Skip to content

Capillary Refill Time Calculated With a Video-assisted Method Has a Better Reproducibility Than Visual Method in Critically Ill Patients

Capillary Refill Time Calculated With a Video-assisted Method Has a Better Reproducibility Than Visual Method in Critically Ill Patients a Prospective Monocentric Study

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05573659
Acronym
EVITREC
Enrollment
59
Registered
2022-10-10
Start date
2022-10-06
Completion date
2023-08-01
Last updated
2025-11-19

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Intensive Care Unit, Mortality, Reliability

Keywords

capillary refill time, intensive care unit, mortality, reliability

Brief summary

Capillary refill time is the time it takes for the skin to regain its initial colour after moderate pressure. It is usually performed on the patient index finger, middle finger or ring finger with the examiner's thumb and index finger for five seconds, three measurements having to be averaged. Capillary refill time has a dependent operator character, but it has been shown to be accurately correlated with 14-day mortality in septic shock, hospitalisation need in pediatric population. The purpose of this project is to show that capillary refill time obtained by a video-assisted method has a better inter- and intra-observer reproducibility than capillary refill time obtained by a visual method.

Interventions

OTHERtime of cutaneous recoloration

In the shortest time possible (less than 3 minutes), realization of three successive measurements of the time of cutaneous recoloration by a pressure by the so-called visual method by two intensivists trained at the CRT of the surgical resuscitation service familiar with the technique of time of cutaneous recoloration. The measurements will be carried out blindly from each other.

OTHERvideo assisted cutaneous recoloration

Compression of the nail bed of the index of the subject studied until whitening of the pressed area, then release, the force will be equivalent to 300 g on a kitchen scale TPA 808S Techwood™ and time of compressions being of 5 seconds. Smartphone camera recording of the procedure (Iphone 7™, Apple Inc., Cupertino, CA). An assistant is in charge of timing the TRC between two tops given by the operator, the tops corresponding to the release of the pressure on the index so the beginning of the TRC and the total recoloration of the bleached area. This wizard records the three results in seconds with the associated tenth of a second.

Sponsors

Centre Hospitalier Universitaire, Amiens
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
OTHER
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Age \> 18 years * hospitalized in ICU * Patient or Family /relative with Inclusion Authorization

Exclusion criteria

* Pregnant or lactating women * Under protection (guardianship, curators, reinforced curators)

Design outcomes

Primary

MeasureTime frameDescription
Variation of measure of capillary refill time in visual assisted capillary refill time group.28 daysVariation of capillary refill time measure between experimentors in visual assisted capillary refill time group.
Variation of measure of capillary refill time in video assisted capillary refill time group.28 daysVariation of capillary refill time measure between experimentors in video assisted capillary refill time group.
Variation of measure of capillary refill time between both groups.28 daysVariation of capillary refill time measure between experimentors between both groups

Countries

France

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026