Skip to content

Comparison Between the Non-powered AEON™ Endostapler and Echelon FLEX™ Powered Plus Stapler With Regards to the Closure of Lung Tissue After Lung Resection in the Presence of Severe Lung Emphysema

Comparison Between the Non-powered AEON™ Endostapler and Echelon FLEX™ Powered Plus Stapler With Regards to the Closure of Lung Tissue After Lung Resection in the Presence of Severe Lung Emphysema: A Prospective Randomized Single-blinded Monocentric Study

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05628415
Acronym
Stapler
Enrollment
19
Registered
2022-11-28
Start date
2022-11-15
Completion date
2025-02-20
Last updated
2025-02-21

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Lung Resection, Postoperative Air Leak

Keywords

severe lung emphysema, AEON™ Endostapler, Echelon FLEX™ Powered plus Stapler, lung-volume-reduction-surgery (LVRS)

Brief summary

Prolonged air leak is reported in up to 60 to 75% of patients after lung operation in the presence of severe lung emphysema. The effect of the non-powered AEONTM Endostapler as compared to the Echelon FlexTM Powered plus stapler on the volume and duration of air leak and on the time to chest drain removal after lung operation in the presence of severe lung emphysema will be investigated in a randomized, prospective, single-blinded clinical trial.

Detailed description

Patients with severe lung emphysema Grad III or IV scheduled for an operation by video-assisted thoracic surgery (VATS) or open method at the Department of Thoracic Surgery at the University Hospital Basel will be pre-screened in terms of inclusion and exclusion criteria. Before the operation, a randomization envelope is opened in the operation room, in which it is specified on which side and with which method the lung tissue will be closed. If bilateral surgery is planned, the other side is automatically closured using the other method. If for example the non-powered AEONTM Endostapler is randomly allocated to the left side, the right side is automatically operated with the Echelon FLEXTM Powered plus Stapler and vice versa. In cases of a unilateral surgery a random stapler as stated in the envelop would be allocated for that side in question. On the day of the operation, postoperative air leak will be measured quantitatively in ml per minute immediately, 2h, 4h, 8h, and 12h after skin closure. Starting on the first postoperative day, this is done twice a day at 8 am and 5 pm until the air leak stops or another surgery must be performed. Cessation of air leak is the case when a value of 0ml/min or two consecutive values under 30 ml/min by use of thoracic drainage Medela- Topaz™ system are read by the investigator.

Interventions

PROCEDURENon-powered AeonTM Endostapler (according to manufacturer medical device classification IIb)

Closure of the left and/or right side of the lung after bilateral or unilateral lung-volume-reduction- surgery is performed with the non-powered Aeon™ Endostapler (Lexington medical) 60-mm and 45-mm. At the end of the operation, two 24F apical chest tubes are placed on each side and are systematically set at -10 cm H2O suction via the Medela- Topaz™ system. Air leak will be measured quantitatively in ml per minute by use of a Medela-Topaz™ system. Cessation of air leak is the case when a value of 0ml/min or two consecutive values under 30 ml/min by use of thoracic drainage Medela- Topaz™ system are read.

PROCEDUREEchelon FLEX™ Powered plus Stapler (according to manufacturer medical device classification IIb)

Closure of the left and/or right side of the lung after bilateral or unilateral lung-volume-reduction- surgery is performed with the Echelon FLEX™ Powered plus Stapler (Ethicon) 60-mm and 45-mm. At the end of the operation, two 24F apical chest tubes are placed on each side and are systematically set at -10 cm H2O suction via the Medela- Topaz™ system. Air leak will be measured quantitatively in ml per minute by use of a Medela-Topaz™ system. Cessation of air leak is the case when a value of 0ml/min or two consecutive values under 30 ml/min by use of thoracic drainage Medela- Topaz™ system are read.

Sponsors

University Hospital, Basel, Switzerland
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
SINGLE (Subject)

Masking description

Only the Patient is blinded to the study. Patients do not know which stapler they are being treated with on which side because they are under anesthesia in the operating room and also do not have access to information regarding the stapler being used afterwards.

Intervention model description

prospective randomized single-blinded monocentric study

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Informed Consent signed by the subject * Patients discussed in the interdisciplinary emphysema treatment board and found to have the indication for a LVRS or patients who meet the criteria in agreement with pneumology recommendation for bilateral or unilateral LVRS with pulmonary emphysema (all morphologies including chronic obstructive pulmonary disease (COPD) GOLD III and IV) or patients operated for other Pathology other than lung emphysema requiring lung resection in the presence of severe lung emphysema.

Exclusion criteria

* non-bullous pulmonary emphysema * Severely impaired carbon monoxide diffusing capacity (≤ 20% of predicted value, One-second capacity (FEV1) ≤ 20% of predicted value with a homogeneous emphysema morphology * Patients with severe pulmonary arterial hypertension (mPAP \> 35 mmHg) and are symptomatic * Significant (i.e. clinically relevant and symptomatic) Coronary Arterial Disease (CAD) * Inability to follow the procedures of the study, e. g. due to language problems, psychological disorders, dementia, etc. of the participant * Enrolment of the investigator, his/her family members, employees and other dependent person * Current enrolment in another clinical trial studying an experimental treatment * Pregnancy

Design outcomes

Primary

MeasureTime frameDescription
Time interval between the end of operation (skin closure) and air leak closure (when the volume is < 30 ml/min measured twice on Medela- Topaz™ drainage system) between the two staplers.End of the operation (0 hours) until timepoint of air leak closure (approx. 3 days to a maximum of 7 days)Comparison of the time interval between the end of operation (skin closure) and air leak closure (when the volume is \< 30 ml/min measured twice on drainage system) between the two staplers.
Change in Volume of air leakEnd of the operation (0 hours), at 2 hours, 4 hours, 8 hours and 12 hours thereafter and from the first postoperative day, at 8 am and 5 pm daily until removal of the chest tubes (approx. 3 days to a maximum of 7 days)Volume of air leak measured following connection of chest tube drainages until removal of the chest tubes

Secondary

MeasureTime frameDescription
Number of postoperative air leaksEnd of the operation (0 hours) until timepoint of air leak closure (approx. 3 days to a maximum of 7 days)Number of postoperative air leaks
Duration of postoperative air leaks until removal of the chest tubes in daysEnd of the operation (0 hours) until timepoint of air leak closure (approx. 3 days to a maximum of 7 days)Duration of postoperative air leaks until removal of the chest tubes in days
Postoperative complications graded using the Clavien -Dindo ClassificationEnd of the operation (0 hours) until timepoint of air leak closure (approx. 3 days to a maximum of 7 days)The Clavien Classification system differentiates in five degrees of severity upon the intention to treat (Grade-I: Any deviation from the normal postoperative course without the need for pharmacological treatment or surgical, endoscopic, and radiological interventions up to Grade-V: Death of a patient).
Number of resurgeries due to prolonged or profuse air leakFrom the day of admittance to hospital to the day of discharge (approx. 7 days)Number of resurgeries due to prolonged or profuse air leak

Countries

Switzerland

Outcome results

None listed