Skip to content

sIPOM vs pIPOM in Incisional Hernia Patients

Medium Terms Outcome of sIPOM vs pIPOM in Patients Affected by Incisional Hernia

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT05712213
Enrollment
187
Registered
2023-02-03
Start date
2015-01-01
Completion date
2022-06-30
Last updated
2023-02-06

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Incisional Hernia

Brief summary

Nowadays, two intraperitoneal mesh approaches are commonly used in Laparoscopic Ventral Hernia Repair (LVHR): the simple intraperitoneal onlay mesh repair (sIPOM) and the intraperitoneal onlay mesh reinforcement with defect closure before placement of mesh (pIPOM). The pIPOM has been introduced to reduce adverse events in incisional hernia (IH) surgery (i.e., seroma formation, recurrences etc ) associated to laparoscopic hernia repair, and satisfactory outcomes has been reported in several studies. In details, sequelae such mesh bulging seems to be less associated to pIPOM than sIPOM, even if the latter topic is matter of intense debate. The pIPOM has been introduced in the guidelines for the laparoscopic treatment of ventral and incisional abdominal wall hernias published by the International Endohernia Society (IEHS) in 2014. Despite prospective studies on the quality of IPOM-Plus are available, the evidence level for the statements in these guidelines remains low. The aim of this prospective analysis is to compare the postoperative outcomes of patients treated for Incisional hernia (IH) with sIPOM and pIPOM after 36 months follow-up in terms of recurrence and wound events.

Interventions

PROCEDUREIntraperitoneal onlay mesh reinforcement with defect closure before placement of mesh (pIPOM)

The pneumoperitoneum (12-15 mmHg) was built up with Veres in the Palmer'point. The primary optical trocar was set in the left upper abdomen, two other trocars were set in the left middle and lower abdomen. If necessary, adhesiolysis was firstly performed. The hernia gap was deperitonealized in order to prevent a seroma formation and, if possible, all hernia sac was removed to facilitate the healing of the hernia defect after the laparoscopic suture. This also included the transection of the ligamentum teres hepatis. We reduced the intraabdominal pressure to approx. 5 mmHg and measured the hernia gap through an intraperitoneal graduated mark. The choice of mesh size was done with an overlap of more than 5 cm. The laparoscopic closure of the hernia defect was performed with non-reabsorbable detached stitches of prolene 1/0 suture at a distance of 1.5 cm from stich to stich using a Reverdin' needle. The final fixation of the mesh took place with a non-resorbable tacks.

PROCEDUREStandard intraperitoneal onlay mesh repair (sIPOM)

The pneumoperitoneum (12-15 mmHg) was built up with Veres in the Palmer'point. The primary optical trocar was set in the left upper abdomen, two other trocars were set in the left middle and lower abdomen. If necessary, adhesiolysis was firstly performed. The hernia gap was deperitonealized in order to prevent a seroma formation and, if possible, all hernia sac was removed to facilitate the healing of the hernia defect after the laparoscopic suture. This also included the transection of the ligamentum teres hepatis. We reduced the intraabdominal pressure to approx. 5 mmHg and measured the hernia gap through an intraperitoneal graduated mark. The choice of mesh size was done with an overlap of more than 5 cm. In sIPOM, the defect was not closed. The final fixation of the mesh took place with a non-resorbable tacks.

Sponsors

University of Campania Luigi Vanvitelli
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 65 Years
Healthy volunteers
No

Inclusion criteria

* Incisional Hernia whit length \>3 and \<12 in width or length (Medium size according to European Hernia Society classification incisional hernias * Body mass index (BMI) \< 35 kg/m2 * Elective surgery setting * Clean wound field according to the Centre for Disease Control and Prevention (CDC) wound classification (Grade I)

Exclusion criteria

* Incisional hernia \<3 or \>12 cm * Abdominal aortic aneurysm disorders * Pregnancy or lactation * Psychiatric illness * Multifocal hernia defect * Life expectancy\<2 years * Inflammatory bowel disease * emergency setting

Design outcomes

Primary

MeasureTime frameDescription
Evaluation of the Hernia Recurrence (HR) postoperatively in pIPOM Group and sIPOM Group36 monthsHernia Recurrence (HR) in pIPOM and sIPOM, was clinically and ultrasonographically evaluated at outpatient visit. In details, HR was clinically defined as any visible or palpable ''blowout'' in the abdominal wall. US evaluation was carried out by a radiologist with 15 years of gastrointestinal US experience. A RS85 (Samsung Madison Co Ltd., Seoul, Korea) ultrasound with a convex transducer (CA1-7A) was employed. The ultrasonic criteria of HR were a visible gap within the abdominal wall and/or ''tissue moving through the abdominal wall by Valsalva manoeuvre'' and/or a detectable ''blowout''. Size and location of all ultrasound detected HR were registered, as well as any other patient's complaint. In doubtful cases of HR, computerized tomography (CT) was performed. HR was diagnosed and recorded if clinical criteria and/or ultrasound criteria were fulfilled.
Evaluation of the Mesh Bulging (MB) rate postoperatively in pIPOM Groups and sIPOM Group36 monthsMesh Bulging (MB) as any clinically evident protrusion through the hernial defect and opens into the hernial sac causing swelling. It was as well clinically and ultrasonographically evaluated at outpatient visit. US evaluation was carried out by a radiologist with 15 years of gastrointestinal US experience. A RS85 (Samsung Madison Co Ltd., Seoul, Korea) ultrasound with a convex transducer (CA1-7A) was employed. In doubtful cases of MB, computerized tomography (CT) was performed. MB was diagnosed and recorded if clinical criteria and/or ultrasound criteria were fulfilled.

Secondary

MeasureTime frameDescription
Evaluation of the incidence of wound events in pIPOM Group and sIPOM Group30 daysThe classification of wound events was assigned according to the likelihood and degree of wound contamination at the time of the operation, as stated in the Centre for Disease Control and Prevention (CDC) wound classification (superficial, deep or organ space). Surgical site events were reported according to the Ventral Hernia Working Group definitions. Actions for wound events were categorized as follows: antibiotics only, bedside wound interventions, percutaneous maneuvers or surgical debridement.
The evaluation of Quality of Life - Gastrointestinal quality of life index (GIQLI) questionnaire in pIPOM Group and sIPOM Group36 monthsThe Gastrointestinal Quality of Life Index (GIQLI) is a validated, 36-item, self-administered questionnaire that addresses 5 domains: upper gastrointestinal symptoms (12 items), lower gastrointestinal symptoms (7 items), physical status (7 items), psychological status (5 items), and social status (5 items). Each item is quoted from 0 to 4; scores range from 0 to 144, with higher scores indicating better function. Correct or incorrect allocation was then evaluated.

Outcome results

None listed