Skip to content

Pulse Oximetry Accuracy by Skin Color

Pulse Oximetry Accuracy by Skin Color

Status
Withdrawn
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT05692453
Enrollment
0
Registered
2023-01-20
Start date
2026-07-01
Completion date
2027-12-01
Last updated
2026-09-14

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Surgery

Brief summary

This is a prospective, non-randomized, non-blinded comparative study to evaluate the accuracy of pulse oximetry compared to co-oximetry in dark-skinned (Black) compared to lighter-skinned (White) children undergoing anesthesia, using standard FDA performance statistics as measured by mean bias and accuracy root mean squared to evaluate device performance.

Detailed description

This is a prospective, non-randomized, non-blinded comparative study. There will be no changes to the anesthetic or surgical plan to accommodate this study. Patients undergoing anesthesia will be induced per their anesthetic team. Following endotracheal intubation, the patient will be placed on air (FiO2 21%) at 4 liters per minute fresh gas flow. After a minimum of 3 minutes has elapsed, the anesthesia team will obtain an arterial blood sample of approximately 1 mL. This can be obtained from an arterial line if one is planned for the procedure or already in place by accessing the line per standard procedure. If an arterial line is not placed, the arterial sample will be obtained by percutaneous arterial puncture using ultrasound guidance and a 25-gauge blood gas syringe. The patient's SpO2 will be noted using a pulse oximetry probe placed on the right index finger when the arterial sample is drawn, along with the date/time of sample acquisition. Once the sample is drawn, the patient's anesthetic and surgery will proceed as per his anesthesia team. The arterial sample will be immediately delivered to the Nationwide Children's Hospital laboratory for simultaneous ABG and ABG-CoOx analysis to obtain SaO2S and SaO2C, respectively.

Interventions

DIAGNOSTIC_TESTArterial blood gas with co-oximetry

1 mL blood sample for ABG-CoOx analysis to obtain co-oximetry measured arterial oxygen saturation (SaO2C) and standard ABG derived arterial oxygen saturation (SaO2S).

Sponsors

Brittany Willer
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
2 Years to 9 Years
Healthy volunteers
No

Inclusion criteria

* Children aged 2-9 years undergoing general anesthesia with or without arterial line placement.

Exclusion criteria

* Patients with cyanotic congenital heart disease. * Patients with bleeding disorders. * Patients taking blood thinners.

Design outcomes

Primary

MeasureTime frameDescription
Accuracy of Pulse OximetryBaselineAccuracy of pulse oximetry readings (SpO2) as compared with arterial oxygen saturations measured by arterial blood gas with co-oximetry (ABG-CoOx).

Countries

United States

Contacts

PRINCIPAL_INVESTIGATORBrittany Willer, MD

Nationwide Children's Hospital

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Sep 15, 2026