Skip to content

ALknee Follow-up Study of the Cementless ATTUNE Rotating Platform and the Cementless LCS Rotating Platform Knee System

Comparing the Migration and Inducible Displacement Through RSA of the Cementless ATTUNE Rotating Platform and the Cementless LCS Rotating Platform Knee System; A Clinical Randomized Controlled RSA Follow-up Study

Status
Active, not recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT05623215
Enrollment
49
Registered
2022-11-21
Start date
2022-11-10
Completion date
2029-05-31
Last updated
2024-04-18

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Knee Osteoarthritis, Total Knee Arthroplasty, Total Knee Replacement

Brief summary

The cementless ATTUNETM Rotating Platform Knee system was compared in a single-blind, randomized RSA trial to its predecessor, the LCS rotating platform Knee System. In this previous study, 61 knees were subjected to RSA examinations at 1-day and 3, 6, 12 and 24 months postoperative. This study found a promising equal migration of both tibial components and a lesser migration of the femoral component of the ATTUNETM knee system after two years, although with a similar migration rate between year 1 and 2. this raises the question of whether the migration of the prostheses relative to each other will increase or remain the same in the long term. To examine this, a mid-and long-term RSA follow-up to measure migration is necessary. In addition, another new RSA measurement parameter has become known in recent years that may provide an indication of the bonding of the prosthesis to the bone at the time of measurement. This new parameter, called the Induced Displacement (ID) of a prosthesis, measures the position and orientation relative to the bone while the prosthesis is under different loading conditions (e.g., patient in supine or standing position). This means that a large measured difference between these different loading condition measurements would indicate that osseointegration of the prosthesis never occurred or is no longer present. To improve the understanding of the tendency of both prostheses to aseptic loosening after a mid- to long-term follow up, migration over time and inducible displacement analyses are necessary. The primary objective of this study is to accurately compare mid- and long-term migration of two uncemented TKR prostheses. The secondary objectives of this study are to evaluate if inducible displacement can be used as a parameter to detect loose implants, and to compare inducible displacement, clinical and radiological outcome and patient-reported outcomes (PROMS) after a follow-up of 5 and 10 years of two uncemented TKR prostheses.

Interventions

RADIATIONRadiographs of the knee for radiostereometric analysis (RSA)

RSA radiographs will be made 5 and 10 years after the total knee arthroplasty.

Sponsors

Leiden University Medical Center
CollaboratorOTHER
Spaarne Gasthuis
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Healthy volunteers
Yes

Inclusion criteria

In order to be eligible to participate in this study, a subject must meet all of the following criteria: * The Patient participated in the initial study (NL58911.058.16) \[1\]. * The patient is capable of giving informed consent and expressing a willingness to comply with the study.

Exclusion criteria

A potential subject who meets any of the following criteria will be excluded from participation in this study: * The patient underwent a major revision TKR (exchange of the tibial or femoral component). * The patient is unable or unwilling to sign the informed consent specific to this study.

Design outcomes

Primary

MeasureTime frameDescription
Ten year change from baseline migration of the prostheses10 years post TKAMigration is measured and expressed in translations, rotations and MTPM; MTPM is the point of the prosthesis that has moved most.
Change from baseline migration of the prostheses5 years post TKAMigration is measured and expressed in translations, rotations, and MTPM; MTPM is the point of the prosthesis that has moved most.

Secondary

MeasureTime frameDescription
EuroQol 5D-5L (EQ-5D-5L)5 year post TKAA patient reported outcome score for assessing mental well-being by using a score from 0 to 1, with 0 = worse and 1 = best.
Knee injury and Osteoarthritis Outcome Scale Physical Function Short-form (KOOS-PS)5 year post TKAA 7-item patient reported outcome score that measures daily physical functioning by using a score of 0 to 100, with 0 = no problems and 100 = extreme problems.
Oxford-12 Knee Score (OKS)5 year post TKAA 12-item patient-reported outcome score to assess function and pain after total knee arthroplasty. The score uses a score of 0 to 48, with 0 = worse and 48 = best.
Numeric Rating Scale (NRS)5 year post TKAA patient reported outcome score for assessing pain by using a likert scale from 0 to 10, with 0 = no pain and 10 = severe pain)
Anchor questions5 year post TKAA patient reported outcome score for assessing change in functioning and pain since surgery. The outcome is evaluated by use of a likert scale from 1 to 7, with 1 = much deteriorated and 7 = much improved).
Kujala Anterior Knee Pain Scale (AKPS)5 year post TKAA 13-item patient reported outcome score for assessing daily anterior knee pain, by using a score from 0 to 100, with 0 = having anterior knee pain with disabilities and 100 = no signs of anterior knee pain.
Inducible displacement5 years post TKAThe inducible displacement is defined as the difference in translation (MTPM) between a measurement without external force (e.g., supine position) and a measurement with external force (e.g., weight bearing) minus the measurement error.

Other

MeasureTime frameDescription
Complications5 year post TKAComplications during follow-up will be reported

Countries

Netherlands

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026