Skip to content

Predictive Value of Pre-TAVI Infrahissian Conduction Time in the Occurrence of Complete Atrioventricular Block

Predictive Value of Pre-Transcatheter Aortic Valve Implantation (TAVI) Infrahissian Conduction Time in the Occurrence of Complete Atrioventricular Block in Patients With Preoperative Right Bundle Branch Block

Status
Terminated
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05714579
Acronym
TAVHIS
Enrollment
35
Registered
2023-02-06
Start date
2023-05-30
Completion date
2024-11-20
Last updated
2025-03-25

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Aortic Stenosis, Severe

Brief summary

The purpose of the study is implantation of a Pacemaker at 30 days for occurrence of a high-grade conduction disorder per- or post-procedure (yes/no)

Detailed description

The main objective is to assess the predictive value of the pre-TAVI infrahelic conduction time interval (infraheal conduction time measured before percutaneous aortic valve implantation) on the risk of Pacemaker implantation at 30 days post-TAVI, in patients with right bundle branch block prior to surgery. The aim of the study is to identify a pre-interventional marker of the risk of rhythmological complication after the TAVI procedure (Transcatheter Aortic Valve Implantation), in order to better anticipate it. This is an interventional, prospective, longitudinal (follow-up: 12 months), multicenter (4 centers) study.

Interventions

PROCEDURETranscatheter Aortic Valve Implantation

The TAVI procedure is performed transfemorally under local anesthesia most often, or more rarely under general anesthesia via the subclavian or transaortic route. Identification is carried out under fluoroscopy in the cardiac catheterization room. The crossing of the aortic valve allows the establishment of a guide at the bottom of the left ventricle. Aortic valve predilation can be performed. The tightness of the device is checked by an aortography. Sometimes, post-dilation of the implanted bioprosthesis proves necessary, particularly in the event of under-deployment or significant para-prosthetic leakage. The duration of the intervention is approximately 1 hour.

Sponsors

Euraxi Pharma
CollaboratorINDUSTRY
GCS Ramsay Santé pour l'Enseignement et la Recherche
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
65 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patient suffering from severe aortic stenosis, eligible for a TAVI procedure (Transcatheter Aortic Valve Implantation) ; * Patient presenting with complete right bundle branch block during the pre-TAVI electrocardiogram, with QRS interval ≥ 120 ms (depolarization of the ventricles); * Patient able to understand the information related to the study, to read the information leaflet and agreeing to participate in the study. ; * Patient having signed a consent.

Exclusion criteria

* Contraindication to Transcatheter Aortic Valve Implantation ; * Patient under guardianship or curatorship, or under a regime of deprivation of liberty; * Patient participating in another clinical trial, or in a period of exclusion from another clinical trial; * Patient not benefiting from a social security scheme.

Design outcomes

Primary

MeasureTime frameDescription
Implantation of a Pacemaker at 30 days30 daysImplantation of a Pacemaker at 30 days for occurrence of a high-grade conduction disorder per- or post-procedure (yes/no)

Countries

France

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026