Evaluation of Tracheal Pressure During CPAP

Evaluation of Tracheal Pressure During Continuous Positive Airway Pressure Ventilation - a Prospective, Clinical Trial

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05679635
Enrollment
20
Registered
2023-01-11
Start date
2022-11-24
Completion date
2024-05-14
Last updated
2024-05-28

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Continuous Positive Airway Pressure, CPAP Ventilation

Keywords

tracheal pressure, airway pressure

Brief summary

This trial evaluates tracheal pressure values in intubated intensive care unit patients during continuous positive airway pressure without any ventilatory support, automatic tube compensation and assisted spontaneous breathing.

Detailed description

Aim of this trial is to investigate if there are any significant differences between airway and tracheal pressure values during continuous positive airway pressure (CPAP) ventilation. For this purpose, a tracheal pressure measurement catheter is inserted into the tracheal tube and the obtained values are compared with the corresponding airway pressure measured on the ventilator. To further evaluate the impact of mild respiratory support automatic tube compensation and assisted spontaneous breathing with 4 cmH2O will be applied and measured pressure values compared as well. We hypothesize that tracheal pressure will be significantly lower than airway pressure values during inspiration, which represents the primary outcome measure. Secondary outcome parameters include comparison of expiratory and mean pressure values of airway and tracheal pressure. Additionally, effects of mild respiratory support will be evaluated as well. Measurement of inspiratory tracheal pressure might allow to calculate the pressure drop between the airway pressure at the Y-piece of the ventilator and the pressure at the trachea. Currently it is not known, if this pressure drop is significant during CPAP, which represents the rationale to perform this pilot study. In a second step it would be possible to determine if the recorded pressure drop can be used as a surrogate parameter for the respiratory drive in terms of a risk assessment for the development of patient self-inflected lung injury.

Interventions

DEVICEEvone

The conventional tube adapter (CTA) from the Evone ventilator (Ventinova Medical B.V., Eindhoven, The Netherlands), equipped with an tracheal pressure measurement catheter will be connected to the tracheal tube of intubated intensive care unit patients. Subsequently tracheal pressure values will be displayed and recorded from the ventilator.

DEVICEEvita Infinity V500

Displayed airway pressure values will be directly recorded from the Evita Infinity V500 ventilator (Dräger Medical, Lübeck, Germany)

Sponsors

Medical University Innsbruck
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
BASIC_SCIENCE
Masking
NONE

Intervention model description

prospective, open, clinical trial

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Male and female subjects ≥ 18 years * Intubated patient during CPAP without pressure support * Informed consent

Exclusion criteria

* Female subjects known to be pregnant * Known participation in another clinical trial * Critical pulmonary state (paO2/FiO2 ratio \<100)

Design outcomes

Primary

MeasureTime frameDescription
inspiratory tracheal pressure10 minutes after insertion of the tracheal pressure measurement catheterThe lowest tracheal pressure value, representing the highest inspiratory effort, will be recorded from the ventilator

Secondary

MeasureTime frameDescription
mean tracheal pressure10 minutes after insertion of the tracheal pressure measurement catheterThe mean tracheal pressure value will be calculated
peak tracheal pressure10 minutes after insertion of the tracheal pressure measurement catheterThe highest tracheal pressure value will be recorded
inspiratory tracheal pressure during automatic tube compensation (ATC)10 minutes after adding ATCEffect of a mild respiratory support in terms of automatic tube compensation (ATC) on inspiratory tracheal pressure will be evaluated.
inspiratory tracheal pressure during assisted spontaneous breathing (ASB)10 minutes after adding ASBEffect of a mild respiratory support in terms of assisted spontaneous breathing (ASB) with 4 cmH2O on inspiratory tracheal pressure will be evaluated.

Countries

Austria

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026