Skip to content

Comparison of Lateral Cephalometric and Cone Beam CT Measurements in Mandibular Symphysis

Comparison of Linear And Angular Measurements in Mandibular Symphyseal Region Using Lateral Cephalometric and Cone Beam CT Images

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05654844
Enrollment
100
Registered
2022-12-16
Start date
2017-06-01
Completion date
2020-12-29
Last updated
2022-12-16

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Measurements in Mandibular Symphysis

Keywords

mandibular symphysis, lateral cephalometry, cone beam CT

Brief summary

The goal of this clinical trial is to compare the linear and angular measurements of the mandibular symphyseal region using lateral cephalometric (LC) and cone beam computed tomography (CBCT) images. The main question it aims to answer are: Is there a significant difference in measurements on lateral cephalometric and cone beam CT? Measurements were made by 3 radiologists, and the intra-class correlation coefficient (ICC) was used to measure interobserver reliability.

Detailed description

The aim of the study is to compare the linear and angular measurements of the mandibular symphyseal region using lateral cephalometric (LC) and cone beam computed tomography (CBCT) images. One hundred patients justifying both LC and CBCT exposures were included. Both lateral cephalometric and CBCT images of the patients were used for angular and linear measurements. Angular measurements included vestibular-concavity, lingual- and tooth-inclination angles. Vestibular and lingual cortical bone and total bone thickness measurements were obtained for the comparison of linear measurements. Three radiologists performed the measurements on 200 images. Comparison of the measurements and the imaging methods were done using paired- and Wilcoxon t-tests. Inter-observer reliability was evaluated with the intra-class correlation coefficient (ICC).

Interventions

RADIATIONLC images

Angular and Linear Measurements were compared in mandibular symphysis region using the LC images

RADIATIONCBCT images

Angular and Linear Measurements were compared in mandibular symphysis region using the CBCT images

Sponsors

Ege University
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
25 Years to 40 Years
Healthy volunteers
Yes

Inclusion criteria

* Patients aged 25 to 40 years with lateral cephalometric and CBCT exposure indication for various reasons and/or dental procedures.

Exclusion criteria

* Patients under 25 and above 40 years of age, with more than single missing mandibular anterior teeth, with implants and/or metal restorations in the mandibular anterior region that may disrupt image quality and thus measurements, prominent asymmetry of the mandibular anterior region, having orthodontic appliances, temporomandibular joint and/or muscle disorders and history of trauma were excluded from the study.

Design outcomes

Primary

MeasureTime frameDescription
Angular measurement-14 weeksVestibular Concavity Angle (VCA) measurements had completed by 3 investigator on both images
Angular measurement-24 weeksTooth Inclination Angle (TIA) measurements had completed by 3 investigator on both images
Angular measurement-34 weeksLingual Inclination Angle (LIA) measurements had completed by 3 investigator on both images
Linear measurement-14 weeksVestibular cortical bone thickness measurements had completed by 3 investigator on both images
Linear measurement-24 weeksLingual cortical bone thickness (LCT) had completed by 3 investigator on both images
Linear measurement-34 weeksTotal bone thickness (TBT) measurements had completed by 3 investigator on both images

Countries

Turkey (Türkiye)

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026