Evaluation of a Smartphone Based Diagnostic Tool to Assess Neonatal Jaundice in a Mexican Population

Evaluation of a Smartphone Based Diagnostic Tool to Assess Neonatal Jaundice in a Mexican Population

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05623553
Enrollment
174
Registered
2022-11-21
Start date
2018-07-01
Completion date
2018-08-08
Last updated
2022-11-21

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Jaundice, Neonatal

Brief summary

This corss-sectional study aims to test the performance and accuracy of the Picterus JP screening device in newborns with different skin types.

Detailed description

A descriptive cross-sectional study among 174 newborns was carried out at Hospital Materno-Infantil de Irapuato in Mexico during July and August 2018. The Picterus Calibration Card will be placed on the chest of the newborn with the hole in the card placed over the infant's sternum. A validated smartphone with Picterus JP will be used to collect digital images..

Interventions

Use Picterus Jaundice Pro, a smartphone app that is used to take photo of the newborns skin, where the Picterus calibration card is place.

Sponsors

Norwegian University of Science and Technology Faculty of Medicine and Health Sciences Department of Public Health and Nursing
CollaboratorUNKNOWN
Hospital Materno- Infantil de Irapuato
CollaboratorUNKNOWN
Picterus AS
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
SCREENING
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
0 Days to 14 Days
Healthy volunteers
Yes

Inclusion criteria

* Healthy newborns with or without signs of jaundice * Gestational age \>35 weeks * Age 0-14 days * Birth weight \> 1500 g. * Parents acceptance of their children to participate in the study. * Newborn needing a blood test

Exclusion criteria

* Newborns showing signs or with diagnosis of inborn diseases * Newborn transferred to pediatric ward for any treatment * Newborns who had received phototherapy.

Design outcomes

Primary

MeasureTime frameDescription
Enable high qualitative estimation of bilirubin levels in the blood of newborns using Picterus JP6 monthsEvaluate of smartphone-based diagnostic tool (Picterus JP) for neonatal jaundice in newborns.

Secondary

MeasureTime frameDescription
Correlation with TsB1-2 hoursDemonstrate the correlation among the estimated levels of bilirubin obtained through a smartphone based diagnostic tool with bilirubin serum levels in a population of Mexican neonates.
Correlation with TcB5-10 minutesDemonstrate the correlation among the estimated levels of bilirubin obtained through a smartphone based diagnostic tool with those obtained using a transcutaneous bilirubinometer in a population of Mexican neonates.
Correlation with visual assessment5-10 minutesDemonstrate the correlation among the estimated levels of bilirubin obtained through a smartphone based diagnostic tool with those obtained using visual Kramer scale in a population of Mexican neonates.

Countries

Mexico

Outcome results

None listed