Ventricular Tachycardia Mechanisms

Ventricular Tachycardia Substrate Mechanisms Revealed by Local Repolarization and Conduction Parameters

Status
Recruiting
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05478213
Enrollment
10
Registered
2022-07-28
Start date
2022-10-25
Completion date
2027-05-01
Last updated
2026-06-30

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Ventricular Tachycardia

Keywords

Ventricular tachycardia ablation

Brief summary

The purpose of this study is to understand why certain hearts have ventricular arrhythmias and help identify areas of the heart that cause arrhythmias. There is still a significant gap in understanding why ventricular arrhythmias occur. This study will examine the electrical properties of the heart tissue to understand how these arrhythmias occur, and hopefully identify areas that might lead to ventricular arrhythmias. The hope is that studying this might be able to improve outcomes during ventricular tachycardia (VT) ablations.

Detailed description

Ventricular tachycardia (VT) ablation remains the cornerstone treatment for drug refractory VT. Previous studies have reported success rate of VT ablation ranging from 23 to 49%. Despite improvements in mapping and catheter technology, there is a high recurrence rate and numerous patients who fail VT ablation. Reasons for failure in VT ablation include the inability to identify critical areas of myocardium responsible for VT and hemodynamic instability of VT during mapping. Several studies have attempted to study electrical properties of cardiac tissues to identify potential circuits in sinus rhythm avoid mapping during unstable VT. This includes mapping fractionated electrical potentials, isochronal late activation mapping (ILAM), and ablation of low voltage regions. However, these techniques have yielded modest improvement in success rates with poor specificity of identifying important regions. Monophasic action potentials (MAP) demonstrate cellular action potential of the myocardium. Recent evidence suggests that changes in MAP morphology can predict sudden cardiac death by ventricular arrhythmias. However, cellular activation has not been studied in VT. The researchers of this study propose that MAP signals can better elucidate electrophysiological characteristics of the myocardium, and thus identify sites critical to VT. During a standard of care VT ablation, the researchers will use the MAP catheter to study cellular action potential of the ventricular myocardium, which cannot be done on traditional catheters. The design of this catheter is similar to other diagnostic catheters that are currently used for VT ablation. The MAP catheter is a bipolar catheter, two with electrical poles at the distal tip. The catheter is placed on the myocardium (similar to other traditional catheters) and a recording signal is transmitted to the workstation. Using the MAP catheter the will not interrupt or distort any of the standard treatment procedures.

Interventions

DEVICEMonophasic Action Potential (MAP) Catheter

The EasyMap catheter is a temporary quadripolar catheter for recording monophasic action potentials and for intracardiac pacing. During a standard of care VT ablation, the MAP catheter will be used to study cellular action potential of the ventricular myocardium, which cannot be done on traditional catheters. The catheter is placed on the myocardium (similar to other traditional catheters) and a recording signal is transmitted to the workstation. Using the MAP catheter the will not interrupt or distort any of the standard treatment procedures.

Sponsors

Emory University
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
BASIC_SCIENCE
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Diagnosis of ischemic cardiomyopathy * Single or dual chamber implantable cardioverter-defibrillator (ICD)

Exclusion criteria

* Non-Ischemic cardiomyopathy * Contraindication to catheter ablation * Severe peripheral arterial disease or medical condition that prohibit arterial access * Ventricular tachycardia (VT) or sudden cardiac arrest (SCA) within 30 days of acute coronary syndrome or within 90 days of coronary revascularization

Design outcomes

Primary

MeasureTime frameDescription
Waveform MorphologyDuring ablation on Day 1Identification of sites that are critical to reentry of ventricular tachycardia from bystander sites will be performed by analyzing local ventricular activation. Local ventricular action is assessed with waveform morphology and is measured in voltage (mV). The normal range is \>3 mV bipolar and \>8.3 mV unipolar.
Conduction VelocityDuring ablation on Day 1Identification of sites that are critical to reentry of ventricular tachycardia from bystander sites will be performed by analyzing electrophysiological properties. Electrophysiological properties are assessed with conduction velocity, measured in meters per second (m/s).

Secondary

MeasureTime frameDescription
Identify mechanisms of slowed conduction at ILAMDuring ablation on Day 1The mechanisms responsible for slowed conduction at sites that are critical to ventricular tachycardia using monophasic action potential signals will be examined.
Identify surrogate markersDuring ablation on Day 1Surrogate markers for monophasic action potential tracings will be compared to conventional mapping catheters.

Countries

United States

Contacts