Skip to content

Effect of RT3D-TEE-guided Mitral Valve Repair on Outcomes in Patients With Degenerative Mitral Valve Disease

Effect of RT3D-TEE-guided Mitral Valve Repair on Outcomes in Patients With Degenerative Mitral Valve Disease

Status
Recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05595226
Acronym
TEEMR
Enrollment
338
Registered
2022-10-26
Start date
2021-12-31
Completion date
2026-12-31
Last updated
2022-10-28

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Degenerative Mitral Valve Disease

Brief summary

The aim of this randomized controlled trial to investigate the effects of Real-time 3D transesophageal echocardiography (RT3D-TEE)-guided mitral valve repair on surgical failure and 1-year reoccurrence of mitral valve regurgitation in patients with degenerative mitral value disease.

Interventions

PROCEDURERT3D-TEE-guided mitral valve repair

RT3D-TEE forms a surgical plan before surgery and 3 to 4 senior doctors with more than 50 cases of mitral valve repair perform the procedure.

Sponsors

Sheng Liu
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

* Diagnosed with chronic primary degenerative mitral regurgitation by the preoperative echocardiogram. * Informed consent was obtained

Exclusion criteria

* Re-operation of mitral regurgitation * Concurrent surgical plan for congenital heart disease, coronary artery bypass grafting, aortic valve surgery, radiofrequency ablation of atrial fibrillation and other cardiac surgeries. * Mitral valve replacement * Unable to undergo TEE

Design outcomes

Primary

MeasureTime frameDescription
Composite events of mitral valve repair failure and 1-year reoccurrence of mitral regurgitation1 yearmitral valve repair failure, 1-year reoccurrence of mitral regurgitation

Secondary

MeasureTime frame
Individual occurrence of composite endpoints of mitral valve repair failure and 1-year reoccurrence of mitral regurgitation1 year
The incidence of secondary transfer, perioperative complications1 year
Intraoperative conditions including extracorporeal circulation time, aortic occlusion time1 year
The recurrence rate of residual mitral valve regurgitation1 year

Countries

China

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026