Skip to content

Quantum Molecular Resonance Effects on Patients With Dry Eye Disease

Quantum Molecular Resonance Effects on Patients With Dry Eye Disease

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05469932
Enrollment
50
Registered
2022-07-22
Start date
2021-02-14
Completion date
2022-12-31
Last updated
2022-07-22

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Dry Eye Syndromes

Keywords

Cornea, Dry Eye, Quantum Molecular Resonance

Brief summary

The Rexon Eye device (Resono Ophthalmic Inc, Trieste, Italy) is a new device based on QMR technology. Quantum Molecular Resonance (QMR) is a technique in which low-intensity, high-frequency electric currents are administered to a biological tissue through contact electrodes. The device applies stimulation to the epidermis of closed eyelids up to the lid margin by means of specially designed goggles. Previous studies have shown that it is relatively safe with high patient satisfaction. Preliminary studies have also shown it is effective for accelerating healing in chronic wounds and treating dry eye symptoms.

Detailed description

In this study, the investigators aim to examine the efficacy of the Rexon eye device for the treatment of dry eye signs and symptoms in a randomized double-blind placebo-controlled fashion among a cohort of prospectively recruited patients with dry eye. The control group will receive a similar application of treatment with the device goggles disconnected from the device, effectively receiving no treatment. The treatment will be performed by research assistants following thorough instruction by the manufacturing company representatives and/or provided material. Participants will be actively questioned on any harms or side effects in every meeting. Outcomes will be assessed based on clinical signs and by validated questionnaires on dry eye symptoms (OSDI). Informed written consent will be obtained from all participants involved in the study prior to enrollment. The goal of the study is to evaluate the Rexon device as a possible additional treatment option for patients with dry eye or to establish it has no added benefit.

Interventions

DEVICERexon device

Rexon device for 20 minutes each session. A total of 4 sessions with one week apart from each other.

Sponsors

Assaf-Harofeh Medical Center
Lead SponsorOTHER_GOV

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
SINGLE (Subject)

Masking description

The patient does not know wheater they are on treatment or placebo arm.

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patients above the age of 18 years * Patients who are willing and able to consent and adhere to the research plan * Patients diagnosed with dry eye or patients who are at risk for dry eye

Exclusion criteria

* Active infection of the eyelid or periorbital area * Patients who are pregnant or lactating * Patients under the age of 18 * Those scheduled for (\<30 days) or immediately after (\<30 days) ocular surgery (excluding cataract and eyelid surgery) * Patient who do not adhere to all four treatment sessions.

Design outcomes

Primary

MeasureTime frameDescription
Change in Ocular Surface Disease Index (OSDI) QuestionnaireAt baseline (pre-intervention) and up to 4 weeks after treatment ends (after-intervention)A validated questionnaire that assess the symptoms of ocular irritation in dry eye disease. and how they affect functioning related to vision. This 12-item questionnaire assesses dry eye symptoms and the effects it has on vision-related function in the past week of the patient's life. The questionnaire has 3 subscales: ocular symptoms, vision-related function, and environmental triggers. Patients rate their responses on a 0 to 4 scale with 0 corresponding to none of the time and 4 corresponding to all of the time. A final score is calculated which ranges from 0 to 100 with scores 0 to 12 representing normal, 13 to 22 representing mild dry eye disease, 23 to 32 representing moderate dry eye disease, and greater than 33 representing severe dry eye disease

Secondary

MeasureTime frameDescription
Change in Meibomian gland dysfunction GradingAt baseline (pre-intervention) and up to 4 weeks after treatment ends (after-intervention)Min = 0. Max =4. Low score: low Meibomian gland dysfunction (normal) High score: Meibomian gland dysfunction (pathology)
Change in Corneal StainingAt baseline (pre-intervention) and up to 4 weeks after treatment ends (after-intervention)We measure the amount of fluorescein dots (score 0 for 0 dots, score 1 for 1-5 dots, score 2 for 6-30 dots, score 3 for \>30 dots) Additional 1 point for - Patches of confluent staining Additional 1 point for - Staining in the pupillary area Additional 1 point for - One or more filament Min = 0. Max =6. Low score: Clear cornea (normal) High score: pathological cornea (pathology)
Change in Tear breakup timeAt baseline (pre-intervention) and up to 4 weeks after treatment ends (after-intervention)Measures the number of seconds for the fluorescein to break and thus assesses the stability of tear film. Min = 0. Max = 20. Low score: Tear film instability (pathology) High score: Normal Tear film stability (normal)
Change in Schirmer with anesthesiaAt baseline (pre-intervention) and up to 4 weeks after treatment ends (after-intervention)The Schirmer's test evaluates aqueous tear production. It is helpful in the assessment of patients with signs and/or symptoms of dry eye - as it can determine whether surface dryness is due to reduced tear production from the lacrimal glands as opposed to some other cause. The Schirmer basal secretion test was performed for each patient in both eyes in the following manner: Topical anesthetic was applied to the eye, and the conjunctival fornix was dried with a cotton tip applicator. After a 2-minute waiting period, the paper strip was folded and placed between the lower eyelid and the globe at the junction between the middle and lateral thirds of the eyelid. After 5 minutes, the filter paper is removed and the amount of wetting from the fold is measured (mm) We used the standard (no. 41 Whatman) filter paper. Min = 0 mm Max = 30 mm Low score: Low tear secretion (pathology) High score: Normal tear secretion (normal)
Change in Corrected visual acuityAt baseline (pre-intervention) and up to 4 weeks after treatment ends (after-intervention)LogMAR scale. Min = 0. Max = 1. Low score: Normal visual acuity (normal) High score: Imparied visual acuity (pathology)

Countries

Israel

Contacts

Primary ContactAsaf Shemer, MD
ShemerasafMD@gmail.com+972-8-9779620
Backup ContactAdi Einan
ADI.einan@gmail.com+972-8-9779620

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026