SOUND Pivotal Trial - (Sonomotion stOne comminUtion resoNance ultrasounD)

Pivotal Study of the SonoMotion Break Wave™ (Trade Mark) System for the Comminution of Urinary Tract Stones

Status
Completed
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05701098
Acronym
SOUND
Enrollment
64
Registered
2023-01-27
Start date
2023-10-09
Completion date
2025-07-31
Last updated
2026-05-04

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Kidney Calculi, Kidney Stone, Nephrolith, Nephrolithiasis, Renal Calculi, Urinary Calculi, Urolithiasis

Keywords

Kidney Stone, Urolithiasis, Nephrolithiasis, Renal Calculi, Kidney Calculi, Nephrolith, Urinary Calculi, Ultrasound therapy, Non-invasive, Extracorporeal

Brief summary

The goal of this clinical trial is to test the Break Wave™ system in patients with upper urinary tract stones. The main question it aims to answer is whether the device is safe and effective in fragmenting (breaking) stones. Participants will a) undergo the Break Wave™ procedure, b) have a telehealth visit at 2 weeks, and c) return for an imaging study at approximately 10 weeks post-procedure.

Detailed description

This is a prospective, open-label, multi-center, single-arm (non-randomized) study to demonstrate the safety and effectiveness of breaking stones in the upper urinary tract using the SonoMotion Break Wave™ technology. Up to 116 patients will be screened to participate. Depending on the institution, the procedure may be performed in an outpatient hospital surgical environment, or in a non-surgical environment such as a clinic or office procedure room. Subjects will have a target stone diagnosed to be \>4millimeter (mm) to 10 mm in size. Safety will be measured by the adverse event occurrence, unplanned emergency department or clinic visits, and the need for further intervention. Effectiveness will be determined by the size of fragments identified at the 10 week follow-up imaging.

Interventions

The Break Wave device will be used to exert a low amplitude burst of ultrasound waves focused at the kidney stone. The primary components of the device include an ultrasound imaging system and a therapy probe driven by a high voltage generator. The probe will be placed on the patient's skin, the stone located via diagnostic ultrasound and up to 30 minutes of therapy will be delivered to the stone. The therapy probe accommodates coaxial alignment of an ultrasound imaging probe for treatment guidance.

Sponsors

SonoMotion
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Subjects presenting with at least one stone apparent on radiographic imaging. 2. Target stone must be within the upper urinary tract. 3. Target stone is indicated for shock wave lithotripsy (SWL) treatment per American Urological Association (AUA) 2016 guidelines. 4. Target stone size is \> 4 mm and ≤ 10 mm. 5. Subject is willing and able to provide informed consent and comply with the study protocol required follow up visits. 6. Target stone can be individually visualized from other stones.

Exclusion criteria

1. Subject has an acute untreated urinary tract infection or urosepsis. 2. Subject has an uncorrected bleeding disorder or coagulation abnormality. 3. Subject is confirmed to be or suspected to be pregnant. 4. Subject has a urinary tract obstruction distal to the stone. 5. Subject is receiving anticoagulants and is unable or not willing to cease the medication for the Break Wave procedure 6. Subject has stones that are not echogenically visible with ultrasound. 7. Subject belongs to a vulnerable group (prisoner, etc.). 8. Patients unwilling to comply with the follow-up protocol, including post-procedure radiographic imaging. 9. Subject is under 18 years of age. 10. Subject's anatomy limits ability to focus on or deliver Break Wave to the target stone (e.g. viable acoustic window). 11. Subject has a calcified abdominal aortic aneurysm or calcified renal artery aneurysms. 12. Subject has a solitary kidney. 13. Subject has a comorbidity risk(s) which, at the discretion of the physician, would make the subject a poor candidate for the Break Wave procedure, such as anatomical anomalies that may not be conducive to adequate stone fragment passage. 14. Subject is unable to read or comprehend the consent form.

Design outcomes

Primary

MeasureTime frameDescription
Primary Effectiveness Endpoint10 +/- 2 weeks post final Break Wave procedureProportion of subjects with a radiographic assessment of the target stone demonstrating either (i) stone free status (zero fragments) or (ii) the presence of only stone fragments small enough to pass spontaneously (≤ 4 mm).
Primary Safety EndpointDuring procedure and through 90 days post-procedureOccurrence of device and procedure related clinically significant or symptomatic hematoma (perirenal/intrarenal), urinary tract sepsis, or serious cardiac arrhythmia

Secondary

MeasureTime frameDescription
Secondary safety endpointDuring procedure and through 90 days post-procedureOccurrence of all device and procedure related adverse events (AEs), including serious adverse events (SAEs), and Unanticipated Adverse Device Effects (UADEs)

Countries

Canada, United States

Outcome results

None listed