Skip to content

Artificial Intelligence Supported Intraoral Scanning.

Comparison of Dental Arch Surface Scanning With and Without AI Support: A Methodological Study

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05545696
Enrollment
21
Registered
2022-09-19
Start date
2021-09-01
Completion date
2021-12-05
Last updated
2022-09-19

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Impression Technic, Dental

Keywords

intraoral scanner, digitalization, Artificial intelligence

Brief summary

Digitization (automation) of production stages with Computer-Aided Design and Computer-Aided Manufacturing (CAD/CAM) technologies has led to a digital revolution in dentistry, as in many other fields of the industry. In current dentistry, the digitalization process can be defined as direct and indirect workflow. The clinical reliability and success of the indirect digital workflow made possible by these technologies have been proven by scientific studies. With the development of intraoral scanners (IOS), a virtual model is obtained by direct digitalization. This method eliminated the conventıonale impression and dental cast model steps required for indirect digitalization. Intraoral scanners are used as an alternative to convantıonal impressions in single and short edentulous cases. It has already been emphasized that direct digitalization is a reliable alternative to the conventional impression method, as the clinical applicability, accuracy, and precision of the manufactured restorations have been scientifically verified. Therefore, the clinical use of direct digitalization is increasing (exponentially) day by day, and new upgraded versions of software, along with various modifications for the hardware equipment, are being developed. Integrating artificial intelligence (AI) supported software into the intraoral scanning process can be seen as the beginning of a new era for direct digitalization. Therefore the aim of this study is to evaluate the effect of artificial intelligence on the scanning time, the amount of data collected, and the image accuracy obtained.

Detailed description

It was planned intraoral scanning (3Shape TRIOS A/S, Copenhagen, Denmark) of the participants' mandible (n=21) with artificial intelligence (AI on) and without artificial intelligence (AI off). Reference equilateral triangles for scanning were digitally designed and produced with a 3D printer. Then these triangles bonded to the buccal surfaces of #34, #44, and the lingual surfaces of #36#46 teeth. The lower jaw of each participant was scanned by the same operator, in line with the recommended scanning protocol. Furthermore, scanning was performed randomly, with AI on and off. The IOS software automatically recorded the data required for quantitative comparing the scanning time and the obtained images (TRIOS Scanning Version 1.18.310, 3Shape A/S). In order to compare the scanning effectiveness between the methods, the area data of the digital images of the triangular objects obtained during both scans were calculated in a computer environment with reverse engineering software (Geomagic design X version 2016.1.0, 3D Systems Inc. Rock Hill, SC).

Interventions

DEVICEAI on algorithm

The mandibles of the participants were scanned with ''AI on'' scanning in line with the recommended scanning protocol. All scans were performed by the same operator.

DEVICEAI off algorithm

The mandibles of the participants were scanned with ''AI off'' scanning in line with the recommended scanning protocol. All scans were performed by the same operator.

Sponsors

Hacettepe University
CollaboratorOTHER
Kıvanç Akça
Lead SponsorOTHER

Study design

Allocation
NON_RANDOMIZED
Intervention model
PARALLEL
Primary purpose
BASIC_SCIENCE
Masking
TRIPLE (Subject, Investigator, Outcomes Assessor)

Eligibility

Sex/Gender
ALL
Age
18 Years to 44 Years
Healthy volunteers
Yes

Inclusion criteria

* Completed growth and development * Good oral hygiene habits and healthy periodontal status. * Absence of missing teeth in mandibula (or no teeth loss in mandibular) * Signing of the informed consent form * No temporomandibular joint (TMJ) disorder

Exclusion criteria

* Volunteers who are not fulfilling the inclusion criteria

Design outcomes

Primary

MeasureTime frameDescription
Scanning time and collected dataduring the intraoral scanningThe scanning time (in minutes and seconds) and the amount of collected data (as the count of images), automatically recorded by the intraoral scanning software, will be used to compare the two scanning methods.

Secondary

MeasureTime frameDescription
Surface area measurment of trianglesthrough study completion, an average of 2 weeksThe area data of the triangular objects obtained during both scans were calculated in a computer environment with reverse engineering software.

Countries

Turkey (Türkiye)

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026