Heart Rate Variability Recording With Elite HRV Application and Polar V800

Comparation of Heart Rate Variability Recording With Elite HRV Application and Polar V800 for the Analysis in Healthy Adults

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT05636761
Enrollment
58
Registered
2022-12-05
Start date
2020-04-13
Completion date
2023-02-15
Last updated
2022-12-05

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Reliability and Validity

Keywords

Cardiovascular Risk Factors, Heart rate, Mobile Applications, Autonomic Nervous System

Brief summary

The Elite HRV is a reliable HRV analysis tool and could be a valid option to replace the Polar V800. The objective of study is Comparing the HRV index recorded with the mobile app Elite HRV and with the multisport watch Polar V800. Individuals will submit to two RR interval recordings with a Polar H7 strap that sent the data either to the Polar V800 heart rate monitor or to the Elite HRV app. The volunteers will supine position and breathing spontaneously, and the RR intervals will collect during 25 minutes. Subsequently, without warning the subject, the strap will connect to a nother device, and the second 25minute evaluation was made. The order in which the devices will use is randomized and the HRV indexes will generated via Kubios HRV.

Detailed description

Sample Characterization Before starting the evaluation, an anamnesis will apply, in order to know the individual characteristics of each candidate and verify if he eligible. In addition, anthropometric variables such as weight, height and Body Mass Index will perform to characterize the individuals. Heart Rate Variability (HRV) Heart rate will recorded beat by beat using a heart rate meter (Polar H10, Polar Electro, Kempele, Finland) at a sampling rate of 5 kHz to assess cardiac autonomic modulation. With the chest strap and the receiving and recording device (Elite HRV and Polar V800), the subjects will be positioned in the supine position and remained at rest with spontaneous breathing for 25 min. The laboratory temperature was controlled at 20°C, and data classification was performed in the morning or afternoon, always with a minimum fasting of 2 hours. Participants ask to avoid consuming coffee, chocolate or alcohol and taking medication the night before. Then, without notifying the subject, the strap will be connect to the other receiving device and a new 25-minute collection will perform. For analysis of HRV data, the last 20 minutes of each collection will select. In the future, the first 1000 beat intervals were chosen and only series with more than 95% of sinus beats were included in the study, totaling 1000 consecutive RR intervals. HRV analysis was performed using linear methods, analyzed in the time and frequency domains, according to the guidelines of the Task Force of the European Society of Cardiology and the North American Society of Stimulation and Electrophysiology. STATISTICAL ANALYSIS To determine the difference between the device data, the one-sample t-test will be use. Pearson's correlation coefficient was chosen to evaluate the correlation and it was considered null, weak, moderate, strong, very strong or perfect, when, respectively, r=0; r=0 to 0.3; r=0.3 to 0.6; r=0.6 to 0.9; r=0.9 to 1; r=1. Bland Altman Plots with limits of agreement of 95% were constructed for all indices in order to assess agreement and bias between the different forms of HRV capture. In addition, to analyze the presence of proportion bias, linear regression was used and in case of non-significance, the hypothesis of proportion bias was discarded. We also used Multiple Analysis of Variance (MANOVA) for comparison between Groups (started with Elite HRV versus started with Polar) with Repeated Measures for comparison within Devices (Elite HRV versus Polar). ANOVA one-way with repeated measures for comparisons of Devices (without order comparison) was done to determine p value and effect size. Values of p \<0.05 were considered significant. The statistical package used was the Statistical Package for Social Sciences (SPSS; IBM, Chicago, Illinois, USA), version 26.0.

Interventions

DIAGNOSTIC_TESTHeart rate variability

Collection and Analysis of Heart Rate Variability

Sponsors

University of Sao Paulo
Lead SponsorOTHER

Study design

Observational model
CASE_CROSSOVER
Time perspective
CROSS_SECTIONAL

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* Individuals over 18 years of age * Apparently healthy

Exclusion criteria

* Diagnoses of previously installed heart disease * Continuous medication use that can alter HRV * Use of any substance that could influence the autonomic nervous system, such as caffeinated drinks and foods.

Design outcomes

Primary

MeasureTime frameDescription
similarity of indices of heart rate variability between two devices1 dayassessment of heart rate variability indices from both devices

Countries

Brazil

Outcome results

None listed