
196
Registered
2023-03-08
Start date
2023-01-12
Completion date
2024-02-16
Last updated
2024-04-02

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cataract, Presbyopia

Brief summary

The purpose of this study is to evaluate the long-term safety of the IC-8 Apthera intraocular lens (IOL).

Detailed description

A prospective, multi-center, open-label, single-group, post-approval follow-up study of IC-8 Apthera intraocular lens (IOL) subjects previously implanted with the IC-8 Apthera IOL in the Investigational Device Exemption (IDE) clinical study (G180075). All subjects will undergo one scheduled study visit, which is the 3-year post IC-8 Apthera IOL implantation visit. There is one study group: subjects enrolled in the US IDE study (G180075) and implanted with the IC-8 Apthera IOL.

Interventions

None listed

Sponsors

AcuFocus, Inc.
Lead SponsorINDUSTRY

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
22 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* Enrolled in Investigational Device Exemption (IDE) G180075 study and implanted with the IC-8 Apthera intraocular lens (IOL) * Able to comprehend and have signed a statement of informed consent * Availability, willingness, ability and sufficient cognitive awareness to comply with examination procedures and study visit(s)

Exclusion criteria

* There are no

Design outcomes

Primary

MeasureTime frameDescription
Rates of secondary surgical interventions (SSIs)3 years post IC-8 Apthera IOL implantationRates of secondary surgical interventions in the IC-8 Apthera intraocular lens (IOL) eyes will be assessed from the time the patient exited United States Investigational Device Exemption (IDE) G180075 through the Study visit
Rates of other serious adverse events3 years post IC-8 Apthera IOL implantationRates of other serious adverse events in the IC-8 Apthera intraocular lens (IOL) eyes will be assessed from the time the patient exited United States Investigational Device Exemption (IDE) G180075 through the Study visit
Rates of ocular adverse events3 years post IC-8 Apthera IOL implantationRates of ocular adverse events in the IC-8 Apthera intraocular lens (IOL) eyes will be assessed from the time the patient exited United States Investigational Device Exemption (IDE) G180075 through the Study visit
Rates of subjective visual disturbances3 years post IC-8 Apthera IOL implantationRates of subjective visual disturbances will be assessed using responses to patient Reported Outcomes (PRO) and responses to non-directed question(s)

Other

MeasureTime frameDescription
Monocular best-corrected distance visual acuity (BCDVA) in IC-8 Apthera eyes and fellow eyes3 years post IC-8 Apthera IOL implantationMonocular best-corrected distance visual acuity will be assessed at the Study visit in the IC-8 Apthera intraocular lens (IOL) eyes and in the fellow eyes
Uncorrected distance visual acuity (UCDVA), uncorrected intermediate visual acuity (UCIVA), uncorrected near visual acuity (UCNVA) in IC-8 Apthera eyes and the fellow eyes in postoperative Manifest Refraction Spherical Equivalent (MRSE) groups3 years post IC-8 Apthera IOL implantationUncorrected distance visual acuity (UCDVA), uncorrected intermediate visual acuity (UCIVA), uncorrected near visual acuity (UCNVA) in IC-8 Apthera eyes and the fellow eyes may be evaluated in postoperative Manifest Refraction Spherical Equivalent groups: -1.01 D to more myopic, -1.00 D to -0.50 D, -0.49 D to -0.25 D, -0.24 D to 0.00 D, +0.01 D to +0.25 D, +0.26 D to more hyperopic.
Rate of intraocular lens (IOL) removals due to visual/optical reasons in the IC-8 Apthera eyes and fellow eyes3 years post IC-8 Apthera IOL implantationRate of intraocular lens (IOL) removals (based on eyes with events) will be assessed at the Study visit in the IC-8 Apthera IOL eyes and in the fellow eyes
Mean monocular uncorrected distance visual acuity (UCDVA), uncorrected intermediate visual acuity (UCIVA) and uncorrected near visual acuity (UCNVA)3 years post IC-8 Apthera IOL implantationMean monocular uncorrected distance visual acuity (UCDVA), uncorrected intermediate visual acuity (UCIVA) and uncorrected near visual acuity (UCNVA) will be evaluated in the IC-8 Apthera intraocular lens (IOL) eyes and the fellow eyes
Mean distance-corrected intermediate visual acuity (DCIVA) and distance-corrected near visual acuity (DCNVA)3 years post IC-8 Apthera IOL implantationMean distance-corrected intermediate visual acuity (DCIVA) and distance-corrected near visual acuity (DCNVA) will be evaluated in the IC-8 Apthera intraocular lens (IOL) eyes and the fellow eyes

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026