Skip to content

Measurement of the Diaphragm Loading During the Training With a IMT Device

Measurement of the Diaphragm Loading During the Training With a Inspiratory Muscle Trainer Device

Status
Recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT05542069
Enrollment
10
Registered
2022-09-15
Start date
2024-02-06
Completion date
2025-03-30
Last updated
2024-09-19

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Sports Physical Therapy

Brief summary

It is well known that the the training with the IMT device increases the Maximal Inspiratory Pressure. Nonetheless, there are doubts about which muscles are involved during this training. The aim of this study is to determine the diaphragm loading of healthy subjects during the training with a IMT device from a low . Therefore, each subject will be monitored using esophageal and gastric manometry.

Detailed description

This study has a quasi-experimental design. The investigators will recruit ten healthy adult volunteers without anticoagulation or esophageal lesions, after signing a consent form. After checking the appropriate correct position of each catheter, each subject will use the IMT device throughout different randomized loads (percentages of the maximal inspiratory pressure, counting by tens from 10% to 100%). FluxMed® GrT MBMed respiratory mechanic monitor will be used. Each percentage of resistive load will be maintained for 5 inspirations. Meanwhile, an operator will register the esophageal pressure,the gastric pressure and the transdiaphragmatic pressure. Diaphragm collaboration in each percentage of resistive load will be determine by calculating the relation between the gastric pressure and the transdiaphragmatic pressure (∆Pgas/∆Pdi).

Interventions

DEVICEThreshold IMT (Inspiratory muscle trainer) by Philips

Apply a resistive load with the IMT device according the maximal inspiratory pressure of each subject.

Sponsors

Clínica Basilea
Lead SponsorOTHER

Study design

Observational model
OTHER
Time perspective
CROSS_SECTIONAL

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* older than 18 years * healthy subjects

Exclusion criteria

* without anticoagulation * without esophageal lesions * without airway lesions * without spirometry alterations

Design outcomes

Primary

MeasureTime frameDescription
Diaphragm intervention during a certain percentage of resistive load with a IMT device1 yearThe diaphragm intervention is determined by the relation of the gastric pressure and the transdiaphragmatic pressure

Countries

Argentina

Contacts

Primary ContactAmelia Matesa, PT
ameliamatesa@gmail.com541159567515

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026