The Reproducibility of Microvascular Flow Imaging in Fibroids and Its Correlation With 2D and 3D Power Doppler Outcomes

The Reproducibility of Microvascular Flow in Fibroids and Its Correlation With 2D and 3D Power Doppler Outcomes: a Prospective Cohort Study

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT05643339
Acronym
MVF
Enrollment
30
Registered
2022-12-08
Start date
2021-02-01
Completion date
2021-12-31
Last updated
2022-12-08

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Fibroid Uterus

Keywords

fibroid, microvascular flow, power doppler

Brief summary

The investigators hypothesized that Macrovascular Flow imaging could contribute to 2D power Doppler and 3D power Doppler in depicting fibroid vascularity. However, data concerning the feasibility and reproducibility of Macrovascular Flow imaging is lacking. Therefore the purpose of our study was to determine 1) the reproducibility of Macrovascular Flow imaging, 2) its correlation with 2D and 3D power Doppler, and 3) penetration depth, in order to investigate the added value for daily clinical practice.

Interventions

DIAGNOSTIC_TESTmicrovascular flow imaging

microvascular flow imaging

Sponsors

Academisch Medisch Centrum - Universiteit van Amsterdam (AMC-UvA)
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
FEMALE
Age
18 Years to 50 Years
Healthy volunteers
No

Inclusion criteria

* one or more uterine fibroids * diameter between 1,5 and 12 cm * fibroid easily recognizable on ultrasound

Exclusion criteria

* younger than 18 years * pregnancy * uterine or cervical malignancy * adenomyosis.

Design outcomes

Primary

MeasureTime frameDescription
reproducibility by inter- and intraobserver agreementDay 1The primary outcome was calculated by the assessment of intercorrelation coefficient (ICC) and its 95% confidence interval (CI) using a two-way mixed model. An ICC value of 0.75-1.00 indicates a good to excellent agreement(19). Bland-Altman plots showed the distribution of data.

Secondary

MeasureTime frameDescription
penetration in centimetersDay 1The penetration was measured along the direction of the ultrasound wave, from the probe to the deepest ultrasound signal visible, both for Microvascular Flow and power Doppler. Differences in ordinal data was tested by Mann Whitney U, non-normal continuous data by Wilcoxon rank test and normally distributed continuous data by a one sample t-test.
architectureDay 1architecture of vessels visible in different regions yes/no.
presence doppler signalDay 1yes/no in different regions