Skip to content

AnGiographic Performance With A Sirolimus-elutiNG Balloon in the TrEatment of De Novo CoronaRy Artery Disease

AnGiographic Performance Following PCI With A Sirolimus-elutiNG Balloon in the TrEatment of De Novo CoronaRy Artery Disease: GINGER Study

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05471245
Acronym
GINGER
Enrollment
110
Registered
2022-07-22
Start date
2023-05-23
Completion date
2025-10-08
Last updated
2025-12-03

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Coronary Restenosis

Keywords

QCA, late loss, sirolimus eluting balloon

Brief summary

Evaluate angiographic performance in long lesions of Sirolimus Eluting Balloon Magic Touch by Concept Medical

Detailed description

To assess the angiographic performance of the Magic Touch Sirolimus-Coated Balloon (SCB) at 9 months follow-up after PCI for de novo CAD. Primary end-points: * Late lumen loss (LLL) at the SCB-treated segment within 9 months after the index procedure; * Mean net lumen diameter gain at the SCB-treated segment at 9 months angiographic follow-up. Secondary end-points: * Procedural success defined as both SCB delivery and inflation at the target lesion site with \<30% diameter stenosis (DS) in the SCB-treated segment and distal Thrombolysis In Myocardial Infarction (TIMI) 3 flow; * Peri-procedural myocardial infarction (PMI) defined according to the EXCEL trial (creatinine kinase myocardial band) or Society for Cardiovascular Angiography and Interventions definitions (troponin); * Binary restenosis rate at the SCB-treated segment at 9 months angiographic follow-up; * A Device Oriented Composite End-point (DOCE) and its singular components (cardiac death, any target-vessel myocardial infarction excluding PMI, ischemia-driven target lesion revascularization) in-hospital, within 7 days after PCI; phone follow-up at 30-day (+/- 7 days) and 12 months (+/- 1 month) and a follow-up visit at 9 months (+/- 1 month). Any definite/probable SCB-treated segment thrombosis (in-hospital, within 7 days after PCI and at 30-day, 9-month, 1-year follow-up).

Interventions

DEVICEMagic Touch SCB by Concept Medical Inc.

PCI with drug-coated balloon

Sponsors

Fondazione Evidence per Attività e Ricerche Cardiovascolari ONLUS
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SEQUENTIAL
Primary purpose
TREATMENT
Masking
NONE

Intervention model description

prospective enrolment of long lesions

Eligibility

Sex/Gender
ALL
Healthy volunteers
No

Inclusion criteria

1. Age \>18 years 2. Patients presenting with stable or unstable coronary artery disease (CAD) eligible for percutaneous coronary intervention (PCI) with de novo CAD in one or two separates major epicardial territories and at least one lesion suitable for sirolimus coated balloon (SCB); 3. Reference vessel diameter (RVD) at the SCB target site ≥2.0 mm and ≤4.0 mm (by visual estimation and/or quantitative coronary angiography); 4. Lesion length at the SCB target site ≥25 mm; 5. Successful lesion preparation (full and homogenous pre-dilatation balloon expansion without type C-F dissection and/or TIMI flow=3 at the SCB target site; 6. SCB-target lesion located in the same or other vessels treated by drug-eluting stent (DES) implantation; 7. Patient able to understand and provide informed consent and comply with all study procedures including 9 months angiographic follow-up.

Exclusion criteria

1. Patients participating in another clinical evaluation; 2. Age \<18 years; 3. Cardiogenic shock; 4. Pregnancy or breastfeeding women; pregnancy test, either urine or blood test must be performed within 7 days prior to the index procedure in woman of child-bearing potential, and must not commit to initiating a pregnancy for 12 weeks after implantation, using effective contraception; 5. Thrombus containing lesion; 6. Unprotected left main as a target lesion unless this lesion is treated with a DES and SCB inflated distally or on a branch or on a different vessel; 7. Comorbidities with life expectancy \<6 months; 8. Aorto-ostial target lesion (within 3 mm of the aorta junction); unless this lesion is treated with a DES and SCB inflated distally or on a branch or on a different vessel; 9. Target lesion located within an arterial or saphenous vein graft or distal to a diseased arterial or saphenous vein graft; 10. Every known allergy, intolerance or hypersensitivity to any medication used during the procedure and to drugs recommended after the procedure (e.g. aspirin, clopidogrel, ticagrelor, prasugrel); 11. Severe chronic kidney disease (glomerular filtration rate\<30 ml/min/1.73 m2); 12. Platelet count \<50,000cells/mm; 13. Stroke within the previous 6 months; 14. RVD at the SCB target site \<2.0 mm or \>4.0 mm (by visual estimation and/or QCA); target lesion with RVD larger than 4 mm can be treated with a DES and SCB inflated in other segments of the same or other vessels.

Design outcomes

Primary

MeasureTime frameDescription
late lumen loss at 9 months measured by quantitative coronary angiography18 monthsQCA by core lab
incidence of adverse clinical events18 monthsmyocardial infarction, death, need for revascularization

Countries

Italy

Outcome results

None listed