Role of Glare and Spectral Filtering on Contrast Sensitivity: A Pilot Study

Role of Glare and Spectral Filtering on Contrast Sensitivity: A Pilot Study

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05582304
Enrollment
40
Registered
2022-10-17
Start date
2022-10-31
Completion date
2022-12-08
Last updated
2024-01-31

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Visual Acuity

Brief summary

This will be a split-plot design, randomized, parallel, double-masked feasibility study to evaluate the role of a test lens on contrast sensitivity with and without glare.

Interventions

DEVICETest Lens

ACUVUE OASYS MAX 1-Day with TearStable Technology and OptiBlue Light Filter

ACUVUE OASYS 1-Day with HydraLuxe Technology

Sponsors

Johnson & Johnson Vision Care, Inc.
Lead SponsorINDUSTRY

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
DOUBLE (Subject, Investigator)

Eligibility

Sex/Gender
ALL
Age
18 Years to 65 Years
Healthy volunteers
Yes

Inclusion criteria

Potential subjects must satisfy all of the following criteria to be enrolled in the study: The subject must: 1. Read, understand, and sign the STATEMENT OF INFORMED CONSENT and receive a fully executed copy of the form. 2. Appear able and willing to adhere to the instructions set forth in this clinical protocol. 3. Be between 18 and 65 (inclusive) years of age at the time of screening. 4. By self-report, habitually wear spherical silicone hydrogel soft contact lenses in both eyes in a daily reusable or daily disposable wear modality (i.e. not extended wear modality). Habitual wear is defined as a minimum of 6 hours of wear per day, for a minimum of 5 days per week during the past 30 days. 5. Possess a wearable pair of spectacles that provide correction for distance vision. 6. The spherical equivalent of the subject's vertex corrected distance refraction must be between -1.00 D and -6.00 D (inclusive) in each eye. 7. The magnitude of the cylindrical component of the subject's vertex-corrected distance refraction must be between 0.00 D and 1.00 D (inclusive) in each eye. 8. The best corrected, monocular, distance visual acuity must be 20/25 or better in each eye.

Exclusion criteria

Potential subjects who meet any of the following criteria will be excluded from participating in the study: The subject must not: 1. Be currently pregnant or lactating. 2. Be currently using any ocular medications or have any ocular infection of any type. 3. By self-report, have any ocular or systemic disease, allergies, infection, or use of medication the investigator believes might contraindicate or interfere with contact lens wear, or otherwise compromise study endpoints, including infectious disease (e.g., hepatitis, tuberculosis), contagious immunosuppressive disease (e.g., Human Immunodeficiency Virus \[HIV\]), autoimmune disease (e.g. rheumatoid arthritis, Sjögren's syndrome), or history of serious mental illness or seizures. See section 9.1 for additional details regarding excluded systemic medications. 4. Have habitually worn rigid gas permeable (RGP) lenses, orthokeratology lenses, or hybrid lenses (e.g. SynergEyes, SoftPerm) within the past 6 months. 5. Be currently wearing monovision or multifocal contact lenses. 6. Be currently wearing lenses in an extended wear modality. 7. Have participated in a contact lens or lens care product clinical trial within 30 days prior to study enrollment. 8. Be an employee (e.g., Investigator, Coordinator, Technician) or immediate family member of an employee (including partner, child, parent, grandparent, grandchild or sibling of the employee or their spouse) of the clinical site. 9. Have clinically significant (grade 3 or higher on the FDA grading scale) slit lamp findings (e.g., corneal edema, neovascularization or staining, tarsal abnormalities or bulbar injection) or other corneal or ocular disease or abnormalities that the investigator believes might contraindicate contact lens wear or may otherwise compromise study endpoints (including entropion, ectropion, chalazia, recurrent styes, glaucoma, history of recurrent corneal erosions, aphakia, moderate or above corneal distortion, herpetic keratitis). 10. Have a history of strabismus or amblyopia. 11. Have fluctuations in vision due to clinically significant dry eye or other ocular conditions. 12. Have had any ocular or intraocular surgery (e.g., radial keratotomy, PRK, LASIK, iridotomy, retinal laser photocoagulation, etc.). 13. Have signs of a contact lens-related corneal inflammatory event (e.g., past peripheral ulcer or round peripheral scar). 14. Have a history of eyelid injury, surgery or procedure that resulted in abnormal eyelid position or movement.

Design outcomes

Primary

MeasureTime frameDescription
Area Under the Curve of Photopic Contrast Sensitivity Function Under Bright Light Conditions (∼120 cd/m2) With a Broadband Glare SourceUp to 2 hours post-fittingPhotopic contrast sensitivity was measured under bright light conditions (\ 120 cd/m2) with a broadband glare source at five spatial frequencies (1.6, 3.2, 8, 16 and 24 cpd) using the University of Georgia system. The area under the log contrast sensitivity function (AULCSF) was derived by first calculating the logarithm of contrast sensitivity as logCS = log10(contrast sensitivity), and then AULCSF was calculated using logCS and the log (base 10) of each spatial frequency based on the trapezoidal rule per eye per subject. The AULCSF was computed by trapezoidal integration of the logarithm of the contrast sensitivity (vertical axis) as a function of the logarithm of spatial frequency (horizontal axis). The unit of the horizontal axis is log(cpd) since spatial frequency is in the unit of cycles per degree (cpd). Although, sensitivity is a unitless parameter, to aid interpretation, the units of AULCSF are described as log(sensitivity)\*log(cpd).

Secondary

MeasureTime frameDescription
Area Under the Curve of Mesopic Contrast Sensitivity Under Dim Light Conditions (∼3 cd/m2) With a Broadband Glare Source.Up to 2 hours post-fittingMesopic contrast sensitivity was measured under dim light conditions (\ 3 cd/m2) with a broadband glare source at five spatial frequencies (1.6, 3.2, 8, 16 and 24 cpd) using the University of Georgia system. The area under the log contrast sensitivity function (AULCSF) was derived by first calculating the logarithm of contrast sensitivity as logCS = log10(contrast sensitivity), and then AULCSF was calculated using logCS and the log (base 10) of each spatial frequency based on the trapezoidal rule per eye per subject. The AULCSF was computed by trapezoidal integration of the logarithm of the contrast sensitivity (vertical axis) as a function of the logarithm of spatial frequency (horizontal axis). The unit of the horizontal axis is log(cpd) since spatial frequency is in the unit of cycles per degree (cpd). Although, sensitivity is a unitless parameter, to aid interpretation, the units of AULCSF are described as log(sensitivity)\*log(cpd).

Countries

United States

Participant flow

Recruitment details

This was a split-plot design with two parallel arms consisting of two randomized lighting conditions (photopic and mesopic). Within each parallel arm, subjects were further randomized in a contralateral fashion to the Test and Control lenses. A total of 40 subjects were enrolled and completed the study.

Participants by arm

ArmCount
Photopic
Subjects assigned bright light conditions (\ 120 cd/m2).
20
Mesopic
Subjects assigned dim light conditions (\ 3cd/m2).
20
Total40

Baseline characteristics

CharacteristicPhotopicMesopicTotal
Age, Continuous37.6 years
STANDARD_DEVIATION 14.14
37.1 years
STANDARD_DEVIATION 13.95
37.4 years
STANDARD_DEVIATION 13.87
Race/Ethnicity, Customized
Asian
1 Participants2 Participants3 Participants
Race/Ethnicity, Customized
Black or African American
1 Participants2 Participants3 Participants
Race/Ethnicity, Customized
White
18 Participants16 Participants34 Participants
Region of Enrollment
United States
20 Participants20 Participants40 Participants
Sex: Female, Male
Female
16 Participants18 Participants34 Participants
Sex: Female, Male
Male
4 Participants2 Participants6 Participants

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
deaths
Total, all-cause mortality
0 / 400 / 40
other
Total, other adverse events
0 / 400 / 40
serious
Total, serious adverse events
0 / 400 / 40

Outcome results

Primary

Area Under the Curve of Photopic Contrast Sensitivity Function Under Bright Light Conditions (∼120 cd/m2) With a Broadband Glare Source

Photopic contrast sensitivity was measured under bright light conditions (\ 120 cd/m2) with a broadband glare source at five spatial frequencies (1.6, 3.2, 8, 16 and 24 cpd) using the University of Georgia system. The area under the log contrast sensitivity function (AULCSF) was derived by first calculating the logarithm of contrast sensitivity as logCS = log10(contrast sensitivity), and then AULCSF was calculated using logCS and the log (base 10) of each spatial frequency based on the trapezoidal rule per eye per subject. The AULCSF was computed by trapezoidal integration of the logarithm of the contrast sensitivity (vertical axis) as a function of the logarithm of spatial frequency (horizontal axis). The unit of the horizontal axis is log(cpd) since spatial frequency is in the unit of cycles per degree (cpd). Although, sensitivity is a unitless parameter, to aid interpretation, the units of AULCSF are described as log(sensitivity)\*log(cpd).

Time frame: Up to 2 hours post-fitting

Population: All randomized subjects regardless of actual treatment and subsequent withdrawal from study or deviation from protocol.

ArmMeasureValue (MEAN)Dispersion
Test (Senofilcon A C3)Area Under the Curve of Photopic Contrast Sensitivity Function Under Bright Light Conditions (∼120 cd/m2) With a Broadband Glare Source1.92 log(sensitivity)*log(cpd)Standard Deviation 0.22
Control (Senofilcon A C3)Area Under the Curve of Photopic Contrast Sensitivity Function Under Bright Light Conditions (∼120 cd/m2) With a Broadband Glare Source1.62 log(sensitivity)*log(cpd)Standard Deviation 0.158
Secondary

Area Under the Curve of Mesopic Contrast Sensitivity Under Dim Light Conditions (∼3 cd/m2) With a Broadband Glare Source.

Mesopic contrast sensitivity was measured under dim light conditions (\ 3 cd/m2) with a broadband glare source at five spatial frequencies (1.6, 3.2, 8, 16 and 24 cpd) using the University of Georgia system. The area under the log contrast sensitivity function (AULCSF) was derived by first calculating the logarithm of contrast sensitivity as logCS = log10(contrast sensitivity), and then AULCSF was calculated using logCS and the log (base 10) of each spatial frequency based on the trapezoidal rule per eye per subject. The AULCSF was computed by trapezoidal integration of the logarithm of the contrast sensitivity (vertical axis) as a function of the logarithm of spatial frequency (horizontal axis). The unit of the horizontal axis is log(cpd) since spatial frequency is in the unit of cycles per degree (cpd). Although, sensitivity is a unitless parameter, to aid interpretation, the units of AULCSF are described as log(sensitivity)\*log(cpd).

Time frame: Up to 2 hours post-fitting

Population: All randomized subjects regardless of actual treatment and subsequent withdrawal from study or deviation from protocol.

ArmMeasureValue (MEAN)Dispersion
Test (Senofilcon A C3)Area Under the Curve of Mesopic Contrast Sensitivity Under Dim Light Conditions (∼3 cd/m2) With a Broadband Glare Source.0.57 log(sensitivity)*log(cpd)Standard Deviation 0.189
Control (Senofilcon A C3)Area Under the Curve of Mesopic Contrast Sensitivity Under Dim Light Conditions (∼3 cd/m2) With a Broadband Glare Source.0.43 log(sensitivity)*log(cpd)Standard Deviation 0.14

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026