Comparison of Temperature Using Tracheal Thermometer and Pulmonary Artery Catheter in Adult Patients Undergoing CABG

Comparison of Core Temperature Using Tracheal Thermometer and Pulmonary Artery Catheter in Adult Patients Undergoing Coronary Artery Bypass Graft Surgery

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT05595616
Acronym
TVP
Enrollment
12
Registered
2022-10-27
Start date
2022-09-20
Completion date
2023-08-31
Last updated
2023-09-08

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Coronary Artery Disease

Brief summary

In anesthesia, monitoring of core body temperature is one of important factors. Measurement of temperature using a pulmonary artery catheter is representative one of core temperature measurements. The core temperature by a pulmonary artery catheter is compared with the tracheal temperature by an endotracheal tube with thermometer. This study was designed to confirm the accuracy of the endotracheal tube thermometer.

Detailed description

All patients undergoing general anesthesia are monitored core body temperature. Coronary artery bypass graft surgery needs general anesthesia with endotracheal intubation and insertion of pulmonary artery catheter. Using endotracheal tube with thermometer and pulmonary artery catheter, the investigators will measure tracheal temperature and pulmonary artery temperature every 5 minutes for 1 hour after induction of general anesthesia. Standard monitoring devices (non-invasive BP, electrocardiogram, pulse oxygen saturation) are applied to participants in an operation room, and 1% propofol 1-2 mg/kg and rocuronium 0.8 mg/kg are administered intravenously for induction of general anesthesia. An endotracheal tube with thermometer (Human Endotracheal Tube, Insung Medical Co., Korea) is inserted. After inserting a 9Fr central venous catheter with a pulmonary artery catheter insertion port, core body temperature is measured by a pulmonary artery catheter (Swan-Ganz CCOmbo V, Edwards Lifesciences, Irvine, California, USA). Tracheal temperature will be compared with pulmonary artery temperature by using Bland-Altman method.

Interventions

DEVICEInsertion of tracheal thermometer and pulmonary artery catheter

Endotracheal intubation of endotracheal tube with thermometer (Human Endotracheal Tube, Insung Medical Co., Korea) and insertion of Swan-Ganz catheter

Sponsors

Pusan National University Yangsan Hospital
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Adult patients over 18-year-old undergoing coronary artery bypass surgery

Exclusion criteria

* Emergency surgery

Design outcomes

Primary

MeasureTime frameDescription
Comparison of tracheal temperature versus pulmonary artery temperatureTracheal temperature and pulmonary arterial temperature are measured every 5 minutes for 1 hour after induction of general anesthesia.This study compares core body temperature measured by a pulmonary artery catheter and temperature measured by an endotracheal tube with a thermometer. Additional description\> Time points or intervals are not important factors in this study. The study needs repeated measurements using method A (tracheal thermometer) and method B (pulmonary artery thermometer). Then it compares tracheal temperature with pulmonary artery temperature, and checks the agreement of method A and B.

Countries

South Korea