Electrical Stimulation With Different Currents and Electromagnetic Fields

Effects on Isometric Force Induction, Tolerance and Fatigue of Neuromuscular Electrical Stimulation and High Intensity Focused Electromagnetic Field in Healthy Subjects

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05500300
Enrollment
30
Registered
2022-08-15
Start date
2022-08-22
Completion date
2022-12-01
Last updated
2022-08-15

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Healthy

Keywords

Electrical stimulation, Muscle Strength, Fatigue, Assessments, pain, Electromagnetic Fields, Physiotherapy

Brief summary

Muscle strength is the amount of force generated by muscle contraction. It could be measured with an isometric dynamometer. This is a validated tool that could be used to measure Maximal Voluntary Isometric Contraction (MVIC) and Maximal Electrical Induced Contraction (MEIC). It is claimed that higher MEIC values will result in more force gained. If a current is more tolerated it will be easier to achieve better MEIC values. Tolerance to an electrical stimulation could be measured with the Visual Analogue Scale (VAS). A ratio between Normalized MEIC / VAS is often used, implying that the current is better with a higher ratio. Muscle fatigue is defined as a temporary loss or decrease in force-generating ability due to previous contractions. It is claimed that medium frequency neuromuscular electrical stimulation (NMES) generates more fatigue than low frequency currents. Aussie is a medium-frequency alternating current, sinusoidal waveform, 1 KHz carrier frequency. Neo-Russian is a medium-frequency current, rectangular biphasic symmetrical waveform, 2,5 KHz carrier frequency. Rectangular Biphasic symmetrical (RBS) waveform is a type of Low Pulsed Current (LPC), claimed to be better than classical Russian Current. Purpose: As it has been claimed that LPC is better in MEIC and tolerance, the aim of this study is to compare it with two newer medium frequency currents in terms of MEIC, tolerance and fatigue. Methods: Thirty male subjects, right leg dominant, will receive randomly the 3 types of electrical stimulation. Before that, the MVIC will be measured for data normalization. The MVIC and MEIC will be measured with an isometric dynamometer. In both measurements, subjects will be asked to perform three reps (5 sec work x 120 sec rest) and the best one will be used. Whenever the third one was the best, additional measurements will be taken until a decrease in torque will be obtained to determine the maximum. To apply Aussie electrical stimulation, an Aussie Sport (Ibramed) will be used. To apply Neo-Russian, a Neurodyn III (Ibramed) will be used. To apply RBS, a Genesy (Globus) will be used. The VAS will be used to assess tolerance to each treatment. One week later, the subjects will receive, randomly, a fatigue protocol that consists in 21 reps (5 sec work x 5 sec rest) of electrical stimulation with the three types of current. The data will be normalized with the MVIC and the reps equal or below 50 % of the first rep will be considered as a fatigue rep.

Interventions

Subjects will receive Neo-Russian electrical stimulation with three reps (5 sec work x 60 sec rest), and the Maximal Electrical Induced Contraction (MEIC) will be measured. They will be asked how uncomfortable the stimulation was, using Visual Analogue Scale (VAS). One week later, subjects will receive a fatigue protocol that consists in 21 reps (5 sec work x 5 sec rest), and the Maximal Electrical Induced Contraction (MEIC) will be measured for each contraction.

DEVICEAussie

Subjects will receive Aussie electrical stimulation with three reps (5 sec work x 60 sec rest), and the Maximal Electrical Induced Contraction (MEIC) will be measured. They will be asked how uncomfortable the stimulation was, using Visual Analogue Scale (VAS). One week later, subjects will receive a fatigue protocol that consists in 21 reps (5 sec work x 5 sec rest), and the Maximal Electrical Induced Contraction (MEIC) will be measured for each contraction.

DEVICERBS

Subjects will receive RBS electrical stimulation with three reps (5 sec work x 60 sec rest), and the Maximal Electrical Induced Contraction (MEIC) will be measured. They will be asked how uncomfortable the stimulation was, using Visual Analogue Scale (VAS). One week later, subjects will receive a fatigue protocol that consists in 21 reps (5 sec work x 5 sec rest), and the Maximal Electrical Induced Contraction (MEIC) will be measured for each contraction.

DEVICERBS-IPI

Subjects will receive RBS-IPI electrical stimulation with three reps (5 sec work x 60 sec rest), and the Maximal Electrical Induced Contraction (MEIC) will be measured. They will be asked how uncomfortable the stimulation was, using Visual Analogue Scale (VAS). One week later, subjects will receive a fatigue protocol that consists in 21 reps (5 sec work x 5 sec rest), and the Maximal Electrical Induced Contraction (MEIC) will be measured for each contraction.

DEVICEHIFEM

Subjects will receive HIFEM electrical stimulation with three reps (5 sec work x 60 sec rest), and the Maximal Electrical Induced Contraction (MEIC) will be measured. They will be asked how uncomfortable the stimulation was, using Visual Analogue Scale (VAS). One week later, subjects will receive a fatigue protocol that consists in 21 reps (5 sec work x 5 sec rest), and the Maximal Electrical Induced Contraction (MEIC) will be measured for each contraction.

Sponsors

Maimonides University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
BASIC_SCIENCE
Masking
QUADRUPLE (Subject, Caregiver, Investigator, Outcomes Assessor)

Intervention model description

30 male subjects will receive 4 types of electrical stimulation (Aussie, Neo-Russian, Rectangular biphasic symmetric waveform, Rectangular biphasic symmetric waveform with intra-pulse interval) and High Intensity Focused Electromagnetic Field (HIFEM) in a randomized order. Maximal voluntary isometric contraction (MVIC) and maximal elicited induced contraction (MEIC) will be measured with an isometric dynamometer. The best rep will be used. Whenever the third one is the best, additional measurements will be taken until a decrease in torque is obtained to determine the maximum. MVIC will be used for data normalization. The Visual Analogue Scale (VAS) will be used to assess tolerance to treatment. One week later, subjects will receive, randomly, a fatigue protocol with the 4 types of electrical stimulation and the HIFEM, which consists in 21 reps. A fatigue index (FI) will be calculated.

Eligibility

Sex/Gender
MALE
Age
18 Years to 30 Years
Healthy volunteers
Yes

Inclusion criteria

* Healthy volunteers * Male * Right leg dominant * Exercising regularly

Exclusion criteria

* History of injuries in the right leg * Skin lesions * Having a pacemaker * Having a cardiovascular disease. * Having a neurological disorder. * Exercise 72 h before the procedure.

Design outcomes

Primary

MeasureTime frameDescription
Maximal Voluntary Isometric Contraction (MVIC)Day 1Force generated by the patient during a maximal voluntary isometric contraction, measured by an isometric dynamometer with load cell and computer interface. The best of the 3 repetitions will be considered. Whenever the third one is the best, additional measurements will be taken until a decrease in torque is obtained in order to determine the maximum. Unit: Newtons (N)
Maximal Electrical Induced Contraction (MEIC)Day 1Force generated in the muscle while applying electrical stimulation and HIFEM, measured by an isometric dynamometer with load cell and computer interface. This data (in Newtons) will be normalized with the MVIC. Unit: percentage of MVIC
Visual Analogue ScaleDay 1Visual Analogue Scale (VAS): Magnitude of pain, marked in a analogue scale by participants, to determine how unpleasant is each type of stimulation (applied in randomized order). Expresed in centimeters. * Minimum value: 0 * Maximum value: 10 * A higher score implicates a worse outcome. VAS wil be evaluated 5 times, 1 per type of stimulation.

Secondary

MeasureTime frameDescription
Fatigue indexDay 7The MEIC decrease between the first and the 21st rep, previously normalized with the MVIC. * Minimum value: -1 * Maximum value: 1 * The lower the value, the greater the fatigue.

Countries

Argentina

Contacts

Primary ContactOscar Ronzio, DHSc PT
ronzio.oscar@maimonides.edu+54119051140

Outcome results

None listed