Skip to content

CTI Ablation Guided by Omnipolar Wave Speed and Voltage Maps to Diminish RF and Fluoroscopy Times

CTI Ablation Guided by Omnipolar Wave Speed and Voltage Maps to Diminish RF and Fluoroscopy Times

Status
Recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05709795
Enrollment
200
Registered
2023-02-02
Start date
2023-03-01
Completion date
2025-01-31
Last updated
2024-04-03

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Flutter

Brief summary

Prospective randomized study involving patients with typical flutter (TF) undergoing cavo-tricuspid isthmus (CTI) radiofrequency ablation. The aim is to compare the results of 3 different new ablation strategies using Omnipolar technology to classic linear ablation. The investigators´ aim is to compare the effectiveness, safety and procedure times of CTI ablation with 3 different strategies using the Ensite X navigator in magnetic mode with Omnipolar technology and HDGrid catheter to optimize radiofrequency (RF) and fluoroscopy times with classical linear ablation. The number of patients needed to prove the investigators´ hypothesis is of at least 50 per group (total of 200 prospective patients

Detailed description

Background Ablation procedures for CTI-dependent TF have classically been guided by fluoroscopy and intracavitary electrograms from diagnostic catheters placed in the right atrium (RA), the coronary sinus (CS) and the CTI (ablation catheter). Over the last few years, the use of navigators has increased considerably not only for complex procedures, but also for simple procedures, with the aim of reducing and even completely eliminating irradiation to both the patient and the operator (1). The investigators´ group is looking to characterize the high voltage and the low velocity regions in the CTI to minimize the procedure times. This has been addressed in a recent observational study with very good results. Rationale There is increasing evidence of the benefits using 3D-systems not only to diminish fluoroscopy, but also to guide ablation targeting high voltage areas in the CTI (2-5). It is well known also the existence of low speed areas in the CTI, facilitating the presence of reentrant circuits (6,7). Currently, the investigators´ center performs all CTI ablation procedures using a 3D-navigator system, mostly with zero or minimal fluoroscopy. The investigators´ group has carried out a preliminary study with 13 patients to assess the effectiveness of CTI ablation with the use of the Ensite X navigator in magnetic mode with Omnipolar technology and HDGrid catheter. In this observational study the investigators were able to characterize the high voltage and the low velocity regions in the CTI to minimize the RF lesions and procedure times. Acute bidirectional block was achieved in 100% of patients with an average fluoroscopy time of 1 ± 2 min (77% patients with zero fluoroscopy) and an average RF time of 5,7 ± 3,2 min (38% below 3 min). This results were significantly lower than results obtained with classical linear ablation: median fluoroscopy time 19.3 min, IQR 12.9 to 36.4 min, median fluoroscopy dose 3520.7 cGycm(2), IQR 1700.0 to 6709.0 cGycm(2). From the investigators´ point of view this observational study, together with previous evidence justify a randomized study in order to confirm our hypothesis: Hypothesis Omnipolar technology is able to guide the ablation procedure minimizing both the RF time and the fluoroscopy time (compared to linear ablation) by targeting only the critical regions on the CTI. Therefore Omnipolar technology will diminish RF time and fluoroscopy time/exposition compared to classical CTI ablation, and by means of this the investigators expect an inferior complications rate. Importantly acute success rate and 6 months follow-up recurrences rate will remain similar. OBJECTIVES * Primary objectives: to optimize procedure times of CTI ablation with 3 different strategies based in voltage and/or conduction velocity maps using the Ensite X navigator in magnetic mode with Omnipolar technology and HDGrid catheter compared to classical linear ablation. o Specific objectives: Fluoroscopy time, radiofrequency time, radiation dose, percentage of zero-fluoroscopy procedures, acute efficacy, complications rate. * Secondary objectives: to increase the effectiveness of CTI ablation with 3 different strategies based in voltage and/or conduction velocity maps using the Ensite X navigator in magnetic mode with Omnipolar technology and HDGrid catheter compared to classical linear ablation. * Specific objectives: Recurrences rate at 6 months.

Interventions

PROCEDUREConfluent areas

Use of omnipolar technology to guide CTI ablation in sites with both low wave speed and high voltage. If not successful then ablation of low wave speed sites. If not successful then ablation of high voltage sites. If not successful then CTI line (gold standard)

PROCEDUREWave Speed

Use of omnipolar technology to guide CTI ablation in sites with low wave speed. If not successful then ablation of sites with both low wave speed and high voltage. If not successful then ablation of high voltage sites. If not successful then CTI line (gold standard)

PROCEDUREVoltage

Use of omnipolar technology to guide CTI ablation in sites with high voltage. If not successful then ablation of sites with both low wave speed and high voltage. If not successful then ablation of low wave speed sites. If not successful then CTI line (gold standard)

PROCEDURECTI line

Do not use omnipolar information. CTI line performance

Sponsors

Abbott
CollaboratorINDUSTRY
Parc de Salut Mar
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
SINGLE (Subject)

Masking description

Patient won´t know what strategy has been followed to achieve CTI block

Intervention model description

Prospective randomized multicentric

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patients submitted to CTI ablation for TF * Age above 18 years

Exclusion criteria

• Life expectancy of \<1 year

Design outcomes

Primary

MeasureTime frameDescription
Radiation dose24 hoursAmount of Radiation dose needed to achieve complete CTI block (acute success)
Radiofrequency time24 hoursAmount of Radiofrequency needed to achieve complete CTI block (acute success)
Fluoroscopy time24 hoursAmount of Fluroscopy time needed to achieve complete CTI block (acute success)
Complications2 monthsPercentage of procedural complications
Zero Fluoroscopy24 hoursPercentage of patients performed without the use of fluoroscopy
Acute efficay24 hoursPercentage of acute succeess (complete block of the CTI)

Secondary

MeasureTime frameDescription
Flutter recurrences6 monthsPercentage of recurrences of typical flutter at 6 months follow up

Countries

Spain

Contacts

Primary ContactErmengol Valles, PhD
evalles@psmar.cat0034932483118

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026