Skip to content

Thoraflex Hybrid and Relay Extension Post-Approval Study

Thoraflex Hybrid and Relay Extension Post-Approval Study

Status
Active, not recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT05639400
Acronym
EXTEND
Enrollment
352
Registered
2022-12-06
Start date
2023-03-17
Completion date
2036-03-01
Last updated
2026-02-06

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Aortic Aneurysm, Aortic Dissection, Thoracic Aortic Aneurysm, Thoracic Aortic Dissection, Thoracic Diseases

Keywords

TEVAR, Frozen Elephant Trunk (FET)

Brief summary

The goal of this observational study is to evaluate the Thoraflex Hybrid device alone and in combination with the RelayPro NBS stent-graft in the treatment of aortic disease affecting the aortic arch and descending aorta with or without involvement of the ascending aorta. Patients who undergo treatment with the Thoraflex Hybrid device with or without extension with a RelayPro NBS stent-graft will be eligible for enrolment and study activities and follow-up regime will follow standard care at each participating site. Participant involvement in the study will last for a total of 10 years from the point at which the Thoraflex Hybrid device is placed.

Interventions

DEVICEThoraflex Hybrid

Thoraflex Hybrid is designed for the open surgical repair of aneurysms and/or dissections in the aortic arch and descending aorta with or without involvement of the ascending aorta. There are two types of Thoraflex Hybrid implants, namely the Plexus 4 and the Ante-Flo versions. Each patient receives one Thoraflex Hybrid device (either the Plexus 4 or Ante-Flo).

DEVICERelayPro NBS

The RelayPro NBS Thoracic Stent-Graft System is an endovascular device intended for treatment of thoracic aortic pathologies such as aneurysms, pseudoaneurysms, dissections, penetrating ulcers and intramural hematoma.

Sponsors

Vascutek Ltd.
Lead SponsorINDUSTRY
Bolton Medical
CollaboratorINDUSTRY

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum

Inclusion criteria

Patient is aged 18 years or older on date of consent. Patient is willing and able to comply with all study procedures and visits. Patient or their next of kin (NOK)/legally designated representative (LDR) has given written informed consent to participate in the study. Patient will undergo treatment with a Thoraflex Hybrid device. If a patient requires an extension procedure due to the extent of aortic disease, a RelayPro NBS Stent-graft should be placed inside the distal end of the previously placed Thoraflex Hybrid device via a retrograde approach. This may be part of the same or a two-stage procedure.

Exclusion criteria

* Patient has any medical, social, or psychological problems that in the opinion of the investigator preclude them from receiving this treatment and the procedures and evaluations pre and post procedure.

Design outcomes

Primary

MeasureTime frameDescription
Primary Safety Endpoint is a composite of the following:The primary safety endpoint will be measured at one-year after the index procedure and again at least 8 months after the (first) extension procedure.* Permanent disabling stroke (mRS \>2 and an increase in at least one mRS category from the individual's pre-stroke baseline, occurring within 30 days of either index procedure or extension and present at 1-year follow-up)\* Note: If a subject dies prior to 1-year follow-up, their last recorded mRS will be considered their final score * Grade 3 spinal cord ischemia (SVS reporting standards) occurring within 30 days of either index procedure or extension * All-cause mortality (within 1 year of either procedure) (\*Per VARC-3, disability assessment using the mRS should be performed between 30 and 90 days after a neurological event with 90 days being optimal. An increased mRS score by itself and in the absence of a neurological event does not constitute stroke.)
Primary Effectiveness Endpoint: Treatment SuccessThe primary effectiveness endpoint will be measured at one-year after the index procedure and again at least 8 months after the (first) extension procedure.Defined as device technical success (of either procedure) with absence of the following at 1-year: * Lesion-related mortality (defined as all deaths occurring within 30 days of, or, prior to discharge, from either the index procedure or the extension procedure or any revision procedures to treat the original lesion(s) and any other deaths adjudicated by Clinical Events Committee as related or probably related to the lesion(s)) * Aortic rupture in the treated segment * Lesion expansion (≥5mm increase from measurement at discharge/within 30 days) * Secondary intervention to address the following: * Stent graft-induced aortic wall injury (SAWI) * Fistula * Type I or III endoleak (see definitions) * Migration * Loss of Patency * Thromboembolic events * Failure of integrity

Secondary

MeasureTime frameDescription
Secondary Safety Endpoints, Absence of the followingThe secondary endpoints will be measured at each follow-up timepoint from discharge/30 days through to 10 years.* All-cause mortality, and * Lesion-related mortality (defined as all deaths occurring within 30 days of, or, prior to discharge, from either the index procedure or the extension procedure or any revision procedures to treat the original lesion(s) and any other deaths adjudicated by Clinical Events Committee as related or probably related to the lesion(s)) * All/any paraplegia/paraparesis defined as SCI (SVS grades 1 to 3) * Any stroke (excluding TIA) * Incidence of Myocardial Infarction * Incidence of Respiratory Failure * Incidence of Renal Failure * Incidence of Bowel Ischemia
Secondary effectiveness endpoints will be reportedThe secondary endpoints will be measured at each follow-up timepoint from discharge/30 days through to 10 years.* Any aortic rupture (treated and untreated segments) * Aortic remodeling in the treated segment(s) * New dissections * Proximal and distal extension of dissections * Any false lumen perfusion (specifying location and if intentional or not) * Fistula formation * All endoleaks * Device migration (measure both \>5mm from position at discharge/within 30 days, and \>10 mm from position at discharge/within 30 days, and requiring secondary intervention) * Device integrity issues (e.g., stent fracture) * All thromboembolic events * Pseudoaneurysms (device-related) * Secondary Interventions * Graft patency (loss of patency will be defined as an opening of \<50% due to, for example, occlusion, stenosis, kinking)

Countries

Austria, France, Germany, Italy, Spain, United Kingdom, United States

Contacts

PRINCIPAL_INVESTIGATORMartin Czerny

University of Freiburg

PRINCIPAL_INVESTIGATORJoseph E Bavaria

Jefferson Health and Sidney Kimmel Medical College

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 7, 2026