Skip to content

G7 Dual Mobility With Vivacit-E or Longevity PMCF

Global, Multicenter and Prospective Post-Market Clinical Follow-Up Study of the G7® Dual Mobility Acetabular System With Vivacit-E® or Longevity® Poly Bearing & Instrumentation

Status
Enrolling by invitation
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05548972
Enrollment
358
Registered
2022-09-22
Start date
2023-03-20
Completion date
2037-08-31
Last updated
2025-06-15

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Avascular Necrosis, Dislocation, Hip, Femoral Neck Fractures, Hip Osteoarthritis, Joint Diseases, Revision Surgeries, Rheumatoid Arthritis, Trochanteric Fractures

Keywords

Total Hip arthroplasty, Revision Hip arthroplasty, Medical device, Safety, Performance, Clinical benefit, G7 Dual Mobility

Brief summary

This study is a global, multi-center, prospective, non-controlled, non-randomized, post-market clinical follow-up study. The main objectives of this study are to confirm the long-term safety, performance, and clinical benefits of the G7 Dual Mobility Acetabular System when used with the Vivacit-E or Longevity polyethylene hip bearing and instrumentation in primary total and revision (total) hip arthroplasty

Detailed description

The G7 Dual Mobility construct offers dislocation resistance without the need to constrain the femoral head, providing stability and high range of motion. Dual Mobility systems decrease the risk of post-operative instability in high-risk patients in both primary and revision arthroplasties. This study will enroll up to 358 hips globally, 179 for the Vivacit-E and 179 for the Longevity polyethylene bearings. From the 179 hips per bearing variant, the study will enroll 60 primary and 119 revision arthroplasty hips. The Longevity bearing variant will only be enrolled in the US, as it is not CE marked and unregistered in the APAC market. Vivacit-E bearings will be enrolled globally. A maximum of 20 study centers will be selected globally. To minimize potential bias and to maximize our ability to assess inter-site differences, each study site will target maximum 24 primary hip arthroplasties and maximum 47 revision hip arthroplasties. Each site is encouraged to enroll both, primary and revision, subjects.

Interventions

DEVICEG7 Dual Mobility with Vivacit-E bearing

hip arthroplasty with G7 Dual Mobility Vivacit-E bearing

DEVICEG7 Dual Mobility Longevity bearing

hip arthroplasty with G7 Dual Mobility Longevity bearing

Sponsors

Zimmer Biomet
Lead SponsorINDUSTRY

Study design

Allocation
NON_RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

* Patient is 18 to 80 years of age, inclusive * Patient is skeletally mature * Patient qualifies for (total) hip arthroplasty based on physical exam and medical history including at least one of the following: * Non-inflammatory degenerative joint disease, including osteoarthritis and avascular necrosis * Rheumatoid arthritis * Dislocation risks * Correction of functional deformity * Treatment of non-union, femoral neck fracture, and trochanteric fractures of the proximal femur with head involvement, unmanageable by other techniques * Revision procedures where other treatment or devices have failed. * Patient is willing and able to complete scheduled follow-up evaluations as described in the protocol and Informed Consent * Patient, or the patient's legally authorized representative (LAR), has participated in the Informed Consent process and is willing and able to sign an IRB/EC approved Informed Consent

Exclusion criteria

* Patient is septic, has an active infection or has osteomyelitis at the affected joint * Patient has significant osteoporosis as defined by treating surgeon * Patient has metabolic disorder(s) which may impair bone formation * Patient has osteomalacia * Patient has distant foci of infections which may spread to the implant site * Patient has rapid joint destruction, marked bone loss or bone resorption apparent on pre-operative radiographs * Patient underwent contralateral THA within 3 months of planned index procedure or has a contralateral THA planned within 3 months of the index procedure * Patient is undergoing simultaneous bilateral THA * Patient has vascular insufficiency, muscular atrophy at the implant site or neuromuscular disease which are likely to jeopardize the outcome of the surgery. * Patient has any concomitant disease which is likely to jeopardize the functioning or success of the implant * Patient is known to be pregnant * The patient is in a vulnerable population group such as: * a prisoner * a known alcohol or drug abuser * mentally incompetent or unable to understand what participation in this study entails

Design outcomes

Primary

MeasureTime frameDescription
Survival of the implant system10 yearsSurvival of the implant system based on removal of the study device
Safety of the implant system10 yearsSafety of the system will be assessed by monitoring the frequency and incidence of adverse events. Relation of the events to implant, instrumentation and/or procedure should be specified.

Secondary

MeasureTime frameDescription
Modified Harris Hip Score10 yearsThe modified Harris Hip Score measures pain, function and functional activities using a self assessment. The overall score runs from 0-100 with 100 representing the best outcome.
Oxford Hip Score10 yearsThe Oxford Hip Score measures pain and function using a self assessment. The overall score runs from 0-48 with 48 representing the best outcome.
EQ-5D-5L10 yearsThe EQ-5D-5L measures the quality of life using a self assessment. The questionnaire includes 5 dimensions: mobility, self-care, usual activities, pain/discomfort, and anxiety/depression.
Radiographic Assessment5 yearsX-ray evaluation to find significant radiographic findings such as radiolucency, osteolysis, atrophy, hypertrophy, component migration, device fracture, heterotopic ossification, etc

Countries

Belgium, Italy, South Korea, United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026