Skip to content

Atraumatic Zirconia Abutment Versus Customized Composite Healing Abutment in Maxilla or Mandible.

Closure of a Guided Immediate Implant Placed in the Extraction Socket With Bone Augmentation in the Lateral Area of the Maxilla or Mandible, With a Temporary Composite Abutment vs With a Custom-made Zirconium Oxide Abutment.

Status
Active, not recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05748379
Enrollment
44
Registered
2023-02-28
Start date
2023-02-28
Completion date
2025-05-22
Last updated
2025-05-14

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Dental Anxiety, Dental Implants, Dental Implants, Single-Tooth, Female, Guided Surgery, Humans, Male, Osseointegration

Brief summary

40 patients are included in the study, 20 patients in group 1 (=closure with composite material shaper; test group) and 20 patients in group 2 (=closure with custom-made zirconia oxide abutment; control group). Randomisation envelopes will be used for randomisation. Device under study: Straumann BLX, Roxolid® , SLActive® dental implants with a diameter of 3.5, 3.75, 4, 4.5 mm are used. Allogenic bone botiss maxgraft® cortical granules are used as graft material. Inclusion criteria: 1. Males and females at least 18 years of age or older. 2. One implant per patient. 3. Prior to any study-related activity, the subject must voluntarily sign informed consent, be willing and able to attend scheduled follow-up visits, and agree to the collection and analysis of pseudonymised data. 4. Lateral individual teeth (premolars and molars). 5. Class I extraction socket (intact buccal wall) or class II (1/3 of buccal wall). 6. The gingival contour of the tooth to be extracted - without recession. 7. Adjacent anterior teeth have no periodontal loss. 8. There are no implants in the adjacent teeth. 9. Non-traumatic tooth extraction, which results in intact walls of the socket. Exclusion criteria: 1. Deep occlusion (severe, class II). 2. The patient smokes a lot (more than 10 cigarettes per day). 3. Systemic disease (osteoporosis). 4. No initial stability has been achieved after the implant insertion procedure.

Detailed description

General Notes 40 patients are included in the study, 20 patients in group 1 (=closure with composite material shaper; test group) and 20 patients in group 2 (=closure with custom-made zirconia oxide abutment; control group). Randomisation envelopes will be used for randomisation. Device under study: Straumann BLX, Roxolid® , SLActive® dental implants with a diameter of 3.5, 3.75, 4, 4.5 mm are used. Allogenic bone botiss maxgraft® cortical granules are used as graft material. Inclusion criteria: 1. Males and females at least 18 years of age or older. 2. One implant per patient. 3. Prior to any study-related activity, the subject must voluntarily sign informed consent, be willing and able to attend scheduled follow-up visits, and agree to the collection and analysis of pseudonymised data. 4. Lateral individual teeth (premolars and molars). 5. Class I extraction socket (intact buccal wall) or class II (1/3 of buccal wall). 6. The gingival contour of the tooth to be extracted - without recession. 7. Adjacent anterior teeth have no periodontal loss. 8. There are no implants in the adjacent teeth. 9. Non-traumatic tooth extraction, which results in intact walls of the socket. Exclusion criteria: 1. Deep occlusion (severe, class II). 2. The patient smokes a lot (more than 10 cigarettes per day). 3. Systemic disease (osteoporosis). 4. No initial stability has been achieved after the implant insertion procedure. 4.2. Surgical Procedures and Recovery Phase (see Annexes No. 1 and 2) Group 1. Immediate implant placement and temporary closure of tapered implants with a custom-made composite shaper after tooth extraction with bone augmentation by using allogeneic bone. 1. Non-traumatic extraction. 2. Palatal position of tapered implant for premolars and centred position for molars (more commonly - in the septum) 3-4 mm below the buccal gum line or 1-2 mm below the bony protuberance. 3. For premolars, the implant is placed palatally 2-3 mm to the buccal bone wall, for molars 2-3 mm to the buccal and lingual wall. 4. Implant insertion. 5. Jump distance sealing with allogeneic bone. 6. Temporary closure with a composite shaper. 7. Cone beam computed tomography with Carestream machine. 8. Taking a photo. 9. Scan with 3Shape TRIOS4 scanner. After 3 months, a cone beam computed tomography is performed to evaluate changes in the crestal bone, the temporary restoration is screwed off and the presence/absence of bleeding is recorded. A digital impression is taken for a zirconium oxide crown made on Ti base and to assess soft tissue changes. The change in the buccal vertical bone level will be measured as the difference between the former and the new vertical distance from implant platform to the buccal alveolar crest. While the change in the buccal horizontal bone dimension will be measured as the difference between the former and the new horizontal distance between the implant and the outer surface of the buccal plate. Both measurements will be taken using CBCT, one immediately after the surgery and the other one 3 month later. Intraoral scans with 3Shape Trios4 dental scanner will be taken to compare soft tissue stability. Measurements will be taken before, immediately after the surgery and 3 month later. By using STL files it will be possible to compare soft tissue stability. Group 2. Immediate implant placement and temporary closure of tapered implant with a custom-made zirconium oxide abutment after tooth extraction with bone augmentation by using allogeneic bone. 1. Non-traumatic extraction. 2. Palatal position of tapered implant for premolars and centred position for molars (more commonly - in the septum) 3-4 mm below the buccal gum line or 1-2 mm below the bony protuberance. 3. For premolars, the implant is placed palatally 2-3 mm to the buccal bone wall, for molars 2-3 mm to the buccal and lingual wall. 4. Implant insertion. 5. Jump distance sealing with allogeneic bone. 6. Closure with a zirconium oxide abutment. 7. Cone beam computed tomography with Carestream machine. 8. Taking a photo. 9. Scan with 3Shape TRIOS4 scanner. After 3 months, a cone beam computed tomography is performed to evaluate changes in the crestal bone, the custom-made abutment is screwed off and the presence/absence of bleeding is recorded. A digital impression is taken for a zirconium oxide crown and to assess soft tissue changes. The change in the buccal vertical bone level will be measured as the difference between the former and the new vertical distance from implant platform to the buccal alveolar crest. While the change in the buccal horizontal bone dimension will be measured as the difference between the former and the new horizontal distance between the implant and the outer surface of the buccal plate. Both measurements will be taken using CBCT, one immediately after the surgery and the other one 3 month later. Intraoral scans with 3Shape Trios4 dental scanner will be taken to compare soft tissue stability. Measurements will be taken before, immediately after the surgery and 3 month later. By using STL files it will be possible to compare soft tissue stability. Evaluation Phase T1 (Basic): After the performance of final restoration: X-ray, photograph, scan, PD, BOP, RI. T2: Follow-up after 3 months: X-ray, photograph, scan, PD, BOP, RI. T3: Follow-up after a year: X-ray, photograph, scan, PD, BOP, RI.

Interventions

PROCEDUREKompozite closure

Immediate implant placement and temporary closure of tapered implants with a custom-made composite shaper.

PROCEDUREIndividual abutment

Immediate implant placement and temporary closure of tapered implant with a custom-made zirconium oxide abutment.

Sponsors

SIA Adenta
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
DIAGNOSTIC
Masking
SINGLE (Subject)

Masking description

Each patient has their individual ID number

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Males and females at least 18 years of age or older. 2. One implant per patient. 3. Prior to any study-related activity, the subject must voluntarily sign informed consent, be willing and able to attend scheduled follow-up visits, and agree to the collection and analysis of pseudonymised data. 4. Lateral individual teeth (premolars and molars). 5. Class I extraction socket (intact buccal wall) or class II (1/3 of buccal wall). 6. The gingival contour of the tooth to be extracted - without recession. 7. Adjacent anterior teeth have no periodontal loss. 8. There are no implants in the adjacent teeth. 9. Non-traumatic tooth extraction, which results in intact walls of the socket.

Exclusion criteria

1. Deep occlusion (severe, class II). 2. The patient smokes a lot (more than 10 cigarettes per day). 3. Systemic disease (osteoporosis). 4. No initial stability has been achieved after the implant insertion procedure

Design outcomes

Primary

MeasureTime frameDescription
Stability of crestal boneBefore surgery, immediately after surgery, 3 moth, 1 year follow upTo compare crystal bone stability CBCT will be taken before surgery. , immediately after surgery, after 3 month and a follow up after 1 year. The change in the buccal vertical bone level will be measured as the difference between the former and the new vertical distance from implant platform to the buccal alveolar crest. While the change in the buccal horizontal bone dimension will be measured as the difference between the former and the new horizontal distance between the implant and the outer surface of the buccal plate. Both measurements will be taken using CBCT, one immediately after the surgery and the other one 3 month later
The changes of stability of soft tissueBefore surgery, immediately after surgery, 3 month, 1 year follow upRecession (REC) state of the gingival/mucosa border - registered by means of a periodontal probe from the incisal edge to the border of the medial, zenith and distal zones. There are taken scans with 3Shape Trios4 before surgery, immediately after, then 3 month and 1 year follow up to compare soft tissue stability
The change of position of implant using surgical guideBefore surgery and immediately after surgeryTo compare implant position accuracy using surgical guide, the following two things will be compared: DICOM after the surgery witch contains information on the implant position in the bone and the STL file witch contains information on implant position before the surgery. There are taken cone beam computer tomography before and immediately after surgery, then 3 month and 1 year follow up.

Countries

Latvia

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026