Skip to content

Continuous Glucose Monitoring in Intensive Care Unit

Continuous Glucose Monitoring in Intensive Care Unit

Status
Active, not recruiting
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05585801
Enrollment
500
Registered
2022-10-19
Start date
2022-11-01
Completion date
2026-12-01
Last updated
2026-06-23

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Blood Glucose, Critical Care

Brief summary

Glucose control in ICU patients is challenging and exerts high burden on the nursing staff. Continuous glucose monitors (CGM) are now approved and widely available in the outpatient setting for patients with diabetes mellitus. However, only minimal evidence on CGM performance, reliability and benefit in achieving desired glucose control in the intensive care setting has been gathered so far. The objective of this study is to assess whether the use of CGM helps to maintain blood glucose levels within the time in range recommended for patients in the intensive care. In addition, accuracy of the sensor will be evaluated and compared to measurements of blood glucose by standardized biochemistry methods.

Detailed description

This will be a non-commercial, investigator-driven, active comparator-controlled, randomized, open-label and non-inferiority clinical study to be performed at the Institute for Clinical and Experimental Medicine in Prague. Patients that are being prepared for one of the surgical procedures mentioned below will be asked to participate: 1. pancreas surgery - total or partial pancreas resection 2. orthotopic liver transplantation 3. simultaneous pancreas and kidney transplantation 4. patients with diabetes mellitus undergoing major surgery After obtaining the informed consent, they will be randomized into one of two treatment groups: 1. Study arm with continuous glucose monitor added to standard treatment, where the values obtained by CGM will aid in adjusting the insulin treatment. 2. Control arm with blinded continuous glucose monitor that will be treated according to the standard of care, where the CGM data will be collected in a blind fashion and evaluated after completion of the follow-up. Each surgical group will be randomized and evaluated separately and independently. Continuous glucose monitoring will be initiated after completing the surgical procedure in order to avoid interferences during the procedure. Insulin therapy will be adjusted according to the standard in-house ICU protocol for insulin dose adjustment.

Interventions

DIAGNOSTIC_TESTBlood glucose measurements according to standards of care

Blood glucose will be measured using point of care glucose meter and standard biochemistry methods. Blinded CGM will be applied to obtain continuous glucose values for post-hoc comparison.

Continuous glucose monitor will be used to measure interstitial glucose and aid in guiding the insulin therapy to achieve target blood glucose range of 6-10 mmol/l. In the control group, blood glucose will be measured according to standards of care and a blinded continuous monitor will be used to compare the time i range between the arms.

Sponsors

Institute for Clinical and Experimental Medicine
Lead SponsorOTHER_GOV

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

1. Male or female patients, of 18 to 80 years of age, undergoing one of the following surgical procedures and post-operative care at ICU: 1. pancreas surgery - total or partial pancreas resection 2. orthotopic liver transplantation 3. simultaneous pancreas and kidney transplantation 4. patients with diabetes mellitus undergoing major surgery 2. Patient must have signed the Patient Informed Consent Form.

Exclusion criteria

Any criteria that would disable surgical procedures involved

Design outcomes

Primary

MeasureTime frame
Time in target range of 6-10 mmol/lFrom the time of continuous glucose sensor insertion, which will be performed after admission to postoperative ICU, until the discharge from postoperative ICU, approx. 5-7 days

Secondary

MeasureTime frameDescription
Mean blood glucose levelsFrom the time of continuous glucose sensor insertion, which will be performed after admission to postoperative ICU, until the discharge from postoperative ICU, approx. 5-7 days
Time spent in hyperglycaemia level 1 (glucose levels 10.1-13.9 mmol/l )From the time of continuous glucose sensor insertion, which will be performed after admission to postoperative ICU, until the discharge from postoperative ICU, approx. 5-7 daysAmount of time (%) spent in hyperglycaemia level 1 (glucose levels 10.1-13.9 mmol/l )
Time spent in hyperglycaemia level 2 (glucose levels above 13.9 mmol/l )From the time of continuous glucose sensor insertion, which will be performed after admission to postoperative ICU, until the discharge from postoperative ICU, approx. 5-7 daysAmount of time (%) spent in hyperglycaemia level 2 (glucose levels above 13.9 mmol/l )
Time spent in hypoglycaemia level 1 (glucose levels 3.0-3.8 mmol/l )From the time of continuous glucose sensor insertion, which will be performed after admission to postoperative ICU, until the discharge from postoperative ICU, approx. 5-7 daysAmount of time (%) spent in hypoglycaemia level 1 (glucose levels 3.0-3.8 mmol/l )
Time spent in hypoglycaemia level 2 (glucose levels below 3 mmol/l )From the time of continuous glucose sensor insertion, which will be performed after admission to postoperative ICU, until the discharge from postoperative ICU, approx. 5-7 daysAmount of time (%) spent in hypoglycaemia level 2 (glucose levels below 3 mmol/l )
Glycaemic variability assessed by standard deviation of blood glucose levelsFrom the time of continuous glucose sensor insertion, which will be performed after admission to postoperative ICU, until the discharge from postoperative ICU, approx. 5-7 days
Glycaemic variability assessed by coefficient of variation (%CV)From the time of continuous glucose sensor insertion, which will be performed after admission to postoperative ICU, until the discharge from postoperative ICU, approx. 5-7 days
Daily dose of insulinFrom admission until the discharge from postoperative ICU, approx. 5-7 daysDaily dose of insulin and dosing speed throughout the day
Surgical complicationsFrom admission to postoperative ICU until the discharge from hospital, approx. 10-15 daysSurgical site infections, wound dehiscence, wound leakage
Infectious complicationsFrom admission to postoperative ICU until the discharge from hospital, approx. 10-15 daysPneumonia, abdominal sepsis, urosepsis
Time until discharge from the inpatient careFrom admission to postoperative ICU until the discharge from hospital, approx. 10-15 days

Countries

Czechia

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Jun 24, 2026