Skip to content

Bougies as Aid for Endotracheal Intubation Via Video Laryngoscopy During Continuous Chest Compressions

Bougies as Aid for Endotracheal Intubation Via Video Laryngoscopy During Continuous Chest Compressions by Anesthesia Residents: a Randomized Crossover Simulation Trial

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05689125
Enrollment
65
Registered
2023-01-18
Start date
2023-02-09
Completion date
2023-02-20
Last updated
2023-06-13

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cardiopulmonary Resuscitation, Endotracheal Intubation, Simulation

Brief summary

The goal of this clinical trials is to analyze the effects of using bougies as adjuncts on the performance of endotracheal intubation via video laryngoscopy during cardiopulmonary resuscitation in anesthesia residents. The main question it aims to answer is whether bougie use has a significant effect on first-attempt failure of endotracheal intubation via video laryngoscopy during continuous chest compressions. Participants will perform endotracheal intubation via video laryngoscopy by four methods in a randomized order in a simulated cardiopulmonary resuscitation scenario on a manikin. The four methods are endotracheal intubations assisted by a railroaded bougie, assisted by a preloaded bougie, assisted by a stylet, and with no assistance. Researchers will compare the first-attempt failure rate of the four methods to see if a railroaded bougie method has a significant different first-attempt failure from that of the other three methods.

Interventions

DEVICERailroaded bougie

Residents expose the glottis by a video laryngoscope and place the tip of bougie through the vocal cords. Then, an assistant loads an endotracheal tube on the free end of the bougie. Residents advance the endotracheal tube over the bougie and withdraw the bougie.

DEVICEPreloaded bougie

Residents expose the glottis by a video laryngoscope and perform the endotracheal intubation using a bougie with a preloaded endotracheal tube while an assistant secures the free end of the bougie. Residents withdraw the bougie when the endotracheal tube reaches an appropriate depth.

DEVICEStylet

Residents expose the glottis by a video laryngoscope and perform the endotracheal intubation with the assistance of a stylet. An assistant withdraws the stylet when the tip of the endotracheal tube passes through the vocal cords. Then residents place the endotracheal tube to an appropriate depth.

Sponsors

Peking Union Medical College Hospital
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
TREATMENT
Masking
NONE

Intervention model description

Participants will perform endotracheal intubation by four methods in a randomized order. The four methods are endotracheal intubations assisted by a railroaded bougie, assisted by a preloaded bougie, assisted by a stylet, and with no assistance.

Eligibility

Sex/Gender
ALL
Healthy volunteers
No

Inclusion criteria

* Residents who are enrolled in the three-year standardized residency training program in the Department of Anesthesiology, Peking Union Medical College Hospital in February, 2023.

Exclusion criteria

* Residents who refuse to participate and residents who fail the pre-test.

Design outcomes

Primary

MeasureTime frameDescription
Failure on the first attemptAt the completion of the intubationAn attempt is terminated and defined as a failure when a resident tries for one minute but is still unable to start ventilation, or when a resident feels unable to succeed and decides to give up, or when a resident withdraws a laryngoscope blade, a bougie, or a tube out of the month after the initial insertion. This outcome will be measured based on videos of endotracheal intubation procedures recorded by a camera placed on the right side of the manikin.

Secondary

MeasureTime frameDescription
Failure on two attemptsAt the completion of the intubationIf the first attempt of a method fails, the resident will be given a second opportunity of the same method. This outcome will be measured based on videos of endotracheal intubation procedures recorded by a camera placed on the right side of the manikin.
Duration of the first attemptAt the completion of the intubationThe time elapsed between the insertion of a laryngoscope blade into the month and either the start of ventilation in a successful attempt or the termination of a failed attempt. This outcome will be measured based on videos of endotracheal intubation procedures recorded by a camera placed on the right side of the manikin.
Overall intubation durationAt the completion of the intubationDuration of the first attempt if it succeeds or the sum of the duration of both attempts if the first attempt fails. This outcome will be measured based on videos of endotracheal intubation procedures recorded by a camera placed on the right side of the manikin.
Self-reported intubation difficultyAt the completion of the intubation0-10 ranking scale with 0 representing the easiest and 10 the most difficult rated by the residents.

Countries

China

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 7, 2026