Detachable String Magnetically Controlled Capsule Endoscopy for Follow-up of Patients With Esophageal Diseases

Accuracy of Detachable String Magnetically Controlled Capsule Endoscopy for Follow-up of Patients With Esophageal Diseases: A Multicenter Study

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05469152
Enrollment
310
Registered
2022-07-21
Start date
2019-07-15
Completion date
2022-09-15
Last updated
2022-07-21

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Esophageal Diseases

Keywords

esophageal diseases, capsule endoscopy

Brief summary

The purpose of the study is to determine the accuracy of detachable string magnetically controlled capsule endoscopy(DS-MCE) as a follow-up method for patients with previous esophageal diseases.

Detailed description

Esophagogastroduodenoscopy (EGD) is recognized as the gold standard for detection and follow-up of esophageal diseases,allowing for direct mucosal visualization and therapeutic intervention. EGD is however an invasive procedure and there is potential for procedure-related complications, such as perforation and bleeding.Esophageal capsule endoscopy(ECE)provides a novel noninvasive approach to visualize the esophagus.The main drawback for the use of ECE is its unreliable transit time which often renders an inadequate visualization of the esophagus.Thus investigators have developed the detachable string magnetically controlled capsule endoscopy(DS-MCE) which can control the movement of the capsule through the string. The ds-MCE system consists of two parts: the magnetically controlled capsule endoscopy (MCE) system and a transparent latex sleeve with a hollow string. The magnetically controlled capsule endoscopy (MCE) system (Ankon Technologies, Shanghai, China) detects focal lesions in the stomach with comparable accuracy with conventional EGD. One end of the hollow string is a transparent thin latex sleeve that can be wrapped on the surface of the capsule, and the other end of the string is connected to the syringe. The capsule, which is partially enclosed within the sleeve, can be actively moved in the esophagus through the control of string. In this case, investigator can examine the entire esophageal mucosa several times under real time views. The capsule then could be detached from the string system through injecting air into the hollow string with the syringe after completing the examination of esophagus. The pilot study of ds-MCE confirmed it was a feasible, safe and well-tolerated method for completely viewing esophagus and stomach, without the need for sedation. Besides, the 8-10h battery life of the ds-MCE enables complete examination of the small bowel, which provides the possibility for screening pathological changes in the entire gastrointestinal tract. This study is a prospective, multi-centered, diagnostic accuracy study. The primary outcome is the diagnostic accuracy of ds-MCE in identifying esophageal diseases. Second outcomes include the visualization and cleanliness of Z-line, safety and patient satisfaction of DS-MCE.

Interventions

DIAGNOSTIC_TESTds-MCE and EGD

Procedure of ds-MCE: The ds-MCE system mainly consists of two parts: the NaviCam magnetic capsule endoscopy guidance system and the detachable string part. The capsule, which is partially enclosed within the sleeve, can be actively moved in the esophagus through the control of string. Investigator can examine the entire esophagus several times under real time views. The capsule then could be detached from the string system through injecting air into the hollow string with the syringe after completing the examination of esophagus. Then, the examination of stomach under magnetic control and small bowel under the natural action of peristalsis follows. Procedure of EGD: The EGD will be performed using conventional upper gastrointestinal video endoscopy, according to the standard procedure at individual centers. EGD will be performed within 48 hours after ds-MCE procedure and usually during the same endoscopic session.

Sponsors

Ruijin Hospital
CollaboratorOTHER
Shanghai Zhongshan Hospital
CollaboratorOTHER
XuHui District Central Hospital
CollaboratorUNKNOWN
Yangpu District Central Hospital Affiliated to Tongji University
CollaboratorOTHER
Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine
CollaboratorOTHER
Shanghai 6th People's Hospital
CollaboratorOTHER
Changhai Hospital
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 75 Years
Healthy volunteers
No

Inclusion criteria

1. Gender is not limited. 2. Patients aged between 18-75 years or older. 3. Both inpatients and outpatients. 4. Patients with previous esophageal diseases who are scheduled to undergo EGD for follow-up. 5. Able to provide informed consent.

Exclusion criteria

1. Patients aged less than 18 years. 2. Patients with active upper gastrointestinal bleeding. 3. Patients who have participated in or are participating in other clinical trials within three months. 4. Patients with cancer on active treatment with chemotherapy and/or radiation therapy. 5. Pregnancy or suspected pregnancy. 6. Suspected or known intestinal stenosis or other known risk factors for capsule retention. 7. Pacemaker or other implanted electromedical devices which could interfere with magnetic resonance. 8. Patients with dysphagia.

Design outcomes

Primary

MeasureTime frameDescription
The diagnostic accuracy of the ds-MCE in identifying esophageal diseases in comparison to standardized EGD2 weeksTo assess the diagnostic accuracy of the ds-MCE as a follow-up method for patients with previous esophageal diseases, using EGD as the gold standard.

Secondary

MeasureTime frameDescription
Number of quadrants visualized at Z-line by ds-MCE2 weeksTo assess the visualization of Z-line. Circumferential visualization of the Z line by ds-MCE was defined by quadrants as follows: Z line not observed at all; less than 2 quadrants (\< 50 %) of the Z line observed; between 2 quadrants and 3 quadrants (50 % - 75%) observed; more than 3 quadrants (\> 75%) observed; and entire Z line (100 %) observed.
Scores of cleanliness of Z-line area2 weeksThe effect of bubbles/saliva on the appearance of the Z line area was scored as follows: 0 = no interference by bubbles/saliva on the Z line area; 1 = minor interference of bubbles/saliva on the Z line area; 2 = major interference of bubbles/saliva on the Z line area.
Number of ds-MCE associated adverse events2 weeksTo assess the safety of ds-MCE.
The patient satisfaction of the ds-MCE through questionnaires2 weeksTo assess the patient satisfaction of the ds-MCE compared to standard EGD.