Skip to content

Impact of Silicon-based Formulations on Wound Healing of Laser-induced Microscopic Skin Lesions

Impact of Silicon-based Formulations on Wound Healing of Laser-induced Microscopic Skin Lesions

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05614557
Acronym
SPASM11
Enrollment
20
Registered
2022-11-14
Start date
2023-03-21
Completion date
2023-08-31
Last updated
2023-09-06

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Wound Healing

Brief summary

Delayed wound healing is considered a health problem with devastating consequences for patients, healthcare systems, and societies. Over the past 20 years, many other groups, as well as ourselves, have evaluated various alternatives to improve wound healing. Despite this, the scientific evidence demonstrating the efficacy of recently developed treatments is often limited. Stratacel® and Stratamed® are two gels approved by Swissmedic and the FDA for use in improving wound healing. To this end, the efficacy of these formulations has been visually tested by a physician or by patients. Using the most advanced medical technologies (confocal microscopy and LCOCT), this study aims to investigate the effect of these formulations on the healing of human skin. For this research, a total of 20 volunteers will be included in this study. Volunteers will have up to 7 follow-up appointments over 21 days. Each appointment will last approximately 30 minutes and will be used to perform external measurements of skin healing. All volunteers will use the same formulations (Stratacel® and Stratamed®) with the only difference between volunteers being the anatomical area of application of the formulation. This will be determined by chance. The active participation of the participant is requested for the application of the formulations on the skin twice a day during the trial.

Interventions

DEVICEStratacel

Silicone-based formulation registered as a European class IIa, TGA (Therapeutic Goods Administration) and FDA listed Class I medical device (wound dressing).

DEVICEStratamed

Silicone-based formulation registered as a European class IIa, TGA (Therapeutic Goods Administration) and FDA listed Class I medical device (wound dressing).

Sponsors

University Hospital, Geneva
CollaboratorOTHER
Stratpharma AG
Lead SponsorINDUSTRY

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
OTHER
Masking
SINGLE (Outcomes Assessor)

Eligibility

Sex/Gender
ALL
Age
18 Years to 50 Years
Healthy volunteers
Yes

Inclusion criteria

1. Healthy adult volunteers age ≥18 years to 50 years 2. Subjects must be willing and able to participate as required by the protocol. 3. Subjects must be willing and able to provide written informed consent.

Exclusion criteria

1. Evidence of any relevant skin or systemic disease (for example diabetes mellitus, cardiovascular disease, hypertension, chronic or acute skin disease) possibly affecting the wound healing of the test site. 2. Any skin alteration (for example tattoo or scar) on the test site. 3. Test sites with terminal hairs 4. Pregnancy or breastfeeding. 5. History of hypertrophic scars or keloid formation or a similar abnormal wound healing. 6. Intake of any drug which in the evaluation of the investigator may interfere with the interpretation of trial results or are known to cause clinically relevant interferences. 7. Body Mass Index (BMI) \> 36 kg/m². 8. Have any other condition (including drug abuse, alcohol abuse, or psychiatric disorder) that, in the opinion of the investigator, precludes the patient from following and completing the protocol.

Design outcomes

Primary

MeasureTime frameDescription
Measurement of erythema severity via erythema index with and without silicon-based formulations.21+-2 days maximumErythema severity is measured using the erythema index (EI). EI will be evaluated by a Mexameter by means of duplicate measurements per skin area in arbitrary units.

Secondary

MeasureTime frameDescription
Time needed for the scab to fall off21+-2 days maximumTime needed for the scab to fall off will be evaluated through the study of photo documentation conducted thorough the experiment. To obtain the best possible image of the microscopic treatment zones, a DermLite DL4 dermatoscope will be used. The dermatoscope is a non-invasive device, frequently used in dermatology, which allows a better observation of the skin surface by magnifying it.
Volume of microscopic treatment zones (MTZs) and recovery time21+-2 days maximumVolume of the MTZs and time to recovery will be evaluated using confocal microscopy. Either by using RCM or LC-OCT (both non-invasive), a minimum of 3 MTZs per region will be evaluated. MTZs will also be evaluated following the classical protocol of biopsy fullowed by H&E staining.

Countries

Switzerland

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 5, 2026