Skip to content

Polish Transcatheter Transfemoral Mitral Valve-in-Valve Implantation (Mitral ViV) Registry

Evaluation of Clinical Outcomes of Transcatheter Transfemoral Mitral Valve-in-Valve Implantation in Polish Population- Observational Multicenter Registry

Status
Recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT05625607
Enrollment
100
Registered
2022-11-23
Start date
2022-10-17
Completion date
2026-05-31
Last updated
2022-11-23

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Bioprosthesis Failure, Heart Failure, Mitral Insufficiency, Mitral Stenosis, Mitral Stenosis With Insufficiency

Keywords

Transcatheter mitral valve replacement, Transcatheter mitral valve implantation, Mitral valve-in-valve, Mitral valve insufficiency, Mitral stenosis, Mitral regurgitation, Bioprosthesis failure, Left ventricle outflow tract obstruction

Brief summary

In recent years increasing number of mitral bioprosthesis implantation, especially in elderly population, is observed. Bioprosthetic valves are associated with a lower risk of thrombotic and bleeding adverse events compared with mechanical prostheses, but their use is limited due to their durability. After years numerous patients may develop bioprosthesis failure, requiring valve reintervention. Significantly burdened ones are oftentimes disqualified or not referred to surgery redo. An emerging treatment method for these patients is transcatheter mitral valve-in-valve implantation as an alternative to re-operation. This technique is applied with the use of devices previously dedicated to transcatheter aortic valve implantation (TAVI). Recent papers prove that transcatheter mitral valve replacement (TMVR) is a safe and effective procedure when performed in a selected group of high-surgical-risk patients. However, data regarding the Polish population are limited. Therefore, the aim of the study is to create a nationwide registry, collecting data from all Polish centers performing TMVR in order to describe the population of patients developing mitral bioprosthesis failure, evaluate their follow-up after TMVR as well as results of the transcatheter valvular intervention and identify potential limitations of the procedure.

Interventions

PROCEDURETranscatheter mitral valve-in-valve implantation

Transcatheter transfemoral mitral valve-in-valve implantation is an alternative for surgery redo in high-surgical-risk patients with bioprosthetic valve failure. The procedure is performed via femoral vein access. By the transseptal puncture (in the postero-inferior part of the interatrial septum) and balloon septostomy, the bioprosthetic valve is introduced through the degenerative valve into the left ventricle. The valve is expanded in the mitral position during rapid ventricle pacing.

Sponsors

National Institute of Cardiology, Warsaw, Poland
CollaboratorOTHER
Medical University of Bialystok
CollaboratorOTHER
University of Opole
CollaboratorOTHER
Medical University of Gdansk
CollaboratorOTHER
Medical University of Silesia
CollaboratorOTHER
Medical University of Lodz
CollaboratorOTHER
Medical University of Warsaw
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Failing surgically implanted mitral bioprosthetic valve demonstrating ≥ moderate stenosis and/or ≥ moderate insufficiency * Qualification for TMVR by decision of the local Heart Team * Patient provided written informed consent

Exclusion criteria

\- Disqualification from TMVR

Design outcomes

Primary

MeasureTime frameDescription
Rate of valve-related dysfunction1 yearMean transvalvular gradient ≥5mmHg; ≥mitral regurgitation; ≥mild paravalvular leak; left ventricle outflow tract obstruction (LVOTO)- (acute hemodynamic deterioration associated with imaging evidence of LVOTO; mean LVOT pressure gradient increasement ≥10 mmHg compared to the baseline value). Endpoint described as n=x (y%).
Rate of all-cause mortality1 yearEndpoint described as n=x (y%).
Rate of hospitalization1 yearHospitalization for valve-related symptoms or worsening congestive heart failure. Endpoint described as n=x (y%).
Rate of neurological events1 yearAll stroke, transient ischemic attack (TIA). Endpoint described as n=x (y%).
Rate of myocardial infarction1 yearEndpoint described as n=x (y%).

Secondary

MeasureTime frameDescription
Rate of device success30 days, 6 month, 1 yearAbsence of procedural mortality or stroke; proper placement and positioning of the device; freedom from unplanned surgical or interventional procedures related to the device or access procedure; continued intended safety and performance of the device. Endpoint described as n=x (y%).
Rate of procedural success30 daysDevice success (either optimal or acceptable), and absence of major device or procedure related serious adverse events, including: A. Death B. Stroke C. Life-threatening bleeding (Mitral Valve Academic Research Consortium scale) D. Major vascular complications E. Major cardiac structural complications F. Stage 2 or 3 acute kidney injury (includes new dialysis) G. Myocardial infarction or coronary ischaemia requiring PCI or CABG H. Severe hypotension, heart failure, or respiratory failure requiring intravenous pressors or invasive or mechanical heart failure treatments such as ultrafiltration or hemodynamic assist devices, including intra-aortic balloon pumps or left ventricular or biventricular assist devices, or prolonged intubation for ≥48 h. I. Any valve-related dysfunction, migration, thrombosis, or other complication requiring surgery or repeat intervention Endpoint described as n=x (y%).
Rate of patient success1 yearI. Device success; II. Patient returned to the pre-procedural setting; III. No rehospitalizations or reinterventions for the underlying condition; IV. Improvement from baseline in symptoms; improvement by ≥1 functional class in New York Heart Association scale. Nominal values from I to IV, where higher value indicates worse outcome; V. Improvement from baseline in functional status; improvement by ≥50 m in 6-min walk test. Continuous values in meters, where higher value indicates better outcome; VI. Improvement from baseline in quality-of-life; improvement by ≥10 in Kansas City Cardiomyopathy Questionnaire. Scores are scaled from 0 to 100, where higher value indicates better outcome. Endpoint described as n=x (y%).
Rate of technical successat 24 hoursAbsence of procedural mortality; successful access, delivery, and retrieval of the device delivery system; successful deployment and correct positioning of the first intended device; freedom from emergency surgery or reintervention related to the device or access procedure. Endpoint described as n=x (y%).

Countries

Poland

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026