Avicena LVDP Validation Study

Assessment of the Vivio System for the Non-Invasive Estimation of Left Ventricular Diastolic Pressure (LVDP) as an Aid in the Diagnosis of Heart Failure

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05633004
Enrollment
406
Registered
2022-12-01
Start date
2021-09-27
Completion date
2022-09-30
Last updated
2022-12-01

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Heart Failure

Brief summary

The purpose of the study is to determine the relationship between non-invasive measurement of left ventricular diastolic pressure (LVDP) using the Vivio System, compared with invasively measured LVDP via direct measurement during left heart catheterization.

Detailed description

Prospective study to document the utility of Vivio in quantifying LVDP, using directly measured LVDP collected during left heart catheterization as the comparator.

Interventions

DEVICEVivio

Non-invasive estimation of Left-Ventricular End Diastolic Pressure (LVEDP)

Sponsors

Avicena LLC
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Intervention model description

Prospective

Eligibility

Sex/Gender
ALL
Age
21 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Adult subjects \>21 years of age. 2. Referred for non-emergent left heart catheterization inclusive of direct measurement of LVDP as part of routine clinical management, to be performed from a femoral or radial access site. 3. Willing and able to participate in all study evaluations and allow access to medical records, including medical testing records. 4. Ability to understand and sign informed consent or have a legally authorized representative to provide informed consent on behalf of the subject.

Exclusion criteria

1. Acute coronary syndrome, or documented MI within a week of scheduled catheterization, cardiogenic shock, or the need for intravenous inotropic or mechanical circulatory support. 2. Carotid pulse is not palpable by a trained study researcher. 3. History of carotid sinus hypersensitivity (fainting in response to minimal touching or positioning of the neck). 4. History of significant or symptomatic carotid artery disease, including TIA, ultrasound evidence of \>60% carotid stenosis, or at the discretion of the investigator; history of carotid artery stenting or surgery. 5. Open skin lesions at the site of Vivio application / examination. 6. Contraindication to placing a catheter in the LV in the judgement of the investigator (e.g., mechanical aortic valve, left ventricular thrombus, etc.). 7. Inability to obtain brachial artery blood pressure.

Design outcomes

Primary

MeasureTime frameDescription
The primary endpoints are the sensitivity and specificity of the Vivio Cuff System for predicting elevated versus non elevated LVEDP as compared to direct measurement of LVEDP in the combined Cath Lab and Healthy Cohorts1 yearThe primary endpoints are the sensitivity and specificity of the Vivio Cuff System for predicting elevated versus non elevated LVEDP as compared to direct measurement of LVEDP in the combined Cath Lab and Healthy Cohorts

Countries

United States

Outcome results

None listed