Use of MiniMed 780G System in Children and Adolescents

Use of MiniMed 780G System in Children and Adolescents, a French Real Life Observational Study

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT05591690
Enrollment
32
Registered
2022-10-24
Start date
2020-11-01
Completion date
2022-08-31
Last updated
2022-10-24

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Diabetes

Keywords

Advanced hybrid closed loop, pediatrics, real-world, time in range

Brief summary

Hybrid closed-loop technology have shown that it improves glycemic control parameters, but the investigators do not have sufficient data at more than 6 months of follow-up, allowing us to describe the effectiveness of these systems in the long term. All MiniMed 780G system users from November 2020 to March 2022 were included (n=32) For every time points, there was a significant difference in Time In Range between the pre-AHCL and post-AHCL. Noted difference were +14.5% and, +10.8% at respectively 3 months and 1 year. No more hypoglycemia were identified. This real-life analysis shows that the algorithm is effective in improvement of metabolic control for T1 diabetic children and adolescents, at one year of follow-up. However, an effect of breathlessness is observed which underlined the need for a solid therapeutic education program.

Interventions

None listed

Sponsors

University Hospital, Montpellier
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
RETROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
No minimum to 18 Years
Healthy volunteers
No

Inclusion criteria

All children with type 1 diabetes in whom a Medtronic G780 closed-loop pump was placed between November 2020 and March 2022 in our center were included.

Exclusion criteria

Participant opposition

Design outcomes

Primary

MeasureTime frameDescription
Glycated hemoglobin1 yearPercentage of glycated hemoglobin measured by the MiniMed 780G system
Time spent in range Level with glucose levels within the norm1 yearTime spent with glucose levels between 70 and 180 mg/dL
Time spent with glucose levels below range1 yearTime spent with glucose levels inferior to 70mg/dL
Time spent with glucose levels above range1 yearTime spent with glucose levels superior to 180 mg/dL