Sleepiz One+ Versus Capnography and Electrocardiography

Single-center Evaluation of Sleepiz One+ in Measuring Respiration Rate and Heart Rate Compared to Gold Standard

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05712226
Acronym
SPZCAP
Enrollment
36
Registered
2023-02-03
Start date
2023-02-22
Completion date
2023-04-06
Last updated
2023-05-08

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Asthma, COPD, Heart Diseases, Hypertension, Respiratory Disease, Sleep Apnea

Brief summary

EtCO2, or exhaled carbon dioxide, is a non-invasive and commonly used measure for respiratory rate and function. It can be easily monitored using a device called a capnograph, which consists of a sensor that is placed near the patient's mouth or nose and a monitor that displays the concentration of carbon dioxide in the respiratory gases in real-time. EtCO2 capnography is generally considered a reliable and accurate method for monitoring respiration and is often used as a gold standard for comparing the performance of other methods for measuring respiration. Therefore, the primary aim of this study is to provide a thorough comparison of the performance of Sleepiz One+ and EtCO2 Capnography for measuring respiration rate, in healthy adults and patients suffering from chronic conditions (e.g. hypertension, COPD, asthma, diabetes), at rest in a clinical setting. Additionally, the performance of heart rate estimation will be evaluated against ECG.

Interventions

In this study Sleepiz One+ will measure heart rate and respiration rate of a participant sitting or lying in different positions (right and left side, back, abdomen) on a bed. The recording will take around 35 minutes.

Sponsors

Sleepiz AG
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
OTHER
Masking
NONE

Masking description

Annotators of capnography data were blinded to the values provided by the investigational device

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

Patients: * Age \>=18years * Informed Consent as documented by signature * One (or more) chronic medical condition/s (e.g., diabetes, asthma, cardiovascular or respiratory diseases, etc.) Healthy volunteers * Age \>=18years * Informed Consent as documented by signature * No diagnosed chronic medical condition

Exclusion criteria

Patients * Previous enrolment into the current study, * Cardiac pacemaker or another implanted electrical device * Women who are pregnant or breastfeeding * Inability to follow the procedures of the study, e.g., due to language problems, psychological disorders, dementia, delirium etc. of the participant Healthy volunteers: * Previous enrolment into the current study, * Cardiac pacemaker or another implanted electrical device * Women who are pregnant or breastfeeding * Inability to follow the procedures of the study, e.g., due to language problems, psychological disorders, dementia, delirium etc. of the participant * Presence of diagnosed chronic medical condition

Design outcomes

Primary

MeasureTime frame
Respiration rate measurement accuracy per 60s epoch against visually scored capnography data, recorded on subjects lying down and resting on a bed.60s