Skip to content

Comparative Assessment of Failure Rate of Fixed Lingual Retainer Between Two Types of Light Cured Resin Composite

Comparative Assessment of Failure Rate of Fixed Lingual Retainer in Finished Orthodontic Cases Between Two Types of Light Cured Resin Composite. A Randomized Clinical Trial

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05660668
Enrollment
90
Registered
2022-12-21
Start date
2022-11-01
Completion date
2023-08-01
Last updated
2023-01-04

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Orthodontic Retainer

Brief summary

The study will be performed on human subjects with finished orthodontic treatment to see the failure rate(detachment) of fixed lingual retainer between two types of light cure resin composite

Detailed description

The study consists of two groups, the intervention involve performing bonding of fixed lingual retainer with light cured composite Transbond LR which is manufactured specific for the fixed lingual retainer while the control group involve bonding of fixed lingual retainer by light cured composite Transbond XT with follow up every month for 6 month to see the failure rate(detachment) between the two types of composite

Interventions

OTHERTransbond LR

cleaning the lingual surface using oil free pumice then apply acid etch 35% phosphoric acid for 20 second then rinse then Transbond LR will be applied directly on the fixed retainer and lingual surface of the teeth then light cured.

cleaning the lingual surface using oil free pumice then apply acid etch 35% phosphoric acid for 20 second then rinse then Transbond XT will be applied directly on the fixed retainer and lingual surface of the teeth then light cured.

Sponsors

Cairo University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
TRIPLE (Subject, Investigator, Outcomes Assessor)

Eligibility

Sex/Gender
ALL
Healthy volunteers
Yes

Inclusion criteria

* Patient at the end of an orthodontic treatment requiring the subsequent application of a lingual and palatal fixed retainer * good oral hygiene * medically free

Exclusion criteria

* Facial trauma * onychophagia * habit of biting pencils or pens * tooth mobility

Design outcomes

Primary

MeasureTime frameDescription
Failure rate( detachment rate) of fixed lingual retainerthe patient will be inspected after applying the fixed retainer every month for 6 monthsmeasured by inspection of any detachment partial or complete of the fixed lingual retainer

Countries

Egypt

Contacts

Primary ContactMohamed Saied, BDS
mohamedsaied@dentistry.cu.edu.eg0021003945733
Backup ContactHeba Dehis, lecturer
heba.dehis@dentistry.cu.edu.eg0021020490611

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026