Skip to content

Feasibility Study of the DragonFly-T System for Severe Tricuspid Regurgitation

Feasibility Study of the DragonFly-T Transcatheter Tricuspid Valve Repair System for the Treatment of Tricuspid Regurgitation

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05671640
Enrollment
10
Registered
2023-01-04
Start date
2022-10-27
Completion date
2024-01-10
Last updated
2023-01-04

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Tricuspid Regurgitation

Keywords

Tricuspid Regurgitation

Brief summary

This study is a prospective design. Patients are severe tricuspid regurgitation (TR) (≥ 3+) who remained clinically symptomatic after guideline-directed medical treatment. After signing an informed consent form, subjects are enrolled and treated with the DragonFly-T Transcatheter Tricuspid Valve Repair System. All subjects receive clinical follow-up immediately after the procedure, before discharge, 30 days after the procedure, 6 months after the procedure, 12 months, and 2, 3, 4, and 5 years after the procedure. The incidence of MAEs (Major Adverse Events) at 30 days is used as the safety endpoint. The MAEs include stroke, cardiovascular death, new renal failure, endocarditis requiring surgery, and non-elective cardiovascular interventions due to device-related adverse events. The efficacy endpoints include acute procedural success, acute device success, the incidence of all-cause mortality and/or heart failure rehospitalization at 12 months after the procedure, the percentage of patients with tricuspid regurgitation of 2+ or less, the percentage of patients with tricuspid regurgitation reduced by at least one grade, the improvement in 6 minutes walk test, New York Heart Association (NYHA) class, quality of life change as assessed by the Kansas City Cardiomyopathy Questionnaire (KCCQ) score and change in edema scale grading.

Interventions

To conduct edge-to-edge repair with DragonFly-T System under the guidance of transesophageal echocardiography.

Sponsors

Hangzhou Valgen Medtech Co., Ltd
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Age ≥ 18 years 2. In the judgment of the local cardiac team, the patient has been adequately treated according to applicable standards (including medical management), including: 1. Optimal pharmacological therapy for TR (e.g. diuretics); 2. Drug and/or interventional treatment of mitral regurgitation, atrial fibrillation, coronary artery disease, and heart failure; 3. The Eligibility Committee confirms that the patient has received adequate medical treatment. 3. Despite the drug optimization treatment according to the above method, patients still have symptoms of TR (TR grade≥3+). 4. New York Heart Association (NYHA) Cardiac function Class II-IVa. 5. The patient is suitable for transcatheter tricuspid valve repair, suitable for the use of the study device, and the femoral vein access is feasible and can accommodate a 24F catheter. 6. Patient must provide written informed consent before any steps related to the study.

Exclusion criteria

1. Tricuspid valve leaflet anatomy, which may preclude clip implantation or proper clip positioning on the leaflets, including but not limited to the following: 1. Evidence of calcification in the grasping area; 2. Presence of a severe coaptation defect of the tricuspid leaflets; 3. Severe leaflet defect(s) and cleft preventing proper device placement determined by ECL; 4. Epstein anomaly. 2. Previous tricuspid valve surgery or transcatheter therapy. 3. Echocardiography suggested intracardiac thrombus, tumor, or mass. 4. Transthoracic Echocardiogram and Transesophageal Echocardiography are unable to evaluate tricuspid valve anatomy. 5. Refractory heart failure requiring intervention (e.g., left ventricular assist device, heart transplantation) (ACC/AHA Stage D heart failure). 6. Severe and uncontrolled hypertension: systolic blood pressure ≥ 180mmHg and/or diastolic blood pressure ≥ 110mmHg. 7. Active endocarditis, active rheumatic heart disease, or rheumatic heart valvular disease leading to tricuspid valve leaf lesions (poor valve leaf compliance, perforation, etc.). 8. Had myocardial infarction or unstable angina within 4 weeks; Untreated severe coronary artery stenosis requiring revascularization. 9. Percutaneous coronary intervention was performed within 30 days before surgery, except for coronary angiography. 10. Hemodynamic instability, defined as systolic blood pressure \< 90mmHg, with or without cardiogenic shock, or requiring intra-aortic balloon counterpulsation or other hemodynamic support devices. 11. Bleeding diseases or coagulation disorders, or antithrombotic drug therapy contraindications. 12. Acute peptic ulcer or gastrointestinal bleeding within 3 months before surgery. 13. Severe cirrhosis (Child's grade C). 14. Allergy to the device material. 15. Life expectancy of fewer than 12 months. 16. Women who are pregnant, breastfeeding, or planning to become pregnant. 17. Participated in any drug and/or medical device clinical trials within 1 month prior to the trial. 18. The researchers do not consider it appropriate to be enrolled in the study.

Design outcomes

Primary

MeasureTime frameDescription
Incidence of major adverse events (MAEs)30 daysMAEs include stroke, cardiovascular death, new renal failure, endocarditis requiring surgery, and non-elective cardiovascular interventions due to device-related adverse events

Secondary

MeasureTime frameDescription
Acute device successImmediately after procedureOne or more DragonFly-T devices are successfully delivered and released, edge-to-edge leaflet repair confirmed by echocardiogram, and successfully withdrawal of the delivery catheter
Incidence of all-cause mortality and/or heart failure rehospitalization12 monthsIncidence of all-cause mortality and/or heart failure rehospitalization
Tricuspid regurgitation severity30 days, 6 months, 12 monthsPercentage of patients with tricuspid regurgitation of 2+ or less
Tricuspid regurgitation severity change30 days, 6 months, 12 monthsPercentage of patients with tricuspid regurgitation reduced by at least one grade
Acute procedural successImmediately after procedureSuccessful in DragonFly-T implantation, and residual TR of 2+ or less at discharge. An echocardiography echocardiogram at 30 days can be accepted if the discharge image was not available or hard to interpret. A death before discharge or a re-operation of tricuspid valve prior to 30 days is defined as acute procedure failure
Change in NYHA class30 days, 6 months, 12 monthsImprovement in New York Heart Association (NYHA) Function Class
Quality of life improvement30 days, 6 months, 12 monthsImprovement in quality of life (QoL) , as measured by the Kansas City Cardiomyopathy Questionnaire
Change in edema grading30 days, 6 months, 12 monthsImprovement in grading of edema,1-4 grade scale,higher scores mean worse outcome
Change in 6 Minutes Walk Test30 days, 6 months, 12 monthsImprovement in 6 Minute Walk Test

Countries

China

Contacts

Primary ContactKangmu Ma
makangmu@valgenmed.com+8613341773508
Backup ContactShuangjie Li
shuangjie.li@valgenmed.com+8617756106609

Outcome results

None listed