Skip to content

PV Loop and Pulmonary Hypertension

Non-Invasive Evaluation of Right Ventricular - Pulmonary Arterial Coupling in Children With Elevated Pulmonary Vascular Resistance

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT05484596
Enrollment
65
Registered
2022-08-02
Start date
2020-04-27
Completion date
2025-04-30
Last updated
2023-09-26

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Pulmonary Vascular Resistance Abnormality

Keywords

pulmonary vascular resistance, pediatric, VA uncoupling

Brief summary

The right ventricular (RV) systolic function is a key determinant of outcome in patients with pulmonary hypertension and elevated pulmonary vascular resistance. As the pulmonary artery pressure and vascular resistance increase (i.e. RV afterload) in these patients, so does the right ventricular contractility in an attempt to maintain cardiac output. This is response of a ventricle to its afterload is termed ventriculo-arterial (VA) coupling. However, there is a limit to this increase in contractility after which VA uncoupling occurs ultimately leading to decrease cardiac output and right ventricular failure. The accepted gold standard for measurement of VA coupling is the ratio of the end systolic ventricular elastance (Ees) to the end systolic arterial elastance (Ea) measured invasively via high fidelity conductance catheters during cardiac catheterization. In this study, the aim is to devise a non-invasive scoring system that can identify VA uncoupling in patients with elevated pulmonary vascular resistance using echocardiography, cardiac MRI, cardiopulmonary exercise testing and brain natriuretic peptide levels. The hypothesis is that a group of morphologic and functional variables obtained noninvasively can differentiate an RV with VA coupling from that with VA uncoupling.

Interventions

PROCEDUREMeasuring VA Coupling

Subjects will undergo clinically indicated investigations and tests. The research part of the study is measuring the VA coupling using high fidelity catheters. That is expected to increase the duration of the cardiac catheterization for 30 minutes.

Sponsors

University of Minnesota
CollaboratorOTHER
Hythem Nawaytou
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
1 Years to 21 Years
Healthy volunteers
No

Inclusion criteria

* Children 1-21 years of age * Patients referred for cardiac catheterization for hemodynamic evaluation due to concern for pulmonary hypertension * Structurally normal heart

Exclusion criteria

* Pulmonary hypertension secondary to pulmonary venous hypertension defined as pulmonary capillary wedge pressure of more than or equal to 15mmHg * Pulmonary hypertension secondary to mixed pulmonary arterial and venous hypertension * Patient will be excluded from performing an MRI if they have: claustrophobia, metal implants or allergy to contrast * Patients will be excluded from performing a cardiopulmonary exercise test (CPET) if they are: 1) less than 8 years or 2) unable to follow instructions to run on a treadmill.

Design outcomes

Primary

MeasureTime frameDescription
Identify echocardiographic measurements of right ventricular systolic function and pulmonary blood flow and their cutoff values contemporaneous that can identify VA uncouplingwithin one week of measurement of ventriculo-arterial coupling ratio during cardiac catheterizationYes/No result: Can echocardiographic measurements allow non-invasive identification of VA uncoupling (defined as Ees/Ea \<0.805). Three ratios: tricuspid annular plane systolic excursion to the pulmonary artery acceleration time, right ventricular free wall strain to the pulmonary artery acceleration time and, right ventricular fractional area change to the pulmonary artery acceleration time.
Identify cMRI measurements of right ventricular systolic function and pulmonary blood flow and their cutoff values contemporaneous that can identify VA uncoupling.within one week of measurement of ventriculo-arterial coupling ratio during cardiac catheterizationYes/No result: Can cMRI measurements allow non-invasive identification of VA uncoupling (defined as Ees/Ea \<0.805). Two ratios: right ventricular ejection fraction to right ventricular end systolic volume and right ventricular ejection fraction to pulmonary artery acceleration time (by echocardiography).
Identify 6-minute walk distance cutoff that can identify VA uncouplingwithin one week of measurement of ventriculo-arterial coupling ratio during cardiac catheterizationYes/No: Can 6-minute walk distance identify VA uncoupling (defined as Ees/Es\<0.805)
Identify brain natriuretic peptide cutoff value that can identify VA uncouplingwithin one week of measurement of ventriculo-arterial coupling ratio during cardiac catheterizationYes/No: Can brain natriuretic peptide identify VA uncoupling (defined as Ees/Es\<0.805)

Countries

United States

Contacts

Primary ContactBrittany Faanes, MPH, CCRP
grego318@umn.edu612-625-5929
Backup ContactJasmine Becerra, BS
jasmine.becerra@ucsf.edu415-476-2649

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026