Skip to content

Clinical Validation and Safety of the AC 12L ECG System Against a Standard of Care 12-Lead ECG (AC 12L ECG)

Clinical Validation and Safety of the AC 12L ECG System Against a Standard of Care 12-Lead ECG (AC 12L ECG)

Status
Recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05617001
Enrollment
200
Registered
2022-11-15
Start date
2022-10-04
Completion date
2024-12-31
Last updated
2024-02-28

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Arrhythmia

Brief summary

AliveCor (www.alivecor.com) has developed an ECG device (KardiaMobile) that interfaces with iOS and Android smartphones and tablets. This ECG consists of a lightweight hardware case with two metal electrodes that can snap onto the back of the phone and a software application. By holding the right finger(s) on the right electrode and the left finger(s) on the left electrode, an electrical circuit is completed and a lead-I, 30 second rhythm strip is created. KardiaMobile and a newer device, KardiaMobile 6L, were approved by FDA for ECG rhythm recording. Recently, AliveCor developed a new device: Kardia 12L to record 12-lead ECGs. However, the data generated from the new device has not yet been validated for accuracy. The specific aim of this study is to evaluate the accuracy and safety of the AC 12L ECG System. The ECGs collected by the AC 12L ECG System will be compared to simultaneous standard- of-care 12-lead ECG, recorded using the GE CardioSoft 12-lead ECG System. The ECGs will be analyzed for accuracy based on statistical difference using root-mean-square error, and cross correlation between the simultaneous 10 second recordings as well as the median beats of all 12 leads.

Interventions

The purpose of this study is to collect clinical validation data to support an FDA submission for a 510(k) for the Kardia 12L hardware which enables the simultaneous diagnostic quality recording of all 6 limb leads and any chest lead. We will be recording both Leads V1 and V2 in a sequential fashion along with the V4 and Limb leads and a simultaneous 12-lead ECG to validate the hardware and a Deep Neural Network model which expands the 5 leads into a complete 12-lead ECG. The 12-lead ECG used for validation of the recordings and the 12-lead synthesis model is the GE Cardiosoft System which is FDA cleared.

Sponsors

University of Oklahoma
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* Male or female patients 18 years or older * Ability to remain supine for a conventional 12 lead AliveCor 12L ECG recording for approximately 15 minutes

Exclusion criteria

* Open chest wounds or recent (\<30 days) surgery to the chest or abdomen * Absence of any limb that would require modification of the lead set-up

Design outcomes

Primary

MeasureTime frameDescription
Agreement on QRS width between Kardia 12L and ECG30 secondsQuantitative analysis on QRS width will be performed on the median-beat ECGs derived from the recorded ECGs from the device as well as 12-lead ECG for each study participant
Agreement on PR interval between Kardia 12L and ECG30 secondsQuantitative analysis on PR interval will be performed on the median-beat ECGs derived from the recorded ECGs from the device as well as 12-lead ECG for each study participant
Agreement on AT interval between Kardia 12L and ECG30 secondsQuantitative analysis on AT interval will be performed on the median-beat ECGs derived from the recorded ECGs from the device as well as 12-lead ECG for each study participant

Countries

United States

Contacts

Primary ContactMichael Stout, RN
michael-h-stout@ouhsc.edu405-271-9060

Outcome results

None listed