Comparability of Transesophageal Echocardiography and FloTrac/Vigileo System Three Different Positions

Comparability of Transesophageal Echocardiography and Continuous Mini-invasive FloTrac/Vigileo System (© Edwards Lifesciences) for the Determination of Cardiac Output in Three Different Positions During General Anesthesia

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT05508711
Enrollment
40
Registered
2022-08-19
Start date
2021-10-01
Completion date
2022-06-30
Last updated
2022-08-19

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cardiac Output

Keywords

Cardiac output monitoring, Mini-invasive

Brief summary

The use of cardiac output monitoring to guide intraoperative fluid management and inotropic drugs as part of a hemodynamic therapy algorithm reduce the complication rate in major abdominal surgery. The FloTrac/Vigileo system (© Edwards Lifesciences) (Edwards Lifesciences, Irvine, CA) device estimate cardiac output by using arterial pulse contour analysis. The accuracy of FloTrac/Vigileo have been proven in patients with normal cardiac index. Most of studies regarding FloTrac/Vigileo were performed in patients in horizontal supine position, which is not usually the reality in the operation theater during abdominal surgery. Therefore, the investigators realized this monocentric prospective clinical trial to study the accuracy and trending ability of the fourth generation FloTrac/Vigileo system cardiac output estimation in three different positions (horizontal supine, Trendelenburg and reverse Trendelenburg positions) in anesthetized patients undergoing elective major abdominal surgery. The reference method of cardiac output measurement used was the transesophageal echocardiography.

Interventions

DEVICEFloTrac/Vigileo system (© Edwards Lifesciences) (Edwards Lifesciences, Irvine, CA) device

Concomitant cardiac output measurement with transesophageal echocardiography and with the FloTrac/Vigileo system (© Edwards Lifesciences) (Edwards Lifesciences, Irvine, CA) device in 3 different positions (horizontal supine, Trendelenburg and reverse Trendelenburg position).

Sponsors

Université Libre de Bruxelles
Lead SponsorOTHER

Study design

Observational model
OTHER
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* patients scheduled for elective pancreatic, bladder or liver surgery requiring invasive monitoring and Trendelenburg position during the procedure

Exclusion criteria

* age under 18 years * weight under 40 kg * preoperative left ventricular ejection fraction (LVEF) less than 45% * severe heart valve disease * known intra-and/or extracardiac shunt * pulmonary hypertension * preoperative circulatory shock with need for hemodynamic inotropic support * redo surgery * pregnancy

Design outcomes

Primary

MeasureTime frameDescription
To verify the FloTrac/Vigileo's ability to estimate cardiac output (L/min) in horizontal supine position.BaselineTo study the fourth generation FloTrac/Vigileo system accuracy to estimate cardiac output (L/min) in horizontal supine position in anesthetized patients undergoing elective major abdominal surgery. The reference method of cardiac output (L/min) measurement used was the transesophageal echocardiography. The two cardiac output measurement techniques were assessed using Bland-Altman method.
To verify the FloTrac/Vigileo's ability to estimate cardiac output (L/min) in Trendelenburg position.BaselineTo study the fourth generation FloTrac/Vigileo system accuracy to estimate cardiac output (L/min) in Trendelenburg position in anesthetized patients undergoing elective major abdominal surgery. The reference method of cardiac output (L/min) measurement used was the transesophageal echocardiography. The two cardiac output measurement techniques were assessed using Bland-Altman method.
To verify the FloTrac/Vigileo's ability to estimate cardiac output (L/min) in reverse Trendelenburg position.BaselineTo study the fourth generation FloTrac/Vigileo system accuracy to estimate cardiac output (L/min) in reverse Trendelenburg position in anesthetized patients undergoing elective major abdominal surgery. The reference method of cardiac output (L/min) measurement used was the transesophageal echocardiography. The two cardiac output measurement techniques were assessed using Bland-Altman method.